Soliwave FQR57
Technical Data
ComparePoint Level / Solids
| Measuring Principle | Microwave barrier |
| Characteristic / Application | Transmitter Non-contact point level detection and flow monitoring Detecting, counting and positioning of objects Monitoring of material transfer points Detection and analysis of deposits and contamination Non-contact installation: Waves emitted from outside Within installation: Waves emitted within installation (contact) |
| Specialities | With optional integrated bulk flow monitoring Parallel mode with up to 5 channels Detection range limit: max. 100 m Detection range flow: max. 10 m, depending on bulk solids |
| Supply / Communication | Via process transmitter with control unit Nivotester FTR525 |
| Ambient temperature | -40°C...+70°C (-40°F...+158°F) |
| Process temperature | Non-contact installation: any Within installation: -40°C...+70°C (-40°F...+158°F) With high temperature adapter: up to +450°C (+842°F) |
| Process pressure / max. overpressure limit | Non-contact installation: any Within installation: 0.5 bar...6.8 bar (7.2 psi ... 99 psi) abs. With high pressure adapter: up to +21 bar (+305 psi) abs. |
| Min. density of medium | Solid weight: > 10 g/l |
| Main wetted parts | Non-contact installation: No wetted parts Within installation: 316Ti, PTFE or Ceramic |
| Process connection | Threads: 1-1/2" R, 1-1/2" G, 1-1/2" NPT |
| Communication | Via process transmitter with control unit Nivotester FTR525 |
| Certificates / Approvals | ATEX, IEC Ex |
| Design approvals | EN10204-3.1 |
| Options | Sight glass High temperature adapter High pressure adapter Installation bracket FAR50, FAR51, FAR52, FAR53, FAR54, FAR55 |
| Components | Transceiver: FDR57 Process transmitter: FTR525 |
| Application limits | Solid weight: < 10 g/l |
The Soliwave microwave limit switch performs non-contact limit detection and flow monitoring of bulk solids (no-flow/flow, flow trend). The instrument can be used for detection and counting, detecting deposits and monitoring the feeding process and the quantity of material conveyed. It can be installed in vessels, channels, stockpiles, feed stations, pump stations, filters or other free-fall shafts of all kinds. Measurement outside non-metallic vessels is permitted.
Benefits
Convenient installation via R 1½, 1½ NPT thread or G 1½ (with lock nut)
The instrument is robust and operates economically throughout its entire lifecycle: wear-free, ceramic sensor membrane (optional) for the process-wetted part, long service life, maintenance-free
Optional integrated bulk solids flow monitoring increases the safety of limit detection
The measuring principle is virtually unaffected by process properties
Can be used in demanding conditions where other measuring methods are limited
Simple operation via the Nivotester FTR525 with graphic display saves time and costs
Applications
Non-contact (wear-free, maintenance-free) limit detection (low/high limit) and flow monitoring (no-flow/flow, flow trend) of bulk solids.
Detection, counting and positioning functions
Detection and analysis of deposits and contaminants in filters
Monitoring of the feeding process
Monitoring of the quantity of material conveyed
For use at temperatures up to 450°C (+842°F)
For use at pressures up to 20 bar (+290 psi)
International explosion-protection approval
E+H Product Model Configuration Tool
Please enter the product model to configure
Product comparison
Please enter the product models to compare in the fields below; up to three products can be compared
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Source: Endress+Hauserpublic information from the website
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Microwave Level Switch Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Microwave Level Switch.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Microwave Level Switch for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Microwave Level Switch Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Microwave Level Switch.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Microwave Level Switch for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Microwave Level Switch Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Microwave Level Switch.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Microwave Level Switch for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Microwave Level Switch Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Microwave Level Switch.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Microwave Level Switch for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.