Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

NMT81 罐区温度计

NMT81 罐区温度计

Prothermo NMT81

Prothermo NMT81 measures the average temperature of a medium and can optionally identify the water level. With an optional 2m long capacitance sensor, the water level is measured continuously delivering current water level information at any time. With its highly precise average temperature measurement, the NMT81 is perfectly suitable for custody transfer and inventory monitoring together with tank gauging such as Proservo NMS80, NMS81, NMS83, Micropilot NMR81, NMR84 and TankSideMonitor NRF81.
Compare

Thermometer

Measuring Principle Resistance Temperature Detector
Characteristic / Application High precision average temperature measurement up to 100 m (328 ft),
Options:
- Display
- Sensor probe height adjustment
- Heartbeat Verification + Monitoring
Max. immersion length on request up to 100 m (328 ft)
Process connection Flange:
DN50...DN80,
ASME 2"...4",
JIS 10K
Threads:
3/4"
MNPT2
M20
Operating temperature range Options:
-40 °C...+75 °C
(-40 °F...+167 °F)
-40 °C...+100 °C
(-40 °F...+212 °F)
-55 °C...+235 °C
(-67 °F...+455 °F)
-196 °C...+100 °C
(-321 °F...+212 °F)
Accuracy +/- 0.032 °C (+/- 0.058 °F)
Ex - approvals ATEX, IEC Ex, JPN Ex, UK Ex
Certification Metrological approvals and certifications: NMi, PTB
Calibration performed on accredited calibration facilities (acc. to ISO/ IEC 17025)

Average temperature thermometer Prothermo NMT81, high-precision average temperature measurement

Benefits

  • Up to 24 resistance thermometers can be installed for precise asset management

  • Corrosion-resistant wetted parts

  • Installation opening of only 1-1/4”, minimizing tank manufacturing costs

  • Simple installation

  • Watertight and dustproof housing

  • Redundant resistance thermometer measurement via software algorithms, reducing downtime

 

Applications

The Prothermo NMT81 is used for average temperature measurement of the medium, with an optional level monitoring function. The instrument has a built-in 2-meter capacitive sensor that continuously measures the level and can output the current level information at any time. The NMT81 high-precision average temperature thermometer, used together with tank gauging instruments (e.g., servo level gauges Proservo NMS80, NMS81 and NMS 83; radar level gauges Micropilot NMR81 and NMR84; and tank-side indicator NRF81), is the ideal choice for custody transfer and inventory monitoring applications. 

  • High-precision average temperature measurement and water bottom level measurement

  • Process connection: flange (nominal size not less than 1-1/4“)

  • Temperature range: -40...+60°C (-40...+140°F)

  • Measuring height: 100 m (328.08 ft)

  • Overall accuracy: ±0.032°C (±0.06°F) with 5-point temperature calibration

  • Conversion accuracy (temperature): ±0.025°C (0.045°F)

  • Sensor measurement accuracy: ±0.02°C (0.036°F)

 

 

E+H product configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products to compare in the fields below. Up to three products can be compared.

 

Technical documentation

   

Technical data

 

 

   

Documents/Manuals/Software

 

 

   

Accessories/Spare parts

 

 

Source: Endress+Hauser public information from the website

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · RTD Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of RTD.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · RTD Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of RTD.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · RTD Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of RTD.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · RTD Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of RTD.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.