Sensor OUSAF11
Technical Data
CompareConcentration
| Measuring Principle | NIR absorbance |
| Application | Suspended solids measurement, product interface detection, milk detection, produkt loss detection |
| Characteristic | VIS/NIR absorption |
| Measuring range | 0 to 3 AU 0 to 6 OD (depending on optical path length) |
| Design | Glassfree, hygienic sensor |
| Material | Sensor head: FEP Sensor body: stainless steel 316L O-Ring: EPDM |
| Process temperature | 0 to 90 °C (32 to 194 °F) continuous Max. 130 °C (266 °F) for 2 hours |
| Process pressure | Max. 10 bar abs at 20 °C (Max. 150 psi at 68 °F) |
| Connection | Thread G1 NPT 1" thread Tri-Clamp 2"/2.5"/3" VARIVENT N DN40-125 |
| Ingress protection | IP 67 IP 68 when mounted with CYH112 |
| Certificates, declarations and approvals | FDA, 3-A |
The OUSAF11 is a non-glass sensor for online monitoring of phase changes and suspended solids. When inserted into a pipe or vessel, it reduces your product loss and ensures product purity. You can also use it as an immersion electrode in open basins and channels for efficient wastewater monitoring. Its non-glass, hygienic design guarantees maximum safety of your product. The OUSAF11 can be used in high-temperature and aggressive media and is suitable for all industries.
Benefits
Non-glass hygienic design for maximum media safety
Fast interface detection saves time and reduces media loss
Low sensor maintenance, long service life and stable operation
Flexible sensor installation: insertion (with Tri-Clamp or Varivent connections) and immersion (with CYA112 and CYH112 holders)
Robust sensor housing, resistant to chemical corrosion and contamination
Resistant to CIP and SIP cleaning
FDA and 3-A approval
Applications
The OUSAF11 sensor is used to detect phase separation and suspended solids in the following industries:
Food & beverage:
- Milk detection in CIP processes
- Phase separation detection in dairies and breweries
- Product loss detection in wastewater discharge
Primary industry, mining and metallurgy:
- Suspended solids measurement
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Turbidity Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Turbidity.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Turbidity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Turbidity Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Turbidity.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Turbidity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Turbidity Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Turbidity.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Turbidity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Turbidity Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Turbidity.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Turbidity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Related Products
Endress+HauserTurbimax CUS52D
Endress+HauserTurbimax CUS51D
Endress+HauserTurbimax CUS71D
Endress+HauserTurbimax CUS50D
Endress+HauserTurbimax CUE22, compact white light
Endress+HauserTurbimax CUE21, compact infrared
Endress+HauserFlowfit CUA252
Endress+Hauser