Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

PMP23 pressure transmitter

PMP23 pressure transmitter

Cerabar PMP23

Configurable Models 11 models
The economical pressure transmitter adopts an integral welded structure, suitable for the food and beverage industry
Compare

Continuous / Liquids

Measuring Principle Absolute and gauge pressure
Characteristic / Application Cost-effective pressure transducer, piezoresistive sensor with metallic measuring diaphragm for hygienic applications
Supply / Communication 10…30 VDC
Accuracy 0.3%
Long term stability 0.2% of URL/year
Ambient temperature -40…+85°C
(-40…+185°F)
Process temperature -10…+100°C
(+14…+212°F)
135°C for 1h
(275°F for 1h)
Process pressure / max. overpressure limit 160 bar (2400 psi)
Pressure measuring range 400 mbar…+40 bar
(6...+600psi)
Process connection Thread:
G1, M24
Process connection hygienic DIN11851,
Clamp,
SMS,
Varivent,
Universal adapter
Communication 4...20 mA
IO- Link
Certificates / Approvals ATEX, FM, CSA, IEC Ex, NEPSI, UK Ex
Design approvals EN 10204-3.1
Final inspection report
Cleaned from oil + grease
Surface roughness measurement
Hygienic approvals 3A, EHEDG
EG1935/ 2004

Pressure

Measuring Principle Absolute and gauge pressure
Characteristic Cost-effective pressure transducer, piezoresistive sensor with metallic measuring diaphragm for hygienic applications
Supply voltage 10…30 VDC
Reference Accuracy 0.3 %
Long term stability 0.2 % of URL/year
Process temperature -10 °C…+100 °C
(+14 °F…+212 °F)
+135 °C for 1 h
(+275 °F for 1 h)
Ambient temperature -40 °C…+85 °C
(-40 °F…+185 °F)
Measuring cell +400 mbar…+40 bar
(+6 psi...+600 psi)
Max. overpressure limit 160 bar (2400 psi)
Process connection Threads:
G1, M24
Process connection hygienic DIN11851,
Clamp,
SMS,
Varivent,
Universal adapter
Communication 4...20 mA
IO- Link
Certificates / Approvals ATEX, FM, CSA, IEC Ex, NEPSI, UK Ex
Design approvals EN 10204-3.1Final inspection report
Cleaned from oil + grease
Surface roughness measurement
Hygienic approvals 3A, EHEDG
EG1935/ 2004

The Cerabar PMP23 is a cost-effective, compact absolute or gauge pressure transmitter. The piezoresistive sensor with flush-mounted 316L diaphragm meets the requirements of hygienic applications. The PMP23 is available with various EHEDG and 3-A hygienic process connections, uses FDA-listed materials, complies with EC 1935/2004, has IP69 degree of protection, optional IO-Link and explosion protection approval. Devices with customer-specific measuring ranges can be ordered, up to a maximum of 40 bar.

Benefits:

  • Ultra-compact design with user-definable measuring ranges for simple, time-saving installation and setup of the instrument in the plant

  • IO-Link enables easy configuration with simple configuration tools or engineering systems, reducing cost and complexity

  • No gaskets required; the all-welded process connection provides the highest process safety

  • Made entirely of 316L for process suitability; instrument versions with IP69 protection meet washdown requirements, with high repeatability and long-term stability

  • Flexible use and low inventory costs; the PMP23 withstands CIP/SIP cleaning

  • The PMP23 meets the requirements for hygienic documentation and device traceability, e.g.: EHEDG approval, 3-A approval or Regulation (EC) 1935/2004, relevant certificates, and the manufacturer's declaration of conformity

Application areas:

The pressure transmitter measures the absolute or gauge pressure of gases or liquids.

  • Process connection: flush hygienic connection, flush threaded connection

  • Process temperature: -10...+100 °C (-40...+212 °F); +135 °C (+275 °F), max. 1 h

  • Process pressure: 400 mbar...+40 bar (6...600 psi)

  • Measuring accuracy: ±0.3 % of full scale

  • International explosion protection approval, hygienic approval

 

E+H product model configurator

Please enter the product model to configure

Product comparison

Please enter the product models to be compared in the input boxes below; up to three products can be compared

 

   

Technical information

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source: public information from the Endress+Hauser website

Model Name
PMP23-AA1M1KB3AJ 压力变送器
PMP23-BA1M1HB3CJ 压力变送器
PMP23-AA1M1PB3EJ 压力变送器
PMP23-AA1U1MBWSJ 压力变送器
PMP23-BA1M2HB3CJ 压力变送器
PMP23-BA1U1HB1GJ 压力变送器
PMP23-AA1V1MBWSJ 压力变送器
PMP23-AA1M1PBWSJ 压力变送器
PMP23-AA1M1PB3CJ 压力变送器
PMP23-AA1M1QB3CJ 压力变送器
PMP23-CA1N2KB3CJ 压力变送器
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Gauge and Absolute Pressure Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Gauge and Absolute Pressure.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Gauge and Absolute Pressure for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Gauge and Absolute Pressure Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Gauge and Absolute Pressure.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Gauge and Absolute Pressure for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Gauge and Absolute Pressure Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Gauge and Absolute Pressure.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Gauge and Absolute Pressure for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Gauge and Absolute Pressure Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Gauge and Absolute Pressure.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Gauge and Absolute Pressure for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.