Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

RH33 能量积算仪

RH33 能量积算仪

EngyCal RH33

Configurable Models 20 models
The BTU meter RH33 is used in applications with liquid energy carriers. It calculates the thermal energy of water acc. to EN1434, glycol/water mixtures or other fluids such as thermal oils. Temperature sensor matching using calibrated temperature sensors is done in the device. Potential for cost savings can be shown by using the software available as an accessory. The device has a custody transfer approval and allows bi-directional measurement, e.g. charging/discharging of a heat accumulator.
Compare

Energy & Application Manager

Measuring Principle Energy manager
Measuring principle Energy manager
Function Monitoring and billing of energy in heating and cooling applications as well as combined heating-and cooling circles.
Typical applications can be found in industries, district heating and building automation.
Calculations heat quantity and heat quantity difference
Number of applications 1
Calculation standards IAPWS-97
Communication web server
USB
Ethernet
Modbus RTU/TCP Slave
M-Bus
Power supply Not defined
Loop power supply Low voltage power supply:
100 bis 230 V AC (-15% / +10%)
Small voltage power supply:
24 V DC (-50% / +75%)
24 V AC (±50%)
Protection class IP65
Input 1x Puls/Analog
2x RTD/Analog
Loop power supply 24V DC (+/-16%)
Output 1x 4...20mA
2x digital (Open Collector)
Dimensions (WxHxD) 144 x 144 x 103.1 mm (5.67" x 5.67" x 4.06")
Operation 3 button on site or via FieldCare
read out of historical / logged data via Field Data Manager Software (SQL database and visualization interface)
selectable language
Display 160 x 80 Dot-Matrix LCD with white backlit
colour change in case of alarm event
active display area 70 x 34 mm
Software functions Calculated Values:
Energy, volume, density, enthalpy & enthalpy difference, DP-Flow-Compensation, mass, temperature difference
Counters:
Volume, mass, energy, counter in case of failure
Optional:
tariff 1, tariff 2 or seperated heating energy, cooling energy, bilance energy
Certificates CSA GP
MID 004 (custody transfer) according EN1434 (water/other liquids)
OIML R75
Non-hazardous area + KC marking

Thermal Energy Measurement

Measuring Principle Energy manager
Function Monitoring and billing of energy in heating and cooling applications as well as combined heating-and cooling circles.
Typical applications can be found in industries, district heating and building automation.
Certification CE, UL listed, CSA GP, MID 004 (custody transfer) according EN1434 (water/other liquids) and OIML R75
Input 1x Puls/Analog,
2x RTD/Analog,
Loop power supply 24V DC (+/-16%)
Output 1x 4...20mA,
2x digital (Open Collector)
Relay output 2x
Auxiliary power supply Low voltage power supply: 100 bis 230 V AC (-15% / +10%); Small voltage power supply: 24 V DC (-50% / +75%), 24 V AC (±50%)
Dimensions (wxhxd) 144 x 144 x 103.1 mm
(5.67" x 5.67" x 4.06")
Software Calculated Values:
Energy, volume, density, enthalpy & enthalpy difference,
DP-Flow-Compensation,
mass,
temperature difference;
Counters: volume, mass, energy, counter in case of failure
Optional: tariff 1, tariff 2 or seperated heating energy, cooling energy, bilance energy
Operation 3 button on site or via FieldCare; read out of historical / logged data via Field Data Manager Software (SQL database and visualization interface), selectable language
Display 160 x 80 Dot-Matrix LCD with white backlit, colour change in case of alarm event, active display area 70 x 34 mm
Others electronic temperature sensor matching via CvD coefficients, logbook measured values, custody transfer logbook, event logbook, limit monitoring
Calculations IAPWS-IF97

The RH33 BTU meter is suitable for metering liquid energy carriers and calculates the thermal energy of water, water/glycol mixtures or other liquids such as thermal oil according to EN1434. Temperature sensor matching is carried out in the device using calibrated temperature sensors. Existing software is used to save costs. The device is approved for custody transfer and allows bidirectional measurement, for example the charging/discharging of a heat accumulator.

 

Advantages

Transparent energy consumption helps save energy costs

Calibrated, electronically paired temperature sensors ensure the highest accuracy; temperature sensors of approved devices can be replaced on site (without re-approval)

The tariff calculator meets billing requirements

Detailed data log recording current values and counter values, error messages, and inhibit conditions and changes of operating parameters

The standard mode connects and serves all common volume flow transmitters and temperature measuring points

Values can be read remotely via Ethernet and fieldbus

Reliability and accuracy verified and certified

 

Areas of application

For custody transfer of heat changes in the following circuits:

 

Heating circuits

Cooling circuits

Combined heating and cooling circuits

Typical applications in industry, long-distance heating networks and building automation.

 

 

E+H Product Configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products to compare in the boxes below (up to three products)

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source:Endress+Hauserwebsite public information

Model Name
RH33-AA1A+AAB1D2 能量积算仪
RH33-UR2B+B1D1 能量积算仪
RH33-AA1B+B1D2 能量积算仪
RH33-CP2B+B1D1 能量积算仪
RH33-CP1B+B1D2 能量积算仪
RH33-UR2B 能量积算仪
RH33-UR2A 能量积算仪
RH33-CP1B+B1D1 能量积算仪
RH33-UR2A+B1D2 能量积算仪
RH33-UR2A+B1D1 能量积算仪
RH33-AA2A+B1D2 能量积算仪
RH33-CP2A+B1D1 能量积算仪
RH33-CP1B 能量积算仪
RH33-UR1B+B1D2 能量积算仪
RH33-UR1A+B1D1 能量积算仪
RH33-UR1A+B1D2 能量积算仪
RH33-CP2A 能量积算仪
RH33-UR1A+B1 能量积算仪
RH33-AA2B+B1 能量积算仪
RH33-CP1A 能量积算仪
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Data Manager Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Data Manager.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Data Manager for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Data Manager Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Data Manager.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Data Manager for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Data Manager Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Data Manager.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Data Manager for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Data Manager Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Data Manager.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Data Manager for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.