Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

SFG600 网关

SFG600 网关

网关

The Fieldgate PAM SFG600 is a device configuration management gateway and supports HART devices via PROFINET networks. The HART devices must have a unique device TAG. The devices must be in operation with a PROFINET controller and operated via the Siemens assembly ET 200SP with the 4xl 2-wire HART analog modules with HART capabilities. During production, the Fieldgate is configured with the IP address supplied by the customer at the field network interface, and connected to the PROFINET.
Compare

Fieldbus components

Measuring Principle
Function Device configuration management gateway supports HART devices via PROFINET networks
CPU Intel Core i5 processor 7300U 2.6 GHz Dual Core
Memory SO-DIMM DDR4, 8192 MByte
Hard disk drive CFast 64 GByte MLC
Power supply 24 VDC ±25 %, SELV
Dimensions (WxHxD) 221.5 mm x 54 mm x 248.3 mm (8.72 " x 2.12" x 9.77")
Communication interface 1x Ethernet PROFINET RJ45 (ETH1)
1x Ethernet PAM Client RJ45 (ETH2)
1x Ethernet service RJ45 (IF Option 2)
System requirements PROFINET remote I/Os
Siemens ET200SP IM155-6PN HF
Order code: 6ES7 155-6AU00-0CN0
HART module with Siemens ET200SP IM 155-6PN HF
Module 4xI 2-wire HART
Order code: 6ES7 134-6TD00-0CA1
Certificates CE mark
UL
CCC

The Fieldgate PAM SFG600 is a device configuration management gateway that supports HART devices in PROFINET networks. Each HART device must use a unique device tag. The devices must be used together with a PROFINET controller and operated via a Siemens ET 200SP with four two-wire HART analog inputs. The Fieldgate is delivered with its IP address set to the address of the user's on-site network interface and is already connected to PROFINET.

Benefits
Industrially robust Fieldgate delivered fully configured.
Plug and play, simple wiring.
Fully automatic network scan of all HART devices connected to the Siemens ET 200SP in the PROFINET system, largely unaffected by network complexity.
When used with the Field Xpert SMT70 tablet, devices connect directly to the tablet as if they were right in front of you, even in large plants.
When used with the Field Xpert SMT70 tablet, it is the only open, FDT-based PAM system for configuring HART devices in PROFINET systems via the Siemens ET 200SP HART remote I/O interface (fully open).
Allows access for a remote maintenance team of up to 10 people, with up to 1024 devices connectable per PROFINET segment coupler in the system.

Application areas
The Fieldgate PAM SFG600 enables configuration of HART devices in PROFINET systems via the Siemens ET 200SP HART remote I/O interface. The Field Xpert SMT70 can connect up to 10 users and 1024 devices, quickly and simply, without scanning or network configuration.
 

   

Technical Documentation

   

Technical Specifications

 

 

Documents/Manuals/Software

 

 

Accessories/Spare Parts

 

Source:Endress+Hauserwebsite public information

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Gateways and Modems Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Gateways and Modems.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Gateways and Modems for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Gateways and Modems Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Gateways and Modems.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Gateways and Modems for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Gateways and Modems Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Gateways and Modems.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Gateways and Modems for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Gateways and Modems Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Gateways and Modems.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Gateways and Modems for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.