Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

T15 防爆型热电阻(RTD)温度计(US型)

T15  防爆型热电阻(RTD)温度计(US型)

防爆型热电阻()温度计(型)

The robust device is a unit ready for use within and existing thermowell and includes various housing transmitter heads to meet the application and space requirement needs. The unit offers enhanced measurement accuracy and reliability. A variety of connections, dimensions and materials (like 316L SS and Hastelloy C276) offer flexible application possibilities.
Compare

Thermometer

Measuring Principle Resistance Temperature Detector
Characteristic / Application Explosion Proof US style
modular temperature assembly
for heavy duty applications
with extension
to be used with existing thermowell
Thermowell / protection tube to be used with thermowell
Insert / probe mineral insulated (MI), flexible
PTFE-insulated, rigid
Outer diameter protection tube / Insert Not applicable
Max. immersion length on request up to 100" (2540 mm)
others on request
Material protection tube/ thermowell Sensor sheath
316/316L
Optional coating Not defined
Process connection male thread:
NPT1/2"
Tip shape straight
Surface roughness Ra Not defined
Operating temperature range PT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F)
Max. process pressure (static) Not applicable
Accuracy class A acc. to IEC 60751
class B acc. to IEC 60751
Response time 63% rt = 3 s
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals FM XP DIP
FM XP NI DIP
CSA XP DIP
CSA XP NI DIP
FM/CSA XP DIP
FM/CSA XP NI DIP
CSA C/US XP, DIP
cCSAus General Purpose
Certification SIL (transmitter only)

The robust thermometer consists of a protection tube and a connection head that can be fitted with different transmitter types to meet different application environments and space requirements. The thermometer offers high measuring accuracy and reliability and is available with various process connections, dimensions and materials (e.g. 316L SS and Hastelloy C276) for flexible use in a wide range of applications.


Advantages
FM/CSA XP Cl. I, Div. 1 certified thermometer with the highest safety
One-stop temperature measurement solution. First-class transmitter with integrated sensor for demanding industrial process applications.
Install and use directly after unpacking
Improved electrical isolation (2 kV) when installed on most devices
Simple modular structure: excellent value for money. Easy ordering and reordering. The complete unit with sensor, thermowell and transmitter provides a complete measuring point solution
Long-term stability of all iTEMP® transmitters ≤ 0.05 %/year


Application
T15 is a resistance thermometer (RTD) installed in a thermowell, certified by FM and CSA, and can be used under harsh conditions and in hazardous areas. The sensor consists of an insulated resistance (RTD) measuring probe and a mineral-insulated insert.
The sensor can be used in the following process industries, e.g.:
Chemical industry
Petrochemical industry
Refineries
Offshore platforms

 

E+H Product Configurator

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the boxes below (max. three products)

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source:Endress+Hauserwebsite public information

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · RTD Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of RTD.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · RTD Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of RTD.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · RTD Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of RTD.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · RTD Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of RTD.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.