Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

TH13 模块化热电阻(RTD)温度计(US型)

TH13   模块化热电阻(RTD)温度计(US型)

RTD Assembly TH13, TW type US Style

The robust device with a barstock thermowell is a complete unit ready for use with various housing transmitter heads to meet the application and space requirement needs. The unit offers enhanced measurement accuracy and reliability. A variety of process connections, dimensions, and materials (like 316L SS and Hastelloy C276) offer flexible application possibilities.
Compare

Thermometer

Measuring Principle Resistance Temperature Detector
Characteristic / Application US style
modular temperature assembly
threaded process connection
process connection as weld in version
with extension
incl. thermowell
Thermowell / protection tube bar stock (drilled)
Insert / probe mineral insulated (MI), flexible
PTFE-insulated, rigid
Outer diameter protection tube / Insert 3/4'' (19,05 mm)
1'' (25,40 mm)
17/16'' (26,99 mm)
15,88 mm ...33,40 mm
(0,63'' ...1,31'')
Max. immersion length on request up to 24" (609 mm)
others on request
Material protection tube/ thermowell 316/316L
A105
AlloyC276
others on request
Optional coating Available on request
Process connection male thread:
NPT1/2"
NPT3/4"
NPT1"
weld in version
socket weld version
1"
Tip shape reduced
tapered
straight
Surface roughness Ra 32 μin (0.80 μm)
Operating temperature range PT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
iTHERM StrongSens:
-50 °C … 500 °C
(-58 °F … 932 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F)
Max. process pressure (static) at 20 °C: 100 bar (1.450 psi)
depends on configuration
Accuracy class AA acc. to IEC 60751
class A acc. to IEC 60751
class B acc. to IEC 60751
Response time depending on configuration
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals transmitter only
FM IS
CSA IS
FM/CSA IS
Certification SIL (transmitter only)

The bar stock thermowell thermometer is robust and durable and can form a complete unit with a connection head fitted with a transmitter to meet different application environments and space requirements. The thermometer offers high measuring accuracy and reliability and is available with various process connections, dimensions and materials (e.g. 316L SS and Hastelloy C276) for flexible use in a wide range of applications.


Advantages
Modular thermometer with standard connection head and user-defined insertion depth for flexible use
One-stop temperature measurement solution. First-class transmitter with integrated sensor for demanding industrial process applications. Install and use directly after unpacking
Improved electrical isolation (2 kV) when installed on most devices
Simple modular structure: excellent value for money. Easy ordering and reordering. The complete unit with sensor and transmitter provides a complete measuring point solution
Long-term stability of all iTEMP® transmitters ≤ 0.05 %/year
Stepped/tapered tip for a short response time
Simple selection of modular transmitter: 4...20 mA analog output, HART®, PROFIBUS® PA or FOUNDATION Fieldbus (FF™)


Application
TH13 is a resistance thermometer (RTD) installed in a thermowell, with a robust structure suitable for various industrial processes including harsh conditions. It contains a measuring probe with insulated resistance (RTD) element, a mineral-insulated insert and a bar stock thermowell.
The sensor is suitable for the following industries:
Chemical industry
Petrochemical industry
Power plants
Refineries
Offshore platforms

 

E+H Product Configurator

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the boxes below (max. three products)

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source:Endress+Hauserwebsite public information

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · RTD Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of RTD.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · RTD Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of RTD.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · RTD Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of RTD.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · RTD Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of RTD.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.