Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

TR61 热电阻温度计

TR61 热电阻温度计

RTD Thermometer TR61

The robust thermometer is designed for use in demanding and safety relevant applications e.g. in the Chemical, Oil & Gas and Energy industry. Harsh environments, corrosive substances and highest pressures can be handled by the use of robust protection tubes and special materials. An optional head transmitter with all common communication protocols makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. Flexible configuration possible.
Compare

Thermometer

Measuring Principle
Characteristic / Application metric style
modular temperature assembly
for heavy duty applications
suitable for hazardous areas
with neck
incl. thermowell / protection tube (metal)
usable with insert StrongSens
Thermowell / protection tube welded protection tube
Insert / probe mineral insulated (MI), flexible
Outer diameter protection tube / Insert 9,0 mm (0,35'')
11,0 mm (0,43'')
12,0 mm (0,47'')
Max. immersion length on request up to 10.000,00 mm (393,70'')
Material protection tube/ thermowell 1.4404 (316L)
1.4571 (316Ti)
AlloyC276 (2.4819)
Optional coating Not defined
Process connection male thread:
G1/2"
G3/4"
G1"
NPT1/2"
NPT3/4"
M20x1,5
compression fitting:
G1/2"
flange:
ASME 1" 150 RF (B16.5)
ASME 1" 300 RF (B16.5)
DN25 PN40 B1 (EN1092)
DN40 PN40 B1(EN1092)
DN50 PN40 B1 (EN1092)
Tip shape straight
reduced
tapered
Surface roughness Ra Not defined
Operating temperature range PT100 TF StrongSens:
-50 °C ...500 °C
(-58 °F ...932 °F)
PT100 WW:
-200 °C ...600 °C
(-328 °F ...1.112 °F)
PT100 TF:
-50 °C ...400 °C
(-58 °F ...752 °F)
Max. process pressure (static) at 20 °C: 100 bar (1.450 psi)
Accuracy class A acc. to IEC 60751
class AA acc. to IEC 60751
Response time depending on configuration
t50 = 8 s
t90 = 21 s
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals ATEX II1/2D Ex ia IIIC,II1G Ex ia IIC T6
ATEX II 2 GD Ex d IIC
ATEX II 3 G Ex nA IIC T6, II3D
ATEX II 1/2 GD Ex d IIC
IECEx Ex d Ga/Gb IIC T6/T5/T4,Ex tD A20
IECEx Ex ia IIC T6 Ga/Gb
IECEx Ex d IIC T6/T5/T4
IECEx Ex d IIC T6/T5/T4, Ex tD A21
EAC Ex ia IIC T6 Ga + DIP
EAC Ex d IIC T6 Gb + DIP
NEPSI Ex ia IIC T6, Ex iaD 20 T85-T450
NEPSI Ex d IIC T6
NEPSI Ex nA IIC T6
Explosion proof
Certification Gost Metrology
SIL (transmitter only)

This thermometer is rugged and suitable for harsh conditions and high-safety measurement applications in the chemical, oil, gas and energy industries. The robust thermowell and special materials withstand harsh working environments, corrosive substances and high pressure. The optional transmitter is compatible with various common communication protocols and is ready to use; compared with directly wired sensors, it improves measuring accuracy and reliability, and the device setup is flexible.

Benefits:

Explosion protection types: intrinsically safe (Ex ia), flameproof (Ex d), non-sparking (Ex nA)

  • High insert compatibility, design in accordance with DIN 43772

  • Extension neck prevents transmitter overheating

  • Short taper/conical tip for faster response time

  • Modular design with a standard terminal head per DIN EN 50446 and customer-specified insertion depth for high flexibility

  •  

 

 

E+H product model configurator

Please enter the product model to configure

Product comparison

Please enter the product models to be compared in the input boxes below; up to three products can be compared

 

   

Technical information

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source: public information from the Endress+Hauser website

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · RTD Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of RTD.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · RTD Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of RTD.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · RTD Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of RTD.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · RTD Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of RTD.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.