RTD Thermometer TST434
Technical Data
CompareThermometer
| Measuring Principle | |
| Characteristic / Application | metric style probe for ambient temperature measurement without neck |
| Thermowell / protection tube | without (not intended to use with thermowell) |
| Outer diameter protection tube / Insert | 20,0 mm (0,79'') |
| Material protection tube/ thermowell | Aluminium |
| Operating temperature range | PT 100: -50 °C ...100 °C (-58 °F …212 °F) |
| Max. process pressure (static) | at 20 °C: 1 bar (15 psi) |
| Accuracy | class A acc. to IEC 60751 class B acc. to IEC 60751 |
| Integration head transmitter | yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS) |
| Certification | SIL (transmitter only) |
The specially designed platinum resistance (RTD) thermometer is mainly used for monitoring room temperature. Devices with a head-mounted transmitter are ready for immediate use and offer higher measuring accuracy and reliability than directly wired sensors, and can be used for indoor and outdoor ambient temperature measurement.
Benefits
Modular design with a standard terminal head conforming to DIN EN 50446 and customer-specific immersion length for high flexibility
Highly compatible insert, designed in accordance with DIN 43772
High accuracy and extremely long stability
Easy selection of the head transmitter: analog output 4 to 20 mA, HART®, PROFIBUS® PA or FF fieldbus
E+H Product Configurator
Please enter the product model to configure
Product Comparison
Please enter the product models to compare in the fields below. Up to three products can be compared
Technical Documentation
Technical Specifications
Documents/Manuals/Software
Accessories/Spare Parts
Source:Endress+Hauserwebsite public information
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · RTD Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of RTD.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · RTD Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of RTD.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · RTD Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of RTD.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · RTD Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of RTD.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Related Products
Endress+HauseriTHERM ModuLine TM101
Endress+HauseriTHERM ModuLine TM131
Endress+HauserRTD Thermometer TR10
Endress+HauseriTHERM ModuLine TM111
Endress+HauseriTHERM CompactLine TM311
Endress+HauserCompact Thermometer TMR31