Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

TST434B 室内热电阻温度计

TST434B 室内热电阻温度计

室内热电阻温度计

Endress+Hauser TST434B
Configurable Models 20 models
The iTHERM ModuLine TST434B RTD thermometer is specially designed for monitoring the room temperature in almost all industries. It is available as a complete unit including Endress+Hauser temperature transmitters for enhanced measurement accuracy and reliability compared to directly wired sensors. With a variety of common and advanced outputs and communication protocols, they offer easy customizing.
Compare

Thermometer

Measuring Principle Resistance Temperature Detector
Characteristic / Application probe for ambient temperature measurement
without neck
Thermowell / protection tube without (not intended to use with thermowell)
Outer diameter protection tube / Insert 20,0 mm (0,79'')
Material protection tube/ thermowell Aluminium
Operating temperature range PT 100:
-50 °C ...150 °C
(-58 °F ...302 °F)
Max. process pressure (static) at 20 °C: 1 bar (15 psi)
Accuracy class A acc. to IEC 60751
class B acc. to IEC 60751
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Certification SIL (transmitter only)

Field of application

The iTHERM ModuLine TST434B RTD thermometer is specially designed for monitoring room temperature in virtually all industries.
It is a complete unit including an Endress+Hauser temperature transmitter, offering increased measuring accuracy and reliability compared to directly wired sensors. Via various common and advanced output and communication protocols, they offer convenient customization.
Outdoor or indoor ambient temperature measurement
Maximum measuring range: -50 to +150°C (-58 to +302°F)
Degree of protection: IP66/68 (NEMA Type 4X housing)

 

Advantages
Robust terminal head complying with DIN EN 50446 or stable plastic housing provides optimum protection under extreme environmental conditions
Reliable, long-term stable and accurate indoor and outdoor ambient temperature measurement
Simple and fast wall mounting
Optional head transmitter: analog 4-20 mA, HART®, PROFIBUS®PA, FOUNDATION Fieldbus™, IO-Link, PROFINET® over Ethernet-APL/SPE

 

 

E+H product configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products you wish to compare in the fields below (up to three products)

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source:Endress+Hauserpublic information from the website

Model Name
TST434B-AAA3CBD 室内热电阻温度计
TST434B-AAC3DAB 室内热电阻温度计
TST434B-AAB5AAB 室内热电阻温度计
TST434B-AAC4ABA 室内热电阻温度计
TST434B-AAB6UBD 室内热电阻温度计
TST434B-AAB3DAB 室内热电阻温度计
TST434B-AAB3DBD 室内热电阻温度计
TST434B-AAC5ABD 室内热电阻温度计
TST434B-AAB5ABD 室内热电阻温度计
TST434B-AAB2IBD 室内热电阻温度计
TST434B-AAA4ABA 室内热电阻温度计
TST434B-AAB6BBD 室内热电阻温度计
TST434B-AAC6UBD 室内热电阻温度计
TST434B-AAB2IBC 室内热电阻温度计
TST434B-AAB3CBD 室内热电阻温度计
TST434B-AAC2HBA 室内热电阻温度计
TST434B-AAB4AAB 室内热电阻温度计
TST434B-AAA2CBA 室内热电阻温度计
TST434B-AAA2HBA 室内热电阻温度计
TST434B-AAC6BAB 室内热电阻温度计
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · RTD Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of RTD.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · RTD Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of RTD.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · RTD Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of RTD.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · RTD Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of RTD.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable RTD for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.