HQ30d single-input multi-parameter digital analyzer is a plug-and-play analyzer suitable for any IntelliCAL electrode. An analyzer can measure pH, conductivity and LDO; The electrode serial number can be automatically registered in the analyzer. Both the sample ID and the operator ID can be linked to the measurement and stored in the recorder for final traceability. The replacement of measurement parameters/electrodes is fast and convenient without recalibration. The factory calibrated IntelliCAL electrode can be used directly. The password protection function of data can ensure accurate and tamper-free reports; A 500 data logging function stores measurement results, calibrations and inspection standards.
technical parameters:
power supply: 4AA batteries; battery life:>200 hours, with AC/DC power connection
Single parameter display: can display readings from 1 electrode.
pH electrode: pH,mV, temperature
Conductivity electrode: selected parameters, temperature correction and temperature
LDO electrode: dissolved oxygen, pressure, temperature
Data Memory: 500 sets of data
Data storage: The calibration data is stored in a log. Automatic storage in "press-and-read" mode and interval measurement mode. In the "Lian
Manual storage is required for continuous reading mode.
Temperature correction/compensation: automatic Data logging: user selection interval
Lock display function: continuous measurement mode or press-and-read measurement mode has the function of averaging LDO measurement readings.
Automatic identification of pH buffers: Three options are available:
pH automatic identification function: can identify the pH of 4,7,10 standard solution
IUPAC: 1.679,4.005,7.000,10.012
DIN: 1.09,4.65,9.23
Water resistance: the tester shell can be soaked in water at a depth of 1 meter for 30 minutes (IP67)
Ordering Information:
HQ30d53000000 HQ30d Single Input Multi-parameter Digital Analyzer Host
HQ30d5330100 HQ30d host, standard LDO dissolved oxygen probe, 1m cable
HQ30d5330300 HQ30d host, standard LDO dissolved oxygen probe, 3m cable
8505100 HQ30d host, shock-resistant LDO dissolved oxygen probe, 5m cable
HQ30d53101000 HQ30d host, pHC10101 standard pH electrode, 1m cable
HQ30d53103000 HQ30d host, pHC10103 standard pH electrode, 3m cable
HQ30d53115000 HQ30d host, pHC10105 impact-resistant pH electrode, 5m cable
HQ30d53201000 HQ30d host, CDC40101 standard conductivity electrode, 1m cable
HQ30d53203000 HQ30d host, CDC40103 standard conductivity electrode, 3m cable
HQ30d53215000 HQ30d host, CDC40105 impact-resistant conductivity electrode, 5m cable
HQ30d53101201 HQ30d mainframe, PHC10103 standard pH electrode (1 m cable),CDC40103 standard conductivity electrode (1 m cable)
HQ30d53103203 HQ30d host, PHC10103 standard pH electrode (3 m cable),CDC40103 standard conductivity electrode (3 m cable)
HQ30d53101301 HQ30d mainframe, PHC10103 standard pH electrode (1 m cable),LDO10101 standard dissolved oxygen electrode (1 m cable)
HQ30d53103303 HQ30d host, PHC10103 standard pH electrode (3 m cable),LDO10103 standard conductivity electrode (3 m cable)
HQ30d53201301 HQ30d host, CDC40101 standard conductivity electrode (1 m cable),LDO10101 standard dissolved oxygen electrode (1 m cable)
HQ30d53203303 HQ30d host, CDC40103 standard conductivity electrode (3 m cable),LDO10103 standard conductivity electrode (3 m cable)
8506300 HQ30d basic dissolved oxygen kit, including HQ30d main unit, LDO10101 dissolved oxygen sensor, pedestal
5825800 carrying case: can hold 2 shock-resistant sensors, one HQ30d or HQ40d main, 5 120 beakers
5189900 low ion concentration flow cell
8506600 hash intelliCAL probe holder (except LBOD electrode)
pH electrode
Ultra Liquid-Filled Standard Composite Electrode: pHC28101(1 m cable), pHC28103(3 m cable)
Gel standard composite electrode: pHC10101(1 m cable), pHC10103(3 m cable)
Gel rugged composite electrodes: pHC10105(5 m cable), pHC10110(10 m cable), pHC10115(15 m), pHC10130(30 m)
Liquid-filled standard composite electrode: pHC30101(1 m cable), pHC30103(3 m cable)
ORP electrode
Gel standard composite electrode: MTC10101(1 m), MTC10103(3 m)
Gel rugged composite electrodes: MTC10105(5 m), MTC10110(10 m), MTC10115(15 m), MTC10130(30 m)
Liquid-filled standard composite electrode: MTC30101(1 m cable), MTC30103(3 m cable)
conductivity electrode
Standard electrode: CDC40101(1 m cable), CDC40103(3 m cable)
Routine electrodes: CDC40105(5 m), CDC40110(10 m), CDC40115(15 m), CDC40130(30 m)
dissolved oxygen electrode
Standard electrode: LDO10101(1 m cable), LDO10103(3 m cable)
rugged electrodes: LDO10105(5 m cable), LDO10110(10 m cable), LDO10115(15 m), LDO10130(30 m)
ISE ion-selective electrode
Sodium ion selective electrode: ISENa38101(1 m cable), ISENa38103(3 m cable)
Ammonia nitrogen electrode: ISENH318101(1 m), ISENH318103(3 m), ISENH418101(1 m), ISENH418103(3 m)
Chloride electrode: ISECl18101(1 m cable), ISECl18103(3 m cable)
Fluoride ion electrode: ISEF12101(1 m cable), ISEF12103(3 m cable)
Nitrate electrode: ISENO318101(1 m cable), ISENO318103(3 m cable)
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Multi-parameter Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Multi-parameter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Multi-parameter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Multi-parameter Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Multi-parameter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Multi-parameter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Multi-parameter Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Multi-parameter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Multi-parameter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Multi-parameter Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Multi-parameter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Multi-parameter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Related Products
Endress+HauserLiquiline CM442
Endress+HauserLiquiline M CM42
Endress+HauserLiquiline CM14
Endress+HauserLiquiline Compact CM82
Endress+HauserLiquiline CM44P
Endress+HauserLiquiline CM442R
Endress+Hauser多参数变送器
Endress+Hauser