Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

TX1315 便携式水质生物毒性检测仪

TX1315 便携式水质生物毒性检测仪

便携式水质生物毒性检测仪

HACH TX1315
TX1315 便携式水质生物毒性检测仪作为针对环境污染、紧急事故、安检及常规检测等目的而设计的便携式水质生物毒性检测仪,新一代Hach TX1315 生物毒性检测仪既支持世界上流行的发光细菌法生物毒性分析,也支持适用于恶劣环境的化学发光法毒性分析,用于现场水中重金属、毒剂、神经毒剂、农药制剂等物质总体毒性检测。不仅如此,Hach TX1315便携式水质生物毒性检测仪集成的ATP(三磷酸腺苷)微生物活性快速检测技术,几分钟就可以获得水体中或物体表面的微生物浓度的关键数据,带来微生物检测技术的新突破。

应用行业:

TX1315便携式水质生物毒性检测仪可用于地表水/水源水、饮用水、污水、石油石化、工业用水、食品饮料、环境应急等行业或场景。

仪器特点:

TX1315水质生物毒性检测仪集多种检测方法于一身。除了常见的发光细菌法,TX1315水质生物毒性检测仪还支持化学发光法,无需提前复苏制备菌种。短短几分钟就可以得到测量结果,非常适合环境应急检测。

TX1315水质生物毒性检测仪的便携性设计,附带应急便携包,适合户外使用。

TX1315水质生物毒性检测仪采用突破性的ATP检测技术,现场定量计算ATP浓度,大大增强水质毒性检测仪的抗干扰能力。

技术指标
测量模式                                   发光细菌法、化学发光法、ATP快速检测
检测器                                      光电倍增管(PMT)
菌种                                         符合 ISO11348和GB/T 15441-1995标准规定的菌种,包括费氏弧菌、明亮发光杆菌
方法标准                                 GB/T 15441-1995 & ISO 11348
操作环境                                 存储温度 -10~50℃, 工作温度 +5~45℃
相对湿度                                 30-95%(25°C)
数据存储                                 1000个
通讯                                       USB接口
相对发光强度(RLU)            0至10,000,000 RLU
线性范围(ATP)                   4 x 10-12 to 1 x 10-6 M ATP      
电池                                      2600 mAh锂电池,可进行1000次以上测量
连续工作时间                        8个小时以上
尺寸                                     77 x 125 x 88 mm(照度计模块) 130 x 70 x 26mm(通讯模块)
重量                                     460g(照度计模块) 152g (通讯模块)
认证                                     CE认证

配件信息
货号                                                              描述
PMT                                                           照度计
EQP-PBM-TF                                             通讯模块
HC-EQP-CASE-PBM                                  野外便携箱
EQP-SP100                                               移液器,100μL
EQP-SP300                                               移液器,300μL
EQP-SP1000                                             移液器,1000μL
EQP-T4                                                     试管架
DIS-CT1255-50                                         试管,12x55mm, PP, 50/pk
LMK-5C                                                     照度计维护包

订购指南
货号                                                                 描述
主机套装
HC-EQP-PBM-PAC                   TX1315生物毒性分析仪套装,包含照度计,通讯模块,野外便携箱,微量移液器(100μL、300μL和1000μL)和试管架(请额外订购试管)
HC-EQP-PBM-PMT                  TX1315生物毒性分析仪主机,包含照度计,通讯模块,野外便携箱(请额外订购试管)
备件
PMT                                                          照度计
EQP-PBM-TF                                            通讯模块
HC-EQP-CASE-PBM                                 野外便携箱
EQP-SP100                                              移液器,100μL
EQP-SP300                                              移液器,300μL
EQP-SP1000                                            移液器,1000μL
EQP-T4                                                    试管架
LMK-5C                                                   照度计维护包
化学发光法测试套件
2887500                                                  化学发光法测试套件(50次测试)
LZP1480                                                  试剂管,塑料,500个
发光细菌法测试套件
LCK491                                                    发光细菌试剂,冻干粉
LCW490                                                   发光细菌测试套件,包含包装箱、复苏液、2% NaCl溶液等
LZP1480                                                  试剂管,塑料,500个
1436369                                                  脱氯试剂,100包
ATP测试套件
QGA-100C                                              第二代ATP测试套装,通用,100次
QGOM-100C                                          第二代ATP测试套装,有机混合物,100次


来源:哈希水质网站公开信息

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Hach-Lab Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Hach-Lab.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Hach-Lab for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Hach-Lab Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Hach-Lab.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Hach-Lab for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Hach-Lab Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Hach-Lab.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Hach-Lab for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Hach-Lab Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Hach-Lab.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Hach-Lab for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.