Nr
Número de pedido
Especificación
31
71323007
Módulo de alimentación
Usage:
Promag/Promass 300/500,
Prosonic Flow/t-mass 300,
transmitter housing,
electronic compartment.
31
71323008
Módulo de alimentación
Usage:
Promag/Promass 300/500,
Prosonic Flow/t-mass 300,
transmitter housing,
electronic compartment.
31
71323009
Módulo de alimentación
Usage:
Promag/Promass/Prosonic Flow/
t-mass/Teqwave MW 300/500 digital,
Non-haz, Zone 2,
transmitter housing,
electronic compartment.
47
71323013
Módulo de placa de conexión electrónica principal, no Ex, 500 digital
Usage:
Promag/Promass/Prosonic Flow/
t-mass/Teqwave MW 500 digital,
transmitter housing,
electronic compartment.
47
71323014
Módulo de placa de conexión electrónica principal, Ex, Promag 500 digital
Usage:
Promag/Prosonic Flow 500 digital,
transmitter housing,
electronic compartment.
36
71323015
Módulo de placa de conexión ISEM, Ex, 500 digital
Usage:
Promag/Promass/t-mass/
Teqwave MW 500 digital,
sensor connection housing.
33
XPD0027-
Módulo electrónico ISEM 300/500
Usage:
Promag 300/500
BA
A
B
00
AA
BB
BD
BJ
BL
BN
BS
C2
C4
C6
CD
CN
CS
CZ
GB
GD
GJ
GL
GN
GR
GS
JD
JJ
KD
MB
MD
MJ
ML
MN
MS
NB
ND
NJ
NL
NN
NS
UB
UD
UJ
UL
UN
UR
US
00
39
71185788
Módulo T-DAT
34
XPD0037-
Módulo de E/S
Usage:
Proline 300/500
AA
A1
B1
C1
D1
E1
F1
G1
H1
K1
00
01
37
71323010
Cartucho de módulo, 300/500, Ex
Usage:
transmitter housing,
electronic compartment.
Consists of:
module cartridge incl.
interconnection board.
46
71323005
Módulo de cable plano
Usage:
Promag/Promass 300/500,
t-mass/Teqwave MW 300,
transmitter housing.
46
71323006
Módulo de cable plano
Usage:
Promag/Promass/t-mass/
Teqwave MW 500 digital,
sensor connection housing.
35
XPD0038-
Módulo de E/S
Usage:
Proline 300/500
AA
1A
1B
1C
1D
00
45
71323075
Módulo de bornera
Usage:
transmitter housing Alu/cast,
connection compartment.
Option A =
HART, PROFIBUS PA, FOUNDATION Fieldbus.
Consists of:
2x connection terminal 2-Pol.,
1x connection terminal 4-Pol.
50
XPD0031-
Módulo de visualización
Usage:
Proline 300/500, DKX001.
BA
A
B
F
G
00
45
71323076
Módulo de bornera
Usage:
transmitter housing Alu/cast,
connection compartment.
Option B =
EtherNet, PROFINET.
Consists of:
2x connection terminal 2-Pol.
45
71327819
Módulo de bornera
Usage:
transmitter housing Alu/cast,
connection compartment.
Option C =
PROFIBUS DP, Modbus RS485.
Consists of:
2x connection terminal 2-Pol.,
1x connection terminal 4-Pol.
45
71323077
Módulo de bornera
Usage:
transmitter housing Alu/polycarbonate,
connection compartment.
Option A =
HART, PROFIBUS PA, FOUNDATION Fieldbus.
Consists of:
1x connection terminal 2-Pol.,
1x connection terminal 3-Pol.,
1x connection terminal 4-Pol.,
1x connection terminal 6-Pol.
45
71323078
Módulo de bornera
Usage:
transmitter housing Alu/polycarbonate,
connection compartment.
Option B =
EtherNet, PROFINET.
Consists of:
1x connection terminal 3-Pol.,
1x connection terminal 4-Pol.,
1x connection terminal 6-Pol.
45
71327820
Módulo de bornera
Usage:
transmitter housing Alu/polycarbonate,
connection compartment.
Option C =
PROFIBUS DP, Modbus RS485.
Consists of:
1x connection terminal 2-Pol.,
1x connection terminal 3-Pol.,
1x connection terminal 4-Pol.,
1x connection terminal 6-Pol.
44
71615501
Placa de conexión
Usage:
Promag P 10 Ex, D/W 10 non-haz,
Promag P/W 500 Ex,
Sensor connection housing.
Consists of:
connection board,
cover to connection board.
44
71615501
Placa de conexión
Usage:
Promag P 10 Ex, D/W 10 non-haz,
Promag P/W 500 Ex,
Sensor connection housing.
Consists of:
connection board,
cover to connection board.
44
71615501
Placa de conexión
Usage:
Promag P 10 Ex, D/W 10 non-haz,
Promag P/W 500 Ex,
Sensor connection housing.
Consists of:
connection board,
cover to connection board.
44
71615501
Placa de conexión
Usage:
Promag P 10 Ex, D/W 10 non-haz,
Promag P/W 500 Ex,
Sensor connection housing.
Consists of:
connection board,
cover to connection board.
44
71615502
Kit connec. board,floating,Promag 10/500
Usage:
Promag P 10 Ex, W 10 non-haz,
Promag P/W 500 Ex,
Sensor connection housing.
Consists of:
connection board,
cover to connection board.
20
71323016
Módulo de tapa
Usage:
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 300, Prosonic Flow 500,
transmitter housing Alu, Non-haz.
Promag/Promass 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing Alu, Ex.
Consists of:
cover sight glass, Alu,
O-Ring 110.7x3.53 HNBR.
20
71323017
Módulo de tapa
Usage:
Promass/Prosonic Flow/t-mass 300,
transmitter housing Alu, Non-haz.
Promass 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing Alu, Ex.
Consists of:
cover sight glass, Alu,
O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
20
71323020
Módulo de tapa de aluminio con ventana de vidrio
Usage:
Promag/Promass/Prosonic Flow/t-mass 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing Alu, Ex.
Consists of:
cover sight glass, Alu,
O-Ring 110.7x3.53 HNBR.
20
71323021
Módulo de tapa
Usage:
Promass/Prosonic Flow/t-mass 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing Alu, Ex.
Consists of:
cover sight glass, Alu,
O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
20
71323024
Módulo de tapa
Usage:
Promass/Prosonic Flow 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing cast, Ex.
Consists of:
cover sight glass, cast,
O-Ring 110.7x3.53 HNBR.
20
71323025
Módulo de tapa
Usage:
Promass/Prosonic Flow 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing cast, Ex.
Consists of:
cover sight glass cast,
O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
70
71323026
Módulo de tapa
Usage:
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing Alu/cast.
Consists of:
10x O-Ring 110.7x3.53 HNBR.
70
71323027
Módulo de tapa
Usage:
Promass/Prosonic Flow/t-mass 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing Alu/cast,
Consists of:
O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
22
71323032
Módulo de tapa
Usage:
Promag/Promass/Prosonic Flow/t-mass 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing Alu, Ex.
Consists of:
cover Alu,
O-Ring 120,2x3,53 HNBR.
22
71323033
Módulo de tapa
Usage:
Promass/Prosonic Flow/t-mass 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing Alu, Ex.
Consists of:
cover Alu,
O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.
22
71323034
Módulo de tapa
Usage:
Promass/Prosonic Flow 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing cast, Ex.
Consists of:
cover cast,
O-Ring 120,2x3,53 HNBR.
22
71323035
Módulo de tapa
Usage:
Promass/Prosonic Flow 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing cast, Ex.
Consists of:
cover cast,
O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.
74
71323036
Módulo de tapa
Usage:
Promag/Promass/Prosonic Flow/t-mass 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing Alu/cast, Ex.
Consists of:
10x O-Ring 120,2x3,53 HNBR.
74
71323037
Módulo de tapa
Usage:
Promass/Prosonic Flow/t-mass 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing Alu/cast, Ex.
Consists of:
O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.
23
71323038
Módulo de tapa del instrumento
Usage:
Promag 10,
Promag/Promass/Prosonic Flow 500,
wall mount transmitter Alu,
connection compartment.
Consists of:
cover Alu,
O-Ring 88,50x3,53 HNBR.
23
71323039
Módulo de tapa
Usage:
Promag/Promass/Prosonic Flow 500,
wall mount transmitter Alu, Ex,
connection compartment.
Consists of:
cover Alu,
O-Ring 88,50x3,53 FVMQ, -50oC/-58oF.
23
71323040
Módulo de tapa
Usage:
Promag/Promass/Prosonic Flow 500,
wall mount transmitter cast, Ex,
connection compartment.
Consists of:
cover cast,
O-Ring 88,50x3,53 HNBR.
23
71323041
Módulo de tapa
Usage:
Promag/Promass/Prosonic Flow 500,
wall mount transmitter cast, Ex,
connection compartment.
Consists of:
cover cast,
O-Ring 88,50x3,53 FVMQ, -50oC/-58oF.
75
71323042
Junta de tapa del instrumento
Usage:
Promag 10,
Promag/Promass/Prosonic Flow 500,
wall mount transmitter Alu/cast,
connection compartment.
Consists of:
10x O-Ring 88,50x3,53 HNBR.
75
71323043
Módulo de tapa
Usage:
Promag/Promass/Prosonic Flow 500,
wall mount transmitter Alu/cast, Ex,
connection compartment.
Consists of:
O-Ring 88,50x3,53 FVMQ, -50oC/-58oF.
20
71384170
Tapa del instrumento Promag400/500
Usage:
Prosonic Flow 400, Promag 400(C),
(C) = generation index C,
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital,
transmitter housing Alu.
Consists of:
cover Alu complete included
O-Ring 196,40x3,53 HNBR,
default and -50oC/-58oF,
wire with screw lock 1,5x150.
20
71408508
Tapa del instrumento
Usage:
Prosonic Flow 400,
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital, Promag 800(C),
(C) = generation index C,
transmitter housing polycarbonate.
Consists of:
cover polycarbonate complete,
O-Ring 196,44x3,53 VMQ,
default and -50oC/-58oF,
wire with screw lock 1,5x150.
70
71278078
Junta de tapa del instrumento
Usage:
Prosonic Flow 400, Promag 400(C),
(C) = generation index C,
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital,
transmitter housing Alu.
Consists of:
10x O-Ring 196,40x3,53 HNBR,
default and -50oC/-58oF.
70
71278077
Junta de policarbonato para tapa del instrumento
Usage:
Prosonic Flow 400,
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital,
Promag 400/800(C),
(C) = generation index C,
transmitter housing polycarbonate.
Consists of:
10x O-Ring 196,44x3,53 VMQ.
24
71228796
Módulo de tapa del instrumento
Usage:
Promag 10/500,
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital,
Promag 400/800(C),
(C) = generation index C,
sensor connection housing.
Consists of:
cover Alu,
O-Ring 113,90x3,53 HNBR.
24
71228796
Módulo de tapa del instrumento
Usage:
Promag 10/500,
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital,
Promag 400/800(C),
(C) = generation index C,
sensor connection housing.
Consists of:
cover Alu,
O-Ring 113,90x3,53 HNBR.
24
71228796
Módulo de tapa del instrumento
Usage:
Promag 10/500,
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital,
Promag 400/800(C),
(C) = generation index C,
sensor connection housing.
Consists of:
cover Alu,
O-Ring 113,90x3,53 HNBR.
24
71228796
Módulo de tapa del instrumento
Usage:
Promag 10/500,
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital,
Promag 400/800(C),
(C) = generation index C,
sensor connection housing.
Consists of:
cover Alu,
O-Ring 113,90x3,53 HNBR.
24
71228796
Módulo de tapa del instrumento
Usage:
Promag 10/500,
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital,
Promag 400/800(C),
(C) = generation index C,
sensor connection housing.
Consists of:
cover Alu,
O-Ring 113,90x3,53 HNBR.
73
71228798
Módulo de junta de carcasa
Usage:
Promag 10/500,
Promag 500 digital,
Promag 400/800(C),
(C) = generation index C,
sensor connection housing.
Consists of:
O-Ring 113,90x3,53 HNBR for cover,
gasket EPDM for
housing/sensor L/P/W,
O-Ring 29,87x1,78 HNBR for sensor plug.
73
71228798
Módulo de junta de carcasa
Usage:
Promag 10/500,
Promag 500 digital,
Promag 400/800(C),
(C) = generation index C,
sensor connection housing.
Consists of:
O-Ring 113,90x3,53 HNBR for cover,
gasket EPDM for
housing/sensor L/P/W,
O-Ring 29,87x1,78 HNBR for sensor plug.
73
71228798
Módulo de junta de carcasa
Usage:
Promag 10/500,
Promag 500 digital,
Promag 400/800(C),
(C) = generation index C,
sensor connection housing.
Consists of:
O-Ring 113,90x3,53 HNBR for cover,
gasket EPDM for
housing/sensor L/P/W,
O-Ring 29,87x1,78 HNBR for sensor plug.
73
71228798
Módulo de junta de carcasa
Usage:
Promag 10/500,
Promag 500 digital,
Promag 400/800(C),
(C) = generation index C,
sensor connection housing.
Consists of:
O-Ring 113,90x3,53 HNBR for cover,
gasket EPDM for
housing/sensor L/P/W,
O-Ring 29,87x1,78 HNBR for sensor plug.
73
71228798
Módulo de junta de carcasa
Usage:
Promag 10/500,
Promag 500 digital,
Promag 400/800(C),
(C) = generation index C,
sensor connection housing.
Consists of:
O-Ring 113,90x3,53 HNBR for cover,
gasket EPDM for
housing/sensor L/P/W,
O-Ring 29,87x1,78 HNBR for sensor plug.
24
71323063
Módulo de tapa
Usage:
Promag/Promass 500,
Promag/Promass/Prosonic Flow/t-mass
500 digital, sensor connection housing.
Consists of:
cover cast,
O-Ring 120,2x3,53 HNBR.
73
71323067
Módulo de junta de carcasa
Usage:
Promag 500,
Promag 500 digital,
sensor connection housing.
Consists of:
O-Ring 120,2x3,53 HNBR for cover,
O-Ring 88,50x3,53HNBR for housing/sensor
O-Ring 29,87x1,78 HNBR for sensor plug.
71
71323069
Módulo de junta de interfaz
Usage:
transmitter housing/sensor or
transmitter housing/wall mount.
Consists of:
5x O-Ring 88,50x3,53 HNBR for
interface,
5x O-Ring 29,87x1,78 HNBR for
for sensor plug.
71
71323070
Módulo de junta de interfaz
Usage:
transmitter housing/wall mount.
Consists of:
O-Ring 88,50x3,53 FVMQ for
interface, -50oC/-58oF,
O-Ring 29,87x1,78 FVMQ for
for sensor plug, -50oC/-58oF.
11
71323081
Módulo de tapa protectora
Usage:
transmitter housing Alu/cast,
connection compartment.
Option A =
HART, PROFIBUS PA, PROFIBUS DP,
Modbus RS485, FOUNDATION Fieldbus.
Consists of:
Connection compartment protective cover,
display carrier, 2x screw M4x10.
11
71323082
Módulo de tapa protectora
Usage:
transmitter housing Alu/cast,
connection compartment.
Option B =
EtherNet, PROFINET.
Consists of:
Connection compartment protective cover,
display carrier, 2x screw M4x10.
13
71276494
Abrazadera de fijación, tornillo
Usage: Promass 100, Promag 100,
Prosonic Flow E 100/E Heat,
CNGmass, LPGmass, LNGmass,
Promag/Promass 500, Promag 10,
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital,
Promag 400/800(C),
(C) = generation index C,
sensor connection housing.
Consists of:
cover clamp, screw M4x16.
13
71276494
Abrazadera de fijación, tornillo
Usage: Promass 100, Promag 100,
Prosonic Flow E 100/E Heat,
CNGmass, LPGmass, LNGmass,
Promag/Promass 500, Promag 10,
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital,
Promag 400/800(C),
(C) = generation index C,
sensor connection housing.
Consists of:
cover clamp, screw M4x16.
13
71276494
Abrazadera de fijación, tornillo
Usage: Promass 100, Promag 100,
Prosonic Flow E 100/E Heat,
CNGmass, LPGmass, LNGmass,
Promag/Promass 500, Promag 10,
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital,
Promag 400/800(C),
(C) = generation index C,
sensor connection housing.
Consists of:
cover clamp, screw M4x16.
13
71276494
Abrazadera de fijación, tornillo
Usage: Promass 100, Promag 100,
Prosonic Flow E 100/E Heat,
CNGmass, LPGmass, LNGmass,
Promag/Promass 500, Promag 10,
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital,
Promag 400/800(C),
(C) = generation index C,
sensor connection housing.
Consists of:
cover clamp, screw M4x16.
13
71276494
Abrazadera de fijación, tornillo
Usage: Promass 100, Promag 100,
Prosonic Flow E 100/E Heat,
CNGmass, LPGmass, LNGmass,
Promag/Promass 500, Promag 10,
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital,
Promag 400/800(C),
(C) = generation index C,
sensor connection housing.
Consists of:
cover clamp, screw M4x16.
71450719
Adaptador M12, RJ45, L= 80mm (para t-mass F 300/50
Usage:
Proline 300/500.
71450719
Adaptador M12, RJ45, L= 80mm (para t-mass F 300/50
Usage:
Proline 300/500.
71450719
Adaptador M12, RJ45, L= 80mm (para t-mass F 300/50
Usage:
Proline 300/500.
71450719
Adaptador M12, RJ45, L= 80mm (para t-mass F 300/50
Usage:
Proline 300/500.
71450719
Adaptador M12, RJ45, L= 80mm (para t-mass F 300/50
Usage:
Proline 300/500.
71450719
Adaptador M12, RJ45, L= 80mm (para t-mass F 300/50
Usage:
Proline 300/500.
71450719
Adaptador M12, RJ45, L= 80mm (para t-mass F 300/50
Usage:
Proline 300/500.
71450719
Adaptador M12, RJ45, L= 80mm (para t-mass F 300/50
Usage:
Proline 300/500.
82
71228792
Tapa protectora de visualización
Usage:
Prosonic Flow 400, Promag 400(C),
(C) = generation index C,
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital,
transmitter housing Alu.
Consists of:
display protection 1.4301,
installation material.
87
71343504
Módulo de carcasa de protección
Usage:
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 400/800/500 digital,
transmitter housing.
Consists of:
weather protection cover 4404.
87
71343505
Módulo de carcasa de protección
Usage:
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing.
Consists of:
weather protection cover 4404,
installation material.
71346427
Módulo de montaje en tubería
For Product:
Promag 500 digital
Promass 500 digital
t-mass 500 digital
Prosonic Flow 500 digital
Teqwave MW 500 digital
Prosonic Flow 400
71346428
Módulo de montaje en tubería
71351317
Receptor inalámbrico para distancia extendida
Consists of:
Connection cable in the transmitter,
Ex cable entry for antenna,
1.5m cable,
antenna,
angle with union nut.
5X5BXX-
Transmisor 500, 5X5BXX
With an integrated web server.
AA
BB
BD
BJ
BL
BN
BS
C2
C4
C6
CD
CN
CS
CZ
GB
GD
GJ
GL
GN
GR
GS
JD
JJ
KD
MB
MD
MJ
ML
MN
MS
NB
ND
NJ
NL
NN
NS
UB
UD
UJ
UL
UN
UR
US
9
D
E
I
99
BA
CA
CC
GA
HA
LA
MA
NA
RA
RB
RC
SA
TA
9
A
B
C
D
E
F
G
H
I
J
9
A
B
C
D
E
F
G
H
I
J
9
A
B
C
D
E
G
H
I
J
9
F
G
9
A
B
9
A
D
L
1
2
3
4
5
9
A
B
E
F
J
L
3
4
5
6
9
A
B
C
D
L
M
N
P
R
S
T
U
V
AA
A1
A2
AA
AB
AC
AD
AE
AF
AG
AH
AI
AJ
AK
AL
AM
AQ
AR
AT
C9
CV
E9
EA
EB
EC
EL
I7
I9
JN
K9
L9
LA
N9
NB
P8
P9
PA
PB
PC
58
60
61
63
64
65
66
67
68
70
71
72
73
74
75
76
Z1
Z2
DK5012-
Cable de sensor 500
Connection Cable (analog
and digital) between Sensor Junction
Housing and Transmitter for Remote
Devices of Proline 500.
AA
AA
BB
BD
BJ
BL
BN
BS
C2
C4
C6
CD
CN
CS
CZ
GB
GD
GJ
GL
GN
GR
GS
JD
JJ
KD
MB
MD
MJ
ML
MN
MS
NB
ND
NJ
NL
NN
NS
UB
UD
UJ
UL
UN
UR
US
A
B
9
A
L
1
2
3
4
5
9
B
E
F
J
L
JN
K9
DK5GD-
Anillo de puesta a tierra DK5GD
Includes 1 grounding disc/protection
disc
15A
15B
15D
15E
1FA
1FB
1FD
1FE
1HA
1HB
1HD
1HE
1ZA
1ZB
1ZD
1ZE
25A
25B
25D
25E
2FA
2FB
2FD
2FE
2HA
2HB
2HD
2HE
32A
32B
32D
32E
3FA
3FB
3HA
3HB
3HD
3HE
40A
40B
40D
40E
4FA
4FB
4HA
4HB
50A
50B
50D
50E
5HA
5HB
65A
65B
65D
65E
6HA
6HB
80A
80B
80D
80E
9
A
E
9
A
B
C
D
L
M
T
U
DK5GC-
Cable de puesta a tierra DK5GC
A kit includes 2 cables
15
1F
1H
1Z
25
2F
2H
32
3F
3H
40
50
65
80
0
A
B
C
D
L
M
T
U
XPRFID-
Etiqueta RFID de repuesto
Consists of:
RFID TAG, fixing wire, crimp sleeve.
AA
BA
CA
IA
KA
MA
NA
UA
UR
1