CPS13 Chinese Manual Download

You can directly download the CPS13 Chinese manual to obtain complete installation, operation, and maintenance guidelines.

Download CPS13 Chinese Manual.pdf Download CPS13 Chinese Manual.pdf

CPS13 Product Overview

CPS13 is a high-precision industrial pressure switch widely used in hydraulic, pneumatic, and water treatment systems. Its core function is to monitor pressure and output switching signals to achieve automatic control and safety protection.

The product features a compact design, high repeat accuracy, and wide pressure range, making it suitable for harsh industrial environments.

Main Application Areas

  • Hydraulic system pressure monitoring
  • Pneumatic equipment pressure control
  • Water treatment and pump station protection
  • Industrial automation production lines

Technical Parameters and Selection

When selecting a model, it is necessary to match the model according to the system pressure range, connection size, and electrical requirements. The table below lists typical parameters of the CPS13.

ParameterSpecification
Pressure range0.5~10 MPa (optional)
Accuracy±1% FS
Connection materialStainless steel 304
Electrical connectionM12 connector
Protection ratingIP65

Selection Steps

  1. Determine the maximum working pressure of the system and select the corresponding range.
  2. Confirm the connection thread specification (e.g., G1/4, NPT1/4).
  3. Select the electrical output type (normally open/normally closed) according to the control voltage.
  4. Check whether the protection rating meets the on-site environment.

Installation and Commissioning Points

Correct installation is the prerequisite for ensuring the long-term stable operation of the CPS13. Please follow the steps below.

Installation Steps

  1. Turn off system pressure and drain the pipeline.
  2. Screw the switch into the connection and tighten it with a wrench, avoiding over-tightening.
  3. Connect the electrical cable and ensure the sealing ring is intact.
  4. Slowly open the pressure and observe whether the set point operates normally.

Commissioning Precautions

  • Use the adjustment screw to set the switch point; turn clockwise to increase and counterclockwise to decrease.
  • Avoid operating above the maximum pressure to prevent damage to the sensor.
  • Regularly check sealing performance to prevent leakage.

Maintenance and Troubleshooting

Regular maintenance can extend the service life of the CPS13. Common faults include no output, set point drift, etc.

  • No output: Check electrical connections and power supply.
  • Set point drift: Recalibrate or replace sealing components.
  • Leakage: Tighten the connection or replace the sealing ring.

For detailed fault codes and handling methods, please refer to the CPS13 Chinese manual.