6TAB Insertion Type Mass Flow Meter Overview
6TAB insertion type mass flow meter is designed specifically for liquid mass flow measurement. It adopts an insertion structure and can be installed directly in pipelines, making it suitable for homogeneous liquids such as water, oil products, and chemical solutions. Its core advantage lies in direct mass flow measurement, requiring no additional temperature and pressure compensation, simplifying the system and improving accuracy.
This manual is intended to help engineering technicians and procurement personnel quickly understand product performance, installation specifications, and maintenance methods. A Chinese manual PDF download is provided at the end, including complete parameters and wiring diagrams.
Working Principle and Core Advantages
Measurement Principle
Based on the Coriolis force or thermal principle (depending on the specific model), the 6TAB directly outputs a mass flow signal by detecting the phase difference or thermal diffusion change caused by the fluid mass flow. The insertion design reduces pressure loss and is suitable for large-diameter pipelines.
Main Advantages
- High accuracy: typical accuracy ±0.5% of reading, meeting trade settlement and process control requirements.
- Wide turndown ratio: up to 100:1, adapting to working conditions with large flow fluctuations.
- Low maintenance: no moving parts, reducing wear and blockage risks.
- Flexible installation: the insertion structure supports installation under pressure, reducing downtime costs.
Technical Parameters Quick Reference
The table below lists the key parameters of the 6TAB insertion type mass flow meter (liquid type) for model selection reference.
| Parameter | Typical Value | Remarks |
|---|---|---|
| Measured medium | Liquid (homogeneous, without large amounts of bubbles) | Viscosity range must be confirmed |
| Nominal diameter range | DN50~DN2000 | Insertion type is suitable for large diameters |
| Accuracy | ±0.5% of reading | Repeatability ±0.2% |
| Working pressure | ≤4.0 MPa | Higher pressure customizable |
| Medium temperature | -40~200℃ | High-temperature type optional |
| Output signal | 4-20mA, pulse, RS485 | Supports HART protocol |
| Power supply | 24VDC | Power consumption ≤5W |
| Protection class | IP67 | IP68 optional |
Installation Steps and Precautions
Preparation Before Installation
- Confirm that the pipeline is filled with liquid and free of bubbles; install a gas eliminator if necessary.
- Check that the flow meter nameplate parameters match the working conditions, especially pressure and temperature.
- Prepare appropriate tools and seals, and ensure the pipeline can be drilled or has a reserved mounting seat.
Installation Steps
- Drill a hole at a suitable position in the pipeline (upstream straight pipe section ≥10D, downstream ≥5D) and weld the mounting seat.
- Insert the insertion sensor into the pipeline, ensuring the measuring head is near the centerline of the pipeline.
- Adjust the insertion depth, tighten the positioning nut, and ensure sealing without leakage.
- Connect the cable, connect the power and signal lines according to the wiring diagram, and pay attention to grounding the shielding layer.
- After power-on, check the zero point and perform zero calibration under full-pipe static conditions.
Precautions
- Avoid installation at the pump outlet or downstream of valves to prevent vortices and pulsation from affecting accuracy.
- The liquid should flow in one direction; reverse flow may damage the sensor or cause measurement errors.
- For media prone to scaling, clean the measuring head regularly; maintenance every 3~6 months is recommended.
Maintenance and Troubleshooting
Daily Maintenance
Regularly check sealing performance and zero drift, and record output signals and process parameters. If abnormalities are found, first eliminate external factors such as empty pipe, bubbles, or medium changes.
Common Faults
| Phenomenon | Possible Cause | Countermeasure |
|---|---|---|
| Output too low | Scaling on measuring head, bubbles | Clean, vent |
| No output | Power failure, wiring error | Check power supply and wiring |
| Large fluctuation | Pulsating flow, improper installation position | Add damping, adjust position |