10L Electromagnetic Flowmeter Spare Parts List Overview

This article summarizes the common spare parts for the Promag 10L electromagnetic flowmeter and provides selection codes for transmitter, mounting components, cables, grounding rings, etc. It is suitable for engineering technicians and procurement personnel to quickly consult and select.

10L Electromagnetic Flowmeter Spare Parts List

Spare Parts List

The following spare parts are listed by order number, including specifications. Note: HE means harsh environment version.

Nr Order Number Specification
A50104751PCB mainboard
A50104752PMAG10 mainboard
A71098237PCB mainboard (HE)
A71098239PCB mainboard (HE)
350104749Fuse
350104750Fuse
B5010474510/91W display module with keypad
C50104754Terminal block
C71098240Terminal module (HE)
D50098018Sensor part terminal block (for 10/50/51/53/55/400/800)
D71039497Sensor part terminal block (for 10/50/53/55, HE)
15010813810/91W terminal block (Kit Terminal Block 10/91W)
1350094038Terminal compartment cover (10/5X/40/8X/93/65/92F)
1371247838Service cover, remote version (for 10/5X/8X/8DF/8CN/92F/65/400/800), includes: Cover Rep.kit for G14, O-Ring 110.00 x 4.50 HNBR, Grease
950094038Terminal compartment cover (10/5X/40/8X/93/65/92F)
550104746Cover with glass window
650104747Blind cover
1050103658Cable gland
1050096840Kit 10 cable glands M20x1,5
1050098041Kit 10 extension M20x1.5/G 1/2"
1050098042Kit 10 extension M20x1.5/NPT 1/2"
450104748Display module carrier board 10/91W
750104753Cover seal
850097147Ground terminal/cover locking clip (10/1YH/23/65/72/73/91W/92F/8FF/8FE/8CM)
250099102Cast aluminum/stainless steel housing sleeve
1550098019Mounting screws and mounting accessories (for 10/50/51/53/55/400/800, sensor: D/E/H/L/P/S/W)
1250098020Mounting screws and mounting accessories (for 10/23/50/51/53/55, sensor: D/E/H/L/P/S/W)
1450098023Washer (for 10/50/51/53/55/400/800, sensor: D/E/L/P/S/W)
1150098024Washer (for 10/23/50/51/53/55, sensor: D/E/L/P/S/W)

Transmitter Selection Code

The Promag 10 transmitter model code is 10XXX-, suitable for electromagnetic flowmeters. The following are the selection options.

Application and Version

  • Application: XXX (Promag 10W, 10P, 10H, 10D, 10L, 10E)
  • Version: XX (transmitter only)

Approval

  • A: Non-hazardous area
  • R: FM NI Cl. I Div. 2 / CSA Cl. I Div. 2

Housing

  • A: Compact aluminum, IP67 NEMA4X
  • G: Remote aluminum, IP67 NEMA4X
  • P: Compact aluminum, IP67 NEMA4X, HE (harsh environment)
  • T: Remote aluminum, IP67 NEMA4X, HE (harsh environment)

Cable (Remote Version)

  • 0: Not used
  • 2: 10m/30ft coil and signal cable
  • 4: ..... m coil and signal cable
  • 5: ..... ft coil and signal cable

Cable Entry

  • A: Gland M20
  • B: Thread NPT 1/2
  • C: Thread G 1/2

Power Supply and Display

  • 0: 85-250VAC; no display, remote configuration
  • 1: 20-28VAC / 11-40VDC; no display, remote configuration
  • 4: 85-250VAC; two-line display, key operation
  • 5: 20-28VAC / 11-40VDC; two-line display, key operation

Adjustment and Software Function

  • A: Factory setting; basic version

Output and Input

  • A: 4-20mA HART + passive pulse

Mounting Components Selection Code

The following are the selection codes for Promag10/50/51/53/55 transmitter mounting components, remote cables, grounding wires, grounding rings.

Transmitter Mounting Components DK5WM-

Suitable for 10/50/51/53/55/800.

  • Application: B (remote, field pipe 3/4 - 3inch)

Remote Cable DK5CA-

Suitable for 10/50/51/53/55/400/800. 1 set includes 1 coil cable and 1 signal cable.

  • Cable, Remote Version: 2 (10m/30ft), 4 (..... m), 5 (..... ft)
  • Approval: A (non-hazardous area + ATEX II 3G, FM/CSA)

Grounding Wire DK5GC-

One set includes 2 cables.

  • Nominal Diameter: 1F (DN150 6"), 1H (DN100 4"), 1Z (DN125), 25 (DN25 1"), 2F (DN250 10"), 2H (DN200 8"), 32 (DN32), 3F (DN350 - DN2000), 3H (DN300 12"), 40 (DN40 1-1/2"), 50 (DN50 2"), 65 (DN65), 80 (DN80 3")
  • Process Connection: 5 (PN16, AS4087), 7 (Table E, AS2129), C (PN16 EN1092-1(DIN2501)), D (PN1016 EN1092-1(DIN2501)), L (Cl.150 ANSI B16.5)

Grounding Ring DK5GD-

Includes 1 grounding disk/protection disk.

  • Nominal Diameter: 1FA (DN150 6", 1.4435/316L), 1FB (DN150 6", Alloy C-22), 1HA (DN100 4", 1.4435/316L), 1HB (DN100 4", Alloy C-22), 1ZA (DN125, 1.4435/316L), 1ZB (DN125, Alloy C-22), 25A (DN25 1", 1.4435/316L), 25B (DN25 1", Alloy C-22), 2FA (DN250 10", 1.4435/316L), 2FB (DN250 10", Alloy C-22), 2HA (DN200 8", 1.4435/316L), 2HB (DN200 8", Alloy C-22), 32A (DN32, 1.4435/316L), 32B (DN32, Alloy C-22), 3FA (DN350 14", 1.4435/316L), 3FB (DN350 14", Alloy C-22), 3HA (DN300 12", 1.4435/316L), 3HB (DN300 12", Alloy C-22), 3SA (DN375 15", 1.4435/316L), 3SB (DN375 15", Alloy C-22), 40A (DN40 1 1/2", 1.4435/316L), 40B (DN40 1 1/2", Alloy C-22), 4FA (DN450 18", 1.4435/316L), 4FB (DN450 18", Alloy C-22), 4HA (DN400 16", 1.4435/316L), 4HB (DN400 16", Alloy C-22), 50A (DN50 2", 1.4435/316L), 50B (DN50 2", Alloy C-22), 5HA (DN500 20", 1.4435/316L), 5HB (DN500 20", Alloy C-22), 65A (DN65, 1.4435/316L), 65B (DN65, Alloy C-22), 6HA (DN600 24", 1,4435/316L), 6HB (DN600 24", Alloy C-22), 7FA (DN750 30", 1.4435/316L), 7HA (DN700 28", 1.4435/316L), 80A (DN80 3", 1.4435/316L), 80B (DN80 3", Alloy C-22), 8HA (DN800 32", 1.4435/316L), RHA (DN900 36", 1.4435/316L), T0A (DN1000 40", 1.4435/316L), T2A (DN1200 48", 1.4435/316L), V0A (AWWA 42", 1.4435/316L)
  • Liner: E (PTFE), H (hard rubber), U (polyurethane)
  • Process Connection: 5 (PN16, AS4087), 7 (Table E, AS2129), 9 (special version, TSP number required), C (PN16 EN1092-1(DIN2501)), D (PN10 EN1092-1(DIN2501)), E (PN6, EN1092-1(DIN2501)), L (Cl.150 ANSI B16.5), P (Cl.D, AWWA C207)

Communication Interface FXA193-

Service interface for connecting the service port of Proline and ToF devices to the RS 232C serial interface (9-pin) of a personal computer.

Delivery Content

  • Service interface with RS 232C connection cable (9-pin)
  • FXA "USB" cable for additional power supply to FXA193 from PC USB port
  • Service software ToF Tool-Fieldtool package

Approval

  • 9: Special version, TSP number required
  • A: For non-hazardous area
  • B: ATEX II (1) GD
  • C: CSA/FM Class I Div. 1
  • D: ATEX, CSA, FM

Connection Cable

  • 9: Special version, TSP number required
  • A: Proline devices
  • B: ToF devices
  • E: Proline and ToF devices
  • F: Ex two-wire devices
  • G: Proline devices and Ex two-wire devices
  • H: Proline, ToF and Ex two-wire devices
  • X: No connection cable

Summary

This article details the spare parts and selection codes for the 10L electromagnetic flowmeter, including transmitter, mounting components, cables, grounding rings, and communication interfaces. Correct selection of spare parts and selection codes ensures reliable operation and maintenance of the flowmeter. For more information, please refer to the relevant technical documents.