Promag 10P Spare Parts List and Selection Guide
This article provides the Promag 10P electromagnetic flowmeter spare parts list and selection code details, covering key spare parts such as the mainboard, fuses, and display module, as well as selection parameters for transmitters, cables, grounding rings, etc., helping engineering technicians and procurement quickly locate the required components.
2022-04-22
admin Views 225
Promag 10P Spare Parts List
The following spare parts are suitable for the Promag 10 series electromagnetic flowmeter. Please select accurately according to the order number and specification description. Spare parts are arranged by position number. Some spare parts have a harsh environment (HE) version, suitable for harsh environments.
| Position |
Order Number |
Specification Description |
Remarks |
| A | 50104751 | PCB mainboard | |
| A | 50104752 | PMAG10 mainboard | |
| A | 71098237 | PCB mainboard | HE = harsh environment |
| A | 71098239 | PCB mainboard | HE = harsh environment |
| 3 | 50104749 | Fuse | |
| 3 | 50104750 | Fuse | |
| B | 50104745 | 10/91W display module with keypad | |
| C | 50104754 | Terminal | |
| C | 71098240 | Terminal module | HE = harsh environment |
| D | 50098018 | Sensor part terminal | For: 10/50/51/53/55/400/800 |
| D | 71039497 | Sensor part terminal | For: 10/50/53/55, HE = harsh environment |
| 1 | 50108138 | 10/91W terminal block | Kit Terminal Block 10/91W |
| 13 | 50094038 | Terminal compartment cover | 10/5X/40/8X/93/65/92F |
| 13 | 71247838 | Service cover, remote version | For: 10/5X/8X/8DF/8CN/92F/65/400/800, includes: Cover Rep.kit for G14, O-Ring 110.00 x 4.50 HNBR, Grease |
| 9 | 50094038 | Terminal compartment cover | 10/5X/40/8X/93/65/92F |
| 5 | 50104746 | Meter cover with glass window | |
| 6 | 50104747 | Blind meter cover | |
| 10 | 50103658 | Cable gland | |
| 10 | 50096840 | 10 pcs M20x1.5 cable glands | Kit 10 cable glands M20x1.5 |
| 10 | 50098041 | M20x1.5/G 1/2" adapter | Kit 10 extension M20x1.5/G 1/2" |
| 10 | 50098042 | M20x1.5/NPT 1/2" adapter | Kit 10 extension M20x1.5/NPT 1/2" |
| 4 | 50104748 | Display module carrier board 10/91W | |
| 7 | 50104753 | Meter cover seal ring | |
| 8 | 50097147 | Ground terminal/cover locking clip | 10/1YH/23/65/72/73/91W/92F/8FF/8FE/8CM |
| 2 | 50099102 | Cast aluminum/stainless steel housing sleeve | |
| 15 | 50098019 | Mounting screws and mounting accessories | For: 10/50/51/53/55/400/800, sensor: D/E/H/L/P/S/W |
| 12 | 50098020 | Mounting screws and mounting accessories | For: 10/23/50/51/53/55, sensor: D/E/H/L/P/S/W |
| 14 | 50098023 | Washer | For: 10/50/51/53/55/400/800, sensor: D/E/L/P/S/W |
| 11 | 50098024 | Washer | For: 10/23/50/51/53/55, sensor: D/E/L/P/S/W |
Promag 10 Transmitter Selection Code
The following selection codes are applicable to the Promag 10 series transmitters, including 10W, 10P, 10H, 10D, 10L, 10E, etc. When selecting, please combine the codes according to application requirements.
Application and Version
- 10XXX-: Promag 10 transmitter 10XXX electromagnetic flowmeter
- XXX: Application (Promag 10W, 10P, 10H, 10D, 10L, 10E)
- XX: Version (transmitter only)
Approval
| Code | Description |
| A | Non-hazardous area |
| R | FM NI Cl. I Div. 2 / CSA Cl. I Div. 2 |
Housing
| Code | Description |
| A | Compact aluminum, IP67 NEMA4X |
| G | Field aluminum, IP67 NEMA4X |
| P | Compact aluminum, IP67 NEMA4X, HE (HE= harsh environment) |
| T | Field aluminum, IP67 NEMA4X, HE (HE= harsh environment) |
Cable (Remote Version)
| Code | Description |
| 0 | Not used |
| 2 | 10m/30ft coil and signal cable |
| 4 | ..... m coil and signal cable |
| 5 | ..... ft coil and signal cable |
Cable Entry
| Code | Description |
| A | Gland M20 |
| B | Thread NPT 1/2 |
| C | Thread G 1/2 |
Power Supply; Display
| Code | Description |
| 0 | 85-250VAC; no display, remote configuration |
| 1 | 20-28VAC / 11-40VDC; no display, remote configuration |
| 4 | 85-250VAC; 2-line display, keypad operation |
| 5 | 20-28VAC / 11-40VDC; 2-line display, keypad operation |
Adjustment; Software Function
| Code | Description |
| A | Factory setting; basic version |
Output, Input
| Code | Description |
| A | 4-20mA HART + pulse passive |
Promag 10/50/51/53/55 Remote Cable DK5CA
Remote cable kit for Promag 10/50/51/53/55/400/800, each kit contains 1 coil cable and 1 signal cable.
| Code | Description |
| 2 | 10m/30ft |
| 4 | ..... m |
| 5 | ..... ft |
Approval:
| Code | Description |
| A | Non-hazardous area + ATEX II 3G, FM/CSA |
Promag 10/50/51/53/55 Transmitter Mounting Kit DK5WM
Transmitter mounting kit for Promag 10/50/51/53/55/800.
| Code | Description |
| B | Remote, field pipe 3/4 - 3inch |
Grounding Cable DK5GC
Each kit contains 2 cables.
Grounding Ring DK5GD
Contains 1 grounding disk/protection disk. The following are optional nominal diameters and material codes.
| Code | Description |
| 15A | DN15 1/2", 1.4435/316L |
| 15B | DN15 1/2", Alloy C-22 |
| 1FA | DN150 6", 1.4435/316L |
| 1FB | DN150 6", Alloy C-22 |
| 1HA | DN100 4", 1.4435/316L |
| 1HB | DN100 4", Alloy C-22 |
| 1ZA | DN125, 1.4435/316L |
| 1ZB | DN125, Alloy C-22 |
| 25A | DN25 1", 1.4435/316L |
| 25B | DN25 1", Alloy C-22 |
| 2FA | DN250 10", 1.4435/316L |
| 2FB | DN250 10", Alloy C-22 |
| 2HA | DN200 8", 1.4435/316L |
| 2HB | DN200 8", Alloy C-22 |
| 32A | DN32, 1.4435/316L |
| 32B | DN32, Alloy C-22 |
| 3FA | DN350 14", 1.4435/316L |
| 3FB | DN350 14", Alloy C-22 |
| 3HA | DN300 12", 1.4435/316L |
| 3HB | DN300 12", Alloy C-22 |
| 40A | DN40 1 1/2", 1.4435/316L |
| 40B | DN40 1 1/2", Alloy C-22 |
| 4FA | DN450 18", 1.4435/316L |
| 4FB | DN450 18", Alloy C-22 |
| 4HA | DN400 16", 1.4435/316L |
| 4HB | DN400 16", Alloy C-22 |
| 50A | DN50 2", 1.4435/316L |
| 50B | DN50 2", Alloy C-22 |
| 5HA | DN500 20", 1.4435/316L |
| 5HB | DN500 20", Alloy C-22 |
| 65A | DN65, 1.4435/316L |
| 65B | DN65, Alloy C-22 |
| 6HA | DN600 24", 1,4435/316L |
| 6HB | DN600 24", Alloy C-22 |
| 80A | DN80 3", 1.4435/316L |
| 80B | DN80 3", Alloy C-22 |
Lining
| Code | Description |
| 9 | Special version, TSP number must be specified |
| E | PTFE |
Process Connection
| Code | Description |
| 5 | PN16, AS4087 |
| 7 | Table E, AS2129 |
| 9 | Special version, TSP number must be specified |
| A | PN40 EN1092-1(DIN2501) |
| B | PN25 EN1092-1(DIN2501) |
| C | PN16 EN1092-1(DIN2501) |
| D | PN10 EN1092-1(DIN2501) |
| L | Cl.150 ANSI B16.5 |
| M | Cl.300 ANSI B16.5 |
| T | 10K JIS B2220 |
| U | 20K JIS B2220 |
Communication Interface FXA193
The service interface is used to connect the service port of Proline and ToF devices to the RS 232C serial interface (9-pin) of a personal computer.
Delivery Content:
- Service interface with RS 232C connection cable (9-pin)
- FXA "USB" cable, used to provide additional power to FXA193 from the PC's USB port
- Service software ToF Tool-Fieldtool package
| Approval | Description |
| 9 | Special version, TSP number must be specified |
| A | For non-hazardous area |
| B | ATEX II (1) GD |
| C | CSA/FM Class I Div. 1 |
| D | ATEX, CSA, FM |
| Connection Cable | Description |
| 9 | Special version, TSP number must be specified |
| A | Proline devices |
| B | ToF devices |
| E | Proline and ToF devices |
| F | Ex two-wire devices |
| G | Proline devices and Ex two-wire devices |
| H | Proline, ToF and Ex two-wire devices |
| X | No connection cable |