Nr

Order Number

Specification

F

50096745

Power Board 50/51/53 85-260VAC

Kit power s.b. PMAG5X 85-260VAC

F

71039466

Power Board

HE = harsh environment

F

71039466

Power Board

HE = harsh environment

F

50096746

Power Board PMAG5X 85-260VAC Ex

F

71039467

Power Board

HE = harsh environment

F

50096747

Power Board Electromagnetic 50/51/53 20-55VAC 16-62VDC

F

71039468

Power Board

HE = harsh environment

F

50096744

50/51/53 Power Board 20-55VAC 16-62VDC Ex

F

71039469

Power Board

HE = harsh environment

7

50094002

10 pcs 800mA Fuses

Kit 10 fuses 250 VAC T800 MA

7

50094003

10 pcs 2A Fuses

Kit Bus/connec.b.5X/40/8X/65 field hous.

B

50106079

Amplifier Board

Language: FR, ES, IT, NL, PT, DE, EN

B

71039448

Amplifier Board

Language: FR, ES, IT, NL, PT, DE, EN

HE = harsh environment

B

50106081

Amplifier Board

Language: JA, ID, EN

B

71039450

Amplifier Board

Language: JA, ID, EN

HE = harsh environment

B

50106080

Amplifier Board

Language: SV, FI, NO, RU, PL, CS, EN

B

71039449

Amplifier Board

Language: SV, FI, NO, RU, PL, CS, EN

HE = harsh environment

B

50106076

Amplifier Board

Language: FR, ES, IT, NL, PT, DE, EN

B

71039451

Amplifier Board

Language: FR, ES, IT, NL, PT, DE, EN

HE = harsh environment

B

50106073

Signal Amplifier Module

Language: FR, ES, IT, NL, PT, DE, EN

B

71039445

Amplifier Board

Language: FR, ES, IT, NL, PT, DE, EN

HE = harsh environment

B

50106078

Amplifier Board

Language: JA, ID, EN

B

71039453

Amplifier Board

Language: JA, ID, EN

HE = harsh environment

B

50106075

PMAG 50 Amplifier Spare Parts

Language: JA, ID, EN

B

71039447

Amplifier Board

Language: JA, ID, EN

HE = harsh environment

B

50106077

Amplifier Board

Language: SV, FI, NO, RU, PL, CS, EN

B

71039452

Amplifier Board

Language: SV, FI, NO, RU, PL, CS, EN

HE = harsh environment

B

50106074

PMAG 50 Amplifier

Language: SV, FI, NO, RU, PL, CS, EN

B

71039446

Amplifier Board

Language: SV, FI, NO, RU, PL, CS, EN

HE = harsh environment

C

50098302

5X/40/8X/93/65 Output Module

Kit com5X/40/8X/93/65 Iout pass/Freq.Exi

C

71039479

Input/Output Board

50/53/8X

HE = harsh environment

C

50098303

5X/40/8X/93/65 Output Module

Kit com5X/40/8X/93/65 Iout act/Freq.Exi

C

71039478

Input/Output Board

50/53/8X

HE = harsh environment

C

50096759

50/51/40/80/90 Ex Output Module

Kit com50/51/40/80/90 I+F/stat.in+outEx

C

71039473

Input/Output Board

HE = harsh environment

C

50096757

50/40/80/90 Ex Current/Frequency Output Module

Kit com50/40/80/90 curr/Freq.out Ex

C

71039474

Input/Output Board

HE = harsh environment

C

71066579

Input/Output Board PA Ex

50/53/55/80/83/93/65

C

71066580

Input/Output Board

HE = harsh environment

C

50096756

Pline 50/90 Ex Current Output Module

Kit com Pline 50/90 current out Ex

C

71039710

I/O Current Output

HE = harsh environment

C

71021742

Communication Module

C

71039484

Input/Output Board

HE = harsh environment

E

50108132

50/51/80/65 Display Module Version >=1.06.00

Kit display mod 50/51/80/65 >=V1.06.00

J

50108131

Wall Mount Display Module Version >=1.06.00

Kit disp.50/51/80/90/65 Wall >=V1.06.00

21

50094017

5X/8X/9X/65 Wall Mount Bus Interface

Kit Bus PCB/PCB carr.5X/8X/9X/65 wall

G

50094016

5X/40/8X/65 Field Mount Bus Interface

19

50094015

Wall Mount Wiring Module

19

71039496

Wall Mount Terminal Block

HE = harsh environment

18

50094014

Wall Mount Wiring Module

Kit connec. board In/Output Wall encl

A

50098018

Sensor Terminal

Usage:

10/50/51/53/55/400/800

A

71039497

Sensor Terminal

Usage:

10/50/53/55

HE = harsh environment

29

50108139

5X/8X/40/65 Field Mount Terminal Strip

Kit Termin.Block field hous. 5X/8X/40/65

30

50108140

5X/8X/9X/65 Wall Mount Terminal Strip

Kit Termin.Block Wall encl. 5X/8X/9X/65

S

71003946

S-Data Module with Settings

Serialnumber is forceful required

8

50094027

5X/40/8X/93/65 Ex Glass Cover

Kit Cover 5X/40/8X/93/65 with window Exd

8

50094026

5X/40/8X/65 Glass Cover

Kit Cover 5X/40/8X/65 with window

9

50094029

5X/40/8X/93/65 Ex Blind Cover

Kit Cover 5X/40/8X/93/65 vers. blind Exd

9

50094028

5X/40/8X/65 Blind Cover

Kit Cover 5X/40/8X/65 version blind

10

50094040

Flameproof Terminal Compartment Cover

Kit Cover 5X/40/8X/93/65 Conn.termi.Exd

10

50094039

Increased Safety Terminal Compartment Cover

Kit Cover 5X/40/8X/93/65 Conn.termi.Exe

10

50094038

Terminal Compartment Cover

10/5X/40/8X/93/65/92F

26

50094038

Terminal Compartment Cover

10/5X/40/8X/93/65/92F

26

71247838

Service Cover, Remote Version

Usage:

10/5X/8X/8DF/8CN/92F/65/400/800

acc. service info SI01351D-1/06

Consists of:

Cover Rep.kit for G14,

O-Ring 110.00 x 4.50 HNBR, Grease

15

50098036

10 pcs M20x1.5 Ex Cable Glands

Kit 10 cable glands M20x1.5 Ex

15

50098036

10 pcs M20x1.5 Ex Cable Glands

Kit 10 cable glands M20x1.5 Ex

15

50098036

10 pcs M20x1.5 Ex Cable Glands

Kit 10 cable glands M20x1.5 Ex

15

50096840

10 pcs M20x1.5 Cable Glands

Kit 10 cable glands M20x1,5

15

50098040

M20x1.5/PG13.5 Adapter

15

50098042

M20x1.5/NPT 1/2" Adapter

Kit 10 extension M20x1.5/NPT 1/2"

15

50098042

M20x1.5/NPT 1/2" Adapter

Kit 10 extension M20x1.5/NPT 1/2"

15

50098041

M20x1.5/G 1/2" Adapter

Kit 10 extension M20x1.5/G 1/2"

15

50098041

M20x1.5/G 1/2" Adapter

Kit 10 extension M20x1.5/G 1/2"

15

50098037

PA Bus Cable Gland

Kit Cable gland Profibus PA

Kit 10 extension M20x1.5/PG13,5

15

71029351

Cable Gland

15

71029352

Cable Gland

12

50096839

Circuit Board Holder (Field/Stainless Steel Housing)

Kit Circuit board cpl field/SS-housing

14

50099102

Cast Aluminum/Stainless Steel Housing Sleeve

13

50096841

Ground Terminal/Cover Clamp

Kit Ground terminal / Cover clamp

20

50094041

Wall Mount Seal Cover

Kit Seal cover to Wall enclosure

11

50094050

Field Mount Seal Cover

Kit 10 Seal cover to field housing

22

50098020

Mounting Screws and Mounting Accessories

Usage:

10/23/50/51/53/55

Sensor: D/E/H/L/P/S/W

24

50098019

Mounting Screws and Mounting Accessories

Usage:

10/50/51/53/55/400/800

Sensor: D/E/H/L/P/S/W

25

50098023

Gasket

Usage:

10/50/51/53/55/400/800

Sensor: D/E/L/P/S/W

23

50098024

Gasket

Usage:

10/23/50/51/53/55

Sensor: D/E/L/P/S/W

DK5CA-

Promag 10/50/51/53/55 Remote Version Cable DK5CA

10/50/51/53/55/400/800

1 kit includes 1 coil cable and

1 signal cable

Cable, Remote Version:

1

5m/15ft

2

10m/30ft

4

..... m

5

..... ft

Approval:

A

Non-hazardous area + ATEX II 3G, FM/CSA

B

ATEX II2GD, TIIS Zone 1

50XXX-

**Promag 50 Transmitter 50XXX

Application:

XXX

Promag 50W, 50P, 50H, 50D, 50L, 50E

Version:

XX

Transmitter only

Approval:

A

Non-hazardous area

B

ATEX II 2GD+ IECEx Z1,21; Ex d wiring, Ex deia IIC, Ex tD A21 Z=Zone

D

ATEX II 2GD+ IECEx Z1,21; Ex e wiring, Ex deia IIC, Ex tD A21 Z=Zone

J

ATEX II 3G Ex nA nC IIC

N

FM XP Cl. I Div. 1 / CSA Cl. I Div. 1

R

FM NI Cl. I Div. 2 / CSA Cl. I Div. 2

Housing:

1

Compact Alu, IP67 NEMA4X, -40oC/oF Sensor see specification

3

Wall Alu, IP67 NEMA4X, -40oC/oF Sensor see specification

9

Special version, TSP-no. to be spec.

A

Compact Alu, IP67 NEMA4X

C

Wall Alu, IP67 NEMA4X

G

Field Alu, IP67 NEMA4X

P

Compact Alu, IP67 NEMA4X, HE HE= harsh environment

S

Wall Alu, IP67 NEMA4X, HE HE= harsh environment

T

Field Alu, IP67 NEMA4X, HE HE= harsh environment

Cable, Remote Version:

0

Not used

1

5m/15ft coil and signal cable

2

10m/30ft coil and signal cable

4

..... m coil and signal cable

5

..... ft coil and signal cable

9

Special version, TSP-no. to be spec.

Cable Entry:

9

Special version, TSP-no. to be spec.

A

Gland M20 (EEx d > thread M20)

B

Thread NPT 1/2

C

Thread G 1/2

K

Bus plug + gland M20

L

Bus plug + thread NPT 1/2

M

Bus plug + thread G 1/2

Power Supply; Display:

7

85-260VAC, WEA, w/o display, Remote configuration WEA= language DE+EN+FR+IT+ES+PT+NL

8

20-55VAC / 16-62VDC, WEA, w/o display, Remote configuration WEA= language DE+EN+FR+IT+ES+PT+NL

9

Special version, TSP-no. to be spec.

A

85-260VAC, WEA, 2-line + push buttons, WEA= language DE+EN+FR+IT+ES+PT+NL

B

20-55VAC / 16-62VDC, WEA, 2-line + push buttons, WEA= language DE+EN+FR+IT+ES+PT+NL

C

85-260VAC, SEA, 2-line + push buttons, SEA= language JA+ID+EN

D

20-55VAC / 16-62VDC, SEA, 2-line + push buttons, SEA= language JA+ID+EN

E

85-260VAC, EES, 2-line + push buttons, EES= language SV+FI+NO+RU+PL+CS+EN

F

20-55VAC / 16-62VDC, EES, 2-line + push buttons, EES= language SV+FI+NO+RU+PL+CS+EN

Adjustment; Software Feature:

A

Factory setup; basic version

C

Factory setup; ECC electrode cleaning circuit

Output, Input:

A

4-20mA SIL HART + frequency

D

4-20mA SIL HART + freq.+ status+stat.In

H

PROFIBUS PA

J

PROFIBUS DP

S

4-20mA SIL HART active + freq., Ex-i, freq. = passive

T

4-20mA SIL HART passive + freq., Ex-i, freq. = passive

W

4-20mA SIL HART

DK5WM-

Promag10/50/51/53/55 Transmitter Mounting Kit DK5WM

10/50/51/53/55/800

Application:

A

Remote, wall / pipe mounting, panel

B

Remote, field Tube 3/4 - 3inch

DK5GC-

Grounding Cable DK5GC

A kit includes 2 cables

Nominal Diameter:

15

DN15 1/2"

1F

DN150 6"

1H

DN100 4"

1Z

DN125

25

DN25 1"

2F

DN250 10"

2H

DN200 8"

32

DN32

3F

DN350 - DN2000

3H

DN300 12"

40

DN40 1-1/2"

50

DN50 2"

65

DN65

80

DN80 3"

Process Connection:

5

PN16, AS4087

7

Table E, AS2129

A

PN40 EN1092-1(DIN2501)

B

PN25 EN1092-1(DIN2501)

C

PN16 EN1092-1(DIN2501)

D

PN1016 EN1092-1(DIN2501)

L

Cl.150 ANSI B16.5

M

Cl.300 ANSI B16.5

T

10K JIS B2220

U

20K JIS B2220

DK5GD-

Grounding Ring DK5GD

Includes 1 grounding disc/protection

disc

Nominal Diameter:

15A

DN15 1/2", 1.4435/316L

15B

DN15 1/2", Alloy C-22

15D

DN15 1/2", Titanium

15E

DN15 1/2", Tantalum

1FA

DN150 6", 1.4435/316L

1FB

DN150 6", Alloy C-22

1FD

DN150 6", Titanium

1FE

DN150 6", Tantalum

1HA

DN100 4", 1.4435/316L

1HB

DN100 4", Alloy C-22

1HD

DN100 4", Titanium

1HE

DN100 4", Tantalum

1ZA

DN125, 1.4435/316L

1ZB

DN125, Alloy C-22

1ZD

DN125, Titanium

1ZE

DN125, Tantalum

25A

DN25 1", 1.4435/316L

25B

DN25 1", Alloy C-22

25D

DN25 1", Titanium

25E

DN25 1", Tantalum

2FA

DN250 10", 1.4435/316L

2FB

DN250 10", Alloy C-22

2FD

DN250 10", Titanium

2FE

DN250 10", Tantalum

2HA

DN200 8", 1.4435/316L

2HB

DN200 8", Alloy C-22

2HD

DN200 8", Titanium

2HE

DN200 8", Tantalum

32A

DN32, 1.4435/316L

32B

DN32, Alloy C-22

32D

DN32, Titanium

32E

DN32, Tantalum

3FA

DN350 14", 1.4435/316L

3FB

DN350 14", Alloy C-22

3HA

DN300 12", 1.4435/316L

3HB

DN300 12", Alloy C-22

3HD

DN300 12", Titanium

3HE

DN300 12", Tantalum

40A

DN40 1 1/2", 1.4435/316L

40B

DN40 1 1/2", Alloy C-22

40D

DN40 1 1/2", Titanium

40E

DN40 1 1/2", Tantalum

4FA

DN450 18", 1.4435/316L

4FB

DN450 18", Alloy C-22

4HA

DN400 16", 1.4435/316L

4HB

DN400 16", Alloy C-22

50A

DN50 2", 1.4435/316L

50B

DN50 2", Alloy C-22

50D

DN50 2", Titanium

50E

DN50 2", Tantalum

5HA

DN500 20", 1.4435/316L

5HB

DN500 20", Alloy C-22

65A

DN65, 1.4435/316L

65B

DN65, Alloy C-22

65D

DN65, Titanium

65E

DN65, Tantalum

6HA

DN600 24", 1,4435/316L

6HB

DN600 24", Alloy C-22

80A

DN80 3", 1.4435/316L

80B

DN80 3", Alloy C-22

80D

DN80 3", Titanium

80E

DN80 3", Tantalum

Liner:

9

Special version, TSP-no. to be spec.

A

PFA

E

PTFE

Process Connection:

5

PN16, AS4087

7

Table E, AS2129

9

Special version, TSP-no. to be spec.

A

PN40 EN1092-1(DIN2501)

B

PN25 EN1092-1(DIN2501)

C

PN16 EN1092-1(DIN2501)

D

PN10 EN1092-1(DIN2501)

L

Cl.150 ANSI B16.5

M

Cl.300 ANSI B16.5

T

10K JIS B2220

U

20K JIS B2220

FXA193-

Communication Interface FXA193

The service interface connects the

service port of Proline and ToF devices

with the serial interface RS 232C

(9 pin.) of a personal computer.

Contents of delivery:

- Serviceinterface with RS 232C

connection cable (9 pin.)

- FXA "USB" cable, the additional

power supply for FXA193 from USB-port

of the PC.

- Service Softw.ToF Tool-Fieldtool

Package

Approval:

9

Special version, TSP-no. to be spec.

A

For use in non-hazardous area

B

ATEX II (1) GD

C

CSA/FM Class I Div. 1

D

ATEX, CSA, FM

Connection Cable:

9

Special version, TSP-no. to be spec.

A

Proline device

B

ToF device

E

Proline and ToF device

F

Ex two-wire device

G

Proline device and Ex two-wire device

H

Proline, ToF and Ex two-wire device

X