Nr

Order number

Specification

31

71323007

Power supply unit

Usage:

Promag/Promass 300/500,

Prosonic Flow/t-mass 300,

transmitter housing,

electronic compartment.

31

71323008

Power supply unit

Usage:

Promag/Promass 300/500,

Prosonic Flow/t-mass 300,

transmitter housing,

electronic compartment.

31

71323009

Power supply unit

Usage:

Promag/Promass/Prosonic Flow/

t-mass/Teqwave MW 300/500 digital,

Non-haz, Zone 2,

transmitter housing,

electronic compartment.

47

71323012

Main electronics connection board assembly, Ex, Promass 500 digital

Usage:

Promass/t-mass 500 digital,

transmitter housing,

electronic compartment.

47

71323013

Main electronics connection board assembly, Non-haz, 500 digital

Usage:

Promag/Promass/Prosonic Flow/

t-mass/Teqwave MW 500 digital,

transmitter housing,

electronic compartment.

36

71323015

ISEM connection board assembly, Ex, 500 digital

Usage:

Promag/Promass/t-mass/

Teqwave MW 500 digital,

sensor connection housing.

33

XPD0028-

300/500 ISEM electronic insert

Usage:

Promass, Cubemass 300/500

BA

A

B

AB

00

AA

BB

BD

BJ

BL

BN

BS

C2

C4

C6

CD

CN

CS

CZ

GB

GD

GJ

GL

GN

GR

GS

JD

JJ

KB

KD

MB

MD

MJ

ML

MN

MS

NB

ND

NJ

NL

NN

NS

UB

UD

UJ

UL

UN

UR

US

99

BB

BF

HA

HB

HC

HD

SA

00

JP

39

71185788

T-DAT module

34

XPD0037-

I/O module

Usage:

Proline 300/500

AA

A1

B1

C1

D1

E1

F1

G1

H1

K1

00

01

37

71323010

Module cartridge, 300/500, Ex

Usage:

transmitter housing,

electronic compartment.

Consists of:

module cartridge incl.

interconnection board.

46

71323005

Ribbon cable assembly

Usage:

Promag/Promass 300/500,

t-mass/Teqwave MW 300,

transmitter housing.

46

71323006

Ribbon cable assembly

Usage:

Promag/Promass/t-mass/

Teqwave MW 500 digital,

sensor connection housing.

35

XPD0038-

I/O module

Usage:

Proline 300/500

AA

1A

1B

1C

1D

00

45

71323075

Terminal assembly

Usage:

transmitter housing Alu/cast,

connection compartment.

Option A =

HART, PROFIBUS PA, FOUNDATION Fieldbus.

Consists of:

2x connection terminal 2-pin,

1x connection terminal 4-pin.

50

XPD0031-

Display module

Usage:

Proline 300/500, DKX001.

BA

A

B

F

G

00

45

71323076

Terminal assembly

Usage:

transmitter housing Alu/cast,

connection compartment.

Option B =

EtherNet, PROFINET.

Consists of:

2x connection terminal 2-pin.

45

71327819

Terminal assembly

Usage:

transmitter housing Alu/cast,

connection compartment.

Option C =

PROFIBUS DP, Modbus RS485.

Consists of:

2x connection terminal 2-pin,

1x connection terminal 4-pin.

45

71323077

Terminal assembly

Usage:

transmitter housing Alu/polycarbonate,

connection compartment.

Option A =

HART, PROFIBUS PA, FOUNDATION Fieldbus.

Consists of:

1x connection terminal 2-pin,

1x connection terminal 3-pin,

1x connection terminal 4-pin,

1x connection terminal 6-pin.

45

71323078

Terminal assembly

Usage:

transmitter housing Alu/polycarbonate,

connection compartment.

Option B =

EtherNet, PROFINET.

Consists of:

1x connection terminal 3-pin,

1x connection terminal 4-pin,

1x connection terminal 6-pin.

45

71327820

Terminal assembly

Usage:

transmitter housing Alu/polycarbonate,

connection compartment.

Option C =

PROFIBUS DP, Modbus RS485.

Consists of:

1x connection terminal 2-pin,

1x connection terminal 3-pin,

1x connection terminal 4-pin,

1x connection terminal 6-pin.

44

71323268

Connection board assembly

Usage:

Sensor connection housing.

Consists of:

connection board,

O-Ring 26.00x1.50 HNBR.

44

71323269

Connection board assembly

Usage:

Sensor connection housing.

Consists of:

connection board,

O-Ring 26.00x1.50 FVMQ, -50oC/-58oF.

20

71323016

Cover assembly

Usage:

Promag/Promass/Prosonic Flow/t-mass/

Teqwave MW 300, Prosonic Flow 500,

transmitter housing Alu, Non-haz.

Promag/Promass 300,

Promag/Promass/Prosonic Flow 500,

transmitter housing Alu, Ex.

Consists of:

cover sight glass, Alu,

O-Ring 110.7x3.53 HNBR.

20

71323017

Cover assembly

Usage:

Promass/Prosonic Flow/t-mass 300,

transmitter housing Alu, Non-haz.

Promass 300,

Promag/Promass/Prosonic Flow 500,

transmitter housing Alu, Ex.

Consists of:

cover sight glass, Alu,

O-Ring 110.7x3.53 FVMQ, -50oC/-58oF.

20

71323020

Aluminum cover assembly with sight glass

Usage:

Promag/Promass/Prosonic Flow/t-mass 300,

Promag/Promass/Prosonic Flow 500,

transmitter housing Alu, Ex.

Consists of:

cover sight glass, Alu,

O-Ring 110.7x3.53 HNBR.

20

71323021

Cover assembly

Usage:

Promass/Prosonic Flow/t-mass 300,

Promag/Promass/Prosonic Flow 500,

transmitter housing Alu, Ex.

Consists of:

cover sight glass, Alu,

O-Ring 110.7x3.53 FVMQ, -50oC/-58oF.

20

71323024

Cover assembly

Usage:

Promass/Prosonic Flow 300,

Promag/Promass/Prosonic Flow 500,

transmitter housing cast, Ex.

Consists of:

cover sight glass, cast,

O-Ring 110.7x3.53 HNBR.

20

71323025

Cover assembly

Usage:

Promass/Prosonic Flow 300,

Promag/Promass/Prosonic Flow 500,

transmitter housing cast, Ex.

Consists of:

cover sight glass cast,

O-Ring 110.7x3.53 FVMQ, -50oC/-58oF.

70

71323026

Cover assembly

Usage:

Promag/Promass/Prosonic Flow/t-mass/

Teqwave MW 300,

Promag/Promass/Prosonic Flow 500,

transmitter housing Alu/cast.

Consists of:

10x O-Ring 110.7x3.53 HNBR.

70

71323027

Cover assembly

Usage:

Promass/Prosonic Flow/t-mass 300,

Promag/Promass/Prosonic Flow 500,

transmitter housing Alu/cast,

Consists of:

O-Ring 110.7x3.53 FVMQ, -50oC/-58oF.

22

71323032

Cover assembly

Usage:

Promag/Promass/Prosonic Flow/t-mass 300,

Promag/Promass/Prosonic Flow 500,

transmitter housing Alu, Ex.

Consists of:

cover Alu,

O-Ring 120.2x3.53 HNBR.

22

71323033

Cover assembly

Usage:

Promass/Prosonic Flow/t-mass 300,

Promag/Promass/Prosonic Flow 500,

transmitter housing Alu, Ex.

Consists of:

cover Alu,

O-Ring 120.2x3.53 FVMQ, -50oC/-58oF.

22

71323034

Cover assembly

Usage:

Promass/Prosonic Flow 300,

Promag/Promass/Prosonic Flow 500,

transmitter housing cast, Ex.

Consists of:

cover cast,

O-Ring 120.2x3.53 HNBR.

22

71323035

Cover assembly

Usage:

Promass/Prosonic Flow 300,

Promag/Promass/Prosonic Flow 500,

transmitter housing cast, Ex.

Consists of:

cover cast,

O-Ring 120.2x3.53 FVMQ, -50oC/-58oF.

74

71323036

Cover assembly

Usage:

Promag/Promass/Prosonic Flow/t-mass 300,

Promag/Promass/Prosonic Flow 500,

transmitter housing Alu/cast, Ex.

Consists of:

10x O-Ring 120.2x3.53 HNBR.

74

71323037

Cover assembly

Usage:

Promass/Prosonic Flow/t-mass 300,

Promag/Promass/Prosonic Flow 500,

transmitter housing Alu/cast, Ex.

Consists of:

O-Ring 120.2x3.53 FVMQ, -50oC/-58oF.

23

71323038

Housing cover assembly

Usage:

Promag 10,

Promag/Promass/Prosonic Flow 500,

wall mount transmitter Alu,

connection compartment.

Consists of:

cover Alu,

O-Ring 88.50x3.53 HNBR.

23

71323039

Cover assembly

Usage:

Promag/Promass/Prosonic Flow 500,

wall mount transmitter Alu, Ex,

connection compartment.

Consists of:

cover Alu,

O-Ring 88.50x3.53 FVMQ, -50oC/-58oF.

23

71323040

Cover assembly

Usage:

Promag/Promass/Prosonic Flow 500,

wall mount transmitter cast, Ex,

connection compartment.

Consists of:

cover cast,

O-Ring 88.50x3.53 HNBR.

23

71323041

Cover assembly

Usage:

Promag/Promass/Prosonic Flow 500,

wall mount transmitter cast, Ex,

connection compartment.

Consists of:

cover cast,

O-Ring 88.50x3.53 FVMQ, -50oC/-58oF.

75

71323042

Housing cover seal

Usage:

Promag 10,

Promag/Promass/Prosonic Flow 500,

wall mount transmitter Alu/cast,

connection compartment.

Consists of:

10x O-Ring 88.50x3.53 HNBR.

75

71323043

Cover assembly

Usage:

Promag/Promass/Prosonic Flow 500,

wall mount transmitter Alu/cast, Ex,

connection compartment.

Consists of:

O-Ring 88.50x3.53 FVMQ, -50oC/-58oF.

20

71384170

Promag400/500 housing cover

Usage:

Prosonic Flow 400, Promag 400(C),

(C) = generation index C,

Promag/Promass/Prosonic Flow/t-mass/

Teqwave MW 500 digital,

transmitter housing Alu.

Consists of:

cover Alu complete included

O-Ring 196.40x3.53 HNBR,

default and -50oC/-58oF,

wire with screw lock 1.5x150.

20

71408508

Housing cover

Usage:

Prosonic Flow 400,

Promag/Promass/Prosonic Flow/t-mass/

Teqwave MW 500 digital, Promag 800(C),

(C) = generation index C,

transmitter housing polycarbonate.

Consists of:

cover polycarbonate complete,

O-Ring 196.44x3.53 VMQ,

default and -50oC/-58oF,

wire with screw lock 1.5x150.

70

71278078

Housing cover seal

Usage:

Prosonic Flow 400, Promag 400(C),

(C) = generation index C,

Promag/Promass/Prosonic Flow/t-mass/

Teqwave MW 500 digital,

transmitter housing Alu.

Consists of:

10x O-Ring 196.40x3.53 HNBR,

default and -50oC/-58oF.

70

71278077

Housing cover polycarbonate gasket

Usage:

Prosonic Flow 400,

Promag/Promass/Prosonic Flow/t-mass/

Teqwave MW 500 digital,

Promag 400/800(C),

(C) = generation index C,

transmitter housing polycarbonate.

Consists of:

10x O-Ring 196.44x3.53 VMQ.

24

71228796

Housing cover assembly

Usage:

Promag 10/500,

Promag/Promass/Prosonic Flow/t-mass/

Teqwave MW 500 digital,

Promag 400/800(C),

(C) = generation index C,

sensor connection housing.

Consists of:

cover Alu,

O-Ring 113.90x3.53 HNBR.

24

71323050

Cover assembly

Usage:

Promass/Prosonic Flow/t-mass 500digital,

sensor connection housing.

Consists of:

cover Alu,

O-Ring 113.90x3.53 FVMQ, -50oC/-58oF.

73

71323051

Housing seal assembly

Usage:

Promass/Prosonic Flow/t-mass 500digital,

sensor connection housing.

Consists of:

O-Ring 113.90x3.53 HNBR for cover,

gasket EPDM for housing/sensor.

73

71323052

Housing seal assembly

Usage:

Promass/Prosonic Flow/t-mass 500digital,

sensor connection housing.

Consists of:

O-Ring 113.90x3.53 FVMQ for cover,

-50oC/-58oF,

gasket FVMQ for housing/sensor,

-50oC/-58oF.

24

71323053

Cover assembly

Usage:

Promass 500,

Promag/Promass 500 digital,

sensor connection housing.

Consists of:

cover stainless 1.4301,

gasket EPDM for cover.

24

71323054

Cover assembly

Usage:

Promass 500,

Promass 500 digital,

sensor connection housing.

Consists of:

cover stainless 1.4301,

gasket FVMQ for cover, -50oC/-58oF.

73

71323057

Housing seal assembly

Usage:

Promass 500,

Promass 500 digital,

sensor connection housing.

Consists of:

gasket EPDM for cover,

gasket EPDM for housing/sensor.

73

71323058

Housing seal assembly

Usage:

Promass 500,

Promass 500 digital,

sensor connection housing.

Consists of:

gasket FVMQ for cover, -50oC/-58oF,

gasket FVMQ for housing/sensor,

-50oC/-58oF.

24

71185793

Stainless steel housing cover

Usage:

Promag/Promass 100,

Promag/Promass 500 digital,

sensor connection housing.

Consists of:

cover stainless 1.4301,

gasket EPDM for cover.

24

71323060

Cover assembly

Usage:

Promass 500 digital,

sensor connection housing.

Consists of:

cover stainless 1.4301,

gasket FVMQ for cover, -50oC/-58oF.

73

71185799

Housing seal

Usage:

Promass 100,

Promass 500 digital,

sensor connection housing.

Consists of:

gasket EPDM for cover,

gasket EPDM for housing/sensor.

73

71323062

Housing seal assembly

Usage:

Promass 500 digital,

sensor connection housing stainless.

Consists of:

gasket FVMQ for cover, -50oC/-58oF,

gasket FVMQ for housing/sensor,

-50oC/-58oF.

24

71323063

Cover assembly

Usage:

Promag/Promass 500,

Promag/Promass/Prosonic Flow/t-mass

500 digital, sensor connection housing.

Consists of:

cover cast,

O-Ring 120.2x3.53 HNBR.

24

71323064

Cover assembly

Usage:

Promass 500,

Promass/Prosonic Flow/t-mass 500digital,

sensor connection housing.

Consists of:

cover cast,

O-Ring 120.2x3.53 FVMQ, -50oC/-58oF.

73

71323065

Housing seal assembly

Usage:

Promass 500,

Promass/Prosonic Flow/t-mass 500digital,

sensor connection housing.

Consists of:

O-Ring 120.2x3.53 HNBR for cover,

O-Ring 88.50x3.53HNBR for housing/sensor

73

71323066

Housing seal assembly

Usage:

Promass 500,

Promass/Prosonic Flow/t-mass 500digital,

sensor connection housing.

Consists of:

O-Ring 120.2x3.53 FVMQ for cover,

-50oC/-58oF,

O-Ring 88.50x3.53 FVMQ for hous./sensor,

-50oC/-58oF.

71

71323071

Interface seal assembly

Usage:

Promass/Prosonic Flow/t-mass/

Teqwave MW 300,

Promass/Prosonic Flow 500,

transmitter housing/sensor or

transmitter housing/wall mount.

Consists of:

5x O-Ring 88.50x3.53 HNBR for

interface.

71

71323072

Interface seal assembly

Usage:

Promass/Prosonic Flow/t-mass 300,

Promass/Prosonic Flow 500,

transmitter housing/sensor or

transmitter housing/wall mount.

Consists of:

O-Ring 88.50x3.53 FVMQ for

interface, -50oC/-58oF.

11

71323081

Protective cover assembly

Usage:

transmitter housing Alu/cast,

connection compartment.

Option A =

HART, PROFIBUS PA, PROFIBUS DP,

Modbus RS485, FOUNDATION Fieldbus.

Consists of:

Connection compartment protective cover,

display carrier, 2x screw M4x10.

11

71323082

Protective cover assembly

Usage:

transmitter housing Alu/cast,

connection compartment.

Option B =

EtherNet, PROFINET.

Consists of:

Connection compartment protective cover,

display carrier, 2x screw M4x10.

13

71276494

Clamp fastening, screw

Usage: Promass 100, Promag 100,

Prosonic Flow E 100/E Heat,

CNGmass, LPGmass, LNGmass,

Promag/Promass 500, Promag 10,

Promag/Promass/Prosonic Flow/t-mass/

Teqwave MW 500 digital,

Promag 400/800(C),

(C) = generation index C,

sensor connection housing.

Consists of:

cover clamp, screw M4x16.

71450719

Adapter M12, RJ45, L= 80mm (suitable for t-mass F 300/50

Usage:

Proline 300/500.

71450719

Adapter M12, RJ45, L= 80mm (suitable for t-mass F 300/50

Usage:

Proline 300/500.

71450719

Adapter M12, RJ45, L= 80mm (suitable for t-mass F 300/50

Usage:

Proline 300/500.

71450719

Adapter M12, RJ45, L= 80mm (suitable for t-mass F 300/50

Usage:

Proline 300/500.

71450719

Adapter M12, RJ45, L= 80mm (suitable for t-mass F 300/50

Usage:

Proline 300/500.

71450719

Adapter M12, RJ45, L= 80mm (suitable for t-mass F 300/50

Usage:

Proline 300/500.

71450719

Adapter M12, RJ45, L= 80mm (suitable for t-mass F 300/50

Usage:

Proline 300/500.

71450719

Adapter M12, RJ45, L= 80mm (suitable for t-mass F 300/50

Usage:

Proline 300/500.

82

71228792

Display protective cover

Usage:

Prosonic Flow 400, Promag 400(C),

(C) = generation index C,

Promag/Promass/Prosonic Flow/t-mass/

Teqwave MW 500 digital,

transmitter housing Alu.

Consists of:

display protection 1.4301,

installation material.

87

71343504

Protective housing assembly

Usage:

Promag/Promass/Prosonic Flow/t-mass/

Teqwave MW 400/800/500 digital,

transmitter housing.

Consists of:

weather protection cover 4404.

87

71343505

Protective housing assembly

Usage:

Promag/Promass/Prosonic Flow/t-mass/

Teqwave MW 300,

Promag/Promass/Prosonic Flow 500,

transmitter housing.

Consists of:

weather protection cover 4404,

installation material.

71346427

Pipe mounting assembly

For Product:

Promag 500 digital

Promass 500 digital

t-mass 500 digital

Prosonic Flow 500 digital

Teqwave MW 500 digital

Prosonic Flow 400

71346428

Pipe mounting assembly

71351317

Wireless receiver for extended distance

Consists of:

Connection cable in the transmitter,

Ex cable entry for antenna,

1.5m cable,

antenna,

angle with union nut.

71392563

Coriolis mass flowmeter sensor bracket

Usage:

Promass A, 8A2B**, 8A3C**, 8A5C**.

Consists of:

1x sensor holder 1.4404

3x holder bracket 1.4404

2x screw M8x50 INOX A4

2x spring washer M8 INOX A4.

8X5BXX-

Transmitter mass flowmeter 500, 8X5BXX

With an integrated web server.

AA

BB

BD

BJ

BL

BN

BS

C2

C4

C6

CD

CN

CS

CZ

GB

GD

GJ

GL

GN

GR

GS

JD

JJ

KB

KD

MB

MD

MJ

ML

MN

MS

NB

ND

NJ

NL

NN

NS

UB

UD

UJ

UL

UN

UR

US

9

D

E

I

99

BA

CA

CC

GA

HA

LA

MA

NA

RA

RB

RC

SA

TA

9

A

B

C

D

E

F

G

H

I

J

9

A

B

C

D

E

F

G

H

I

J

9

A

B

C

D

E

G

H

I

J

9

F

G

9

A

B

9

A

D

L

9

A

B

E

F

J

L

3

4

5

6

9

A

B

C

D

L

M

N

P

R

S

T

U

V

AA

00

AB

00

99

BB

BF

HA

HB

HC

HD

SA

A1

A2

AA

AB

AC

AD

AE

AF

AG

AH

AI

AJ

AK

AL

AM

AQ

AR

AT

CM

E9

EA

EB

ED

EL

I7

I9

JP

K9

L9

LA

N9

NB

P7

P8

P9

PB

PV

58

60

61

64

65

66

67

68

70

71

72

73

74

75

76

77

78

Z1

Z2

DK8013-

Promass 500, sensor cable

Connection cable (analog and digital)

between sensor connection housing

and transmitter for remote versions

of Proline 500.

AA

BB

BD

BJ

BL

BN

BS

C2

C4

C6

CD

CN

CS

CZ

GB

GD

GJ

GL

GN

GR

GS

JD

JJ

KB

KD

MB

MD

MJ

ML

MN

MS

NB

ND

NJ

NL

NN

NS

UB

UD

UJ

UL

UN

UR

US

AA

A

B

9

A

B

C

L

1

2

3

9

B

E

F

J

L

JP

K9

DK8003-

Mass sensor, heat jacket, DK8003

Heating medium (e.g. water, steam)

01

02

04

AB

S

RB

RC

RD

RE

RF

RG

RH

00

A1

JB

JC

XPRFID-

Spare RFID TAG

Consists of:

RFID TAG, fixing wire, crimp sleeve.

AA

BA

CA

IA

KA

MA

NA

UA

UR

1