Nr
Order number
Specification
31
71323007
Power supply unit
Usage:
Promag/Promass 300/500,
Prosonic Flow/t-mass 300,
transmitter housing,
electronic compartment.
31
71323008
Power supply unit
Usage:
Promag/Promass 300/500,
Prosonic Flow/t-mass 300,
transmitter housing,
electronic compartment.
31
71323009
Power supply unit
Usage:
Promag/Promass/Prosonic Flow/
t-mass/Teqwave MW 300/500 digital,
Non-haz, Zone 2,
transmitter housing,
electronic compartment.
47
71323012
Main electronics connection board assembly, Ex, Promass 500 digital
Usage:
Promass/t-mass 500 digital,
transmitter housing,
electronic compartment.
47
71323013
Main electronics connection board assembly, Non-haz, 500 digital
Usage:
Promag/Promass/Prosonic Flow/
t-mass/Teqwave MW 500 digital,
transmitter housing,
electronic compartment.
36
71323015
ISEM connection board assembly, Ex, 500 digital
Usage:
Promag/Promass/t-mass/
Teqwave MW 500 digital,
sensor connection housing.
33
XPD0028-
300/500 ISEM electronic insert
Usage:
Promass, Cubemass 300/500
BA
A
B
AB
00
AA
BB
BD
BJ
BL
BN
BS
C2
C4
C6
CD
CN
CS
CZ
GB
GD
GJ
GL
GN
GR
GS
JD
JJ
KB
KD
MB
MD
MJ
ML
MN
MS
NB
ND
NJ
NL
NN
NS
UB
UD
UJ
UL
UN
UR
US
99
BB
BF
HA
HB
HC
HD
SA
00
JP
39
71185788
T-DAT module
34
XPD0037-
I/O module
Usage:
Proline 300/500
AA
A1
B1
C1
D1
E1
F1
G1
H1
K1
00
01
37
71323010
Module cartridge, 300/500, Ex
Usage:
transmitter housing,
electronic compartment.
Consists of:
module cartridge incl.
interconnection board.
46
71323005
Ribbon cable assembly
Usage:
Promag/Promass 300/500,
t-mass/Teqwave MW 300,
transmitter housing.
46
71323006
Ribbon cable assembly
Usage:
Promag/Promass/t-mass/
Teqwave MW 500 digital,
sensor connection housing.
35
XPD0038-
I/O module
Usage:
Proline 300/500
AA
1A
1B
1C
1D
00
45
71323075
Terminal assembly
Usage:
transmitter housing Alu/cast,
connection compartment.
Option A =
HART, PROFIBUS PA, FOUNDATION Fieldbus.
Consists of:
2x connection terminal 2-pin,
1x connection terminal 4-pin.
50
XPD0031-
Display module
Usage:
Proline 300/500, DKX001.
BA
A
B
F
G
00
45
71323076
Terminal assembly
Usage:
transmitter housing Alu/cast,
connection compartment.
Option B =
EtherNet, PROFINET.
Consists of:
2x connection terminal 2-pin.
45
71327819
Terminal assembly
Usage:
transmitter housing Alu/cast,
connection compartment.
Option C =
PROFIBUS DP, Modbus RS485.
Consists of:
2x connection terminal 2-pin,
1x connection terminal 4-pin.
45
71323077
Terminal assembly
Usage:
transmitter housing Alu/polycarbonate,
connection compartment.
Option A =
HART, PROFIBUS PA, FOUNDATION Fieldbus.
Consists of:
1x connection terminal 2-pin,
1x connection terminal 3-pin,
1x connection terminal 4-pin,
1x connection terminal 6-pin.
45
71323078
Terminal assembly
Usage:
transmitter housing Alu/polycarbonate,
connection compartment.
Option B =
EtherNet, PROFINET.
Consists of:
1x connection terminal 3-pin,
1x connection terminal 4-pin,
1x connection terminal 6-pin.
45
71327820
Terminal assembly
Usage:
transmitter housing Alu/polycarbonate,
connection compartment.
Option C =
PROFIBUS DP, Modbus RS485.
Consists of:
1x connection terminal 2-pin,
1x connection terminal 3-pin,
1x connection terminal 4-pin,
1x connection terminal 6-pin.
44
71323268
Connection board assembly
Usage:
Sensor connection housing.
Consists of:
connection board,
O-Ring 26.00x1.50 HNBR.
44
71323269
Connection board assembly
Usage:
Sensor connection housing.
Consists of:
connection board,
O-Ring 26.00x1.50 FVMQ, -50oC/-58oF.
20
71323016
Cover assembly
Usage:
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 300, Prosonic Flow 500,
transmitter housing Alu, Non-haz.
Promag/Promass 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing Alu, Ex.
Consists of:
cover sight glass, Alu,
O-Ring 110.7x3.53 HNBR.
20
71323017
Cover assembly
Usage:
Promass/Prosonic Flow/t-mass 300,
transmitter housing Alu, Non-haz.
Promass 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing Alu, Ex.
Consists of:
cover sight glass, Alu,
O-Ring 110.7x3.53 FVMQ, -50oC/-58oF.
20
71323020
Aluminum cover assembly with sight glass
Usage:
Promag/Promass/Prosonic Flow/t-mass 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing Alu, Ex.
Consists of:
cover sight glass, Alu,
O-Ring 110.7x3.53 HNBR.
20
71323021
Cover assembly
Usage:
Promass/Prosonic Flow/t-mass 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing Alu, Ex.
Consists of:
cover sight glass, Alu,
O-Ring 110.7x3.53 FVMQ, -50oC/-58oF.
20
71323024
Cover assembly
Usage:
Promass/Prosonic Flow 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing cast, Ex.
Consists of:
cover sight glass, cast,
O-Ring 110.7x3.53 HNBR.
20
71323025
Cover assembly
Usage:
Promass/Prosonic Flow 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing cast, Ex.
Consists of:
cover sight glass cast,
O-Ring 110.7x3.53 FVMQ, -50oC/-58oF.
70
71323026
Cover assembly
Usage:
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing Alu/cast.
Consists of:
10x O-Ring 110.7x3.53 HNBR.
70
71323027
Cover assembly
Usage:
Promass/Prosonic Flow/t-mass 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing Alu/cast,
Consists of:
O-Ring 110.7x3.53 FVMQ, -50oC/-58oF.
22
71323032
Cover assembly
Usage:
Promag/Promass/Prosonic Flow/t-mass 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing Alu, Ex.
Consists of:
cover Alu,
O-Ring 120.2x3.53 HNBR.
22
71323033
Cover assembly
Usage:
Promass/Prosonic Flow/t-mass 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing Alu, Ex.
Consists of:
cover Alu,
O-Ring 120.2x3.53 FVMQ, -50oC/-58oF.
22
71323034
Cover assembly
Usage:
Promass/Prosonic Flow 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing cast, Ex.
Consists of:
cover cast,
O-Ring 120.2x3.53 HNBR.
22
71323035
Cover assembly
Usage:
Promass/Prosonic Flow 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing cast, Ex.
Consists of:
cover cast,
O-Ring 120.2x3.53 FVMQ, -50oC/-58oF.
74
71323036
Cover assembly
Usage:
Promag/Promass/Prosonic Flow/t-mass 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing Alu/cast, Ex.
Consists of:
10x O-Ring 120.2x3.53 HNBR.
74
71323037
Cover assembly
Usage:
Promass/Prosonic Flow/t-mass 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing Alu/cast, Ex.
Consists of:
O-Ring 120.2x3.53 FVMQ, -50oC/-58oF.
23
71323038
Housing cover assembly
Usage:
Promag 10,
Promag/Promass/Prosonic Flow 500,
wall mount transmitter Alu,
connection compartment.
Consists of:
cover Alu,
O-Ring 88.50x3.53 HNBR.
23
71323039
Cover assembly
Usage:
Promag/Promass/Prosonic Flow 500,
wall mount transmitter Alu, Ex,
connection compartment.
Consists of:
cover Alu,
O-Ring 88.50x3.53 FVMQ, -50oC/-58oF.
23
71323040
Cover assembly
Usage:
Promag/Promass/Prosonic Flow 500,
wall mount transmitter cast, Ex,
connection compartment.
Consists of:
cover cast,
O-Ring 88.50x3.53 HNBR.
23
71323041
Cover assembly
Usage:
Promag/Promass/Prosonic Flow 500,
wall mount transmitter cast, Ex,
connection compartment.
Consists of:
cover cast,
O-Ring 88.50x3.53 FVMQ, -50oC/-58oF.
75
71323042
Housing cover seal
Usage:
Promag 10,
Promag/Promass/Prosonic Flow 500,
wall mount transmitter Alu/cast,
connection compartment.
Consists of:
10x O-Ring 88.50x3.53 HNBR.
75
71323043
Cover assembly
Usage:
Promag/Promass/Prosonic Flow 500,
wall mount transmitter Alu/cast, Ex,
connection compartment.
Consists of:
O-Ring 88.50x3.53 FVMQ, -50oC/-58oF.
20
71384170
Promag400/500 housing cover
Usage:
Prosonic Flow 400, Promag 400(C),
(C) = generation index C,
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital,
transmitter housing Alu.
Consists of:
cover Alu complete included
O-Ring 196.40x3.53 HNBR,
default and -50oC/-58oF,
wire with screw lock 1.5x150.
20
71408508
Housing cover
Usage:
Prosonic Flow 400,
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital, Promag 800(C),
(C) = generation index C,
transmitter housing polycarbonate.
Consists of:
cover polycarbonate complete,
O-Ring 196.44x3.53 VMQ,
default and -50oC/-58oF,
wire with screw lock 1.5x150.
70
71278078
Housing cover seal
Usage:
Prosonic Flow 400, Promag 400(C),
(C) = generation index C,
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital,
transmitter housing Alu.
Consists of:
10x O-Ring 196.40x3.53 HNBR,
default and -50oC/-58oF.
70
71278077
Housing cover polycarbonate gasket
Usage:
Prosonic Flow 400,
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital,
Promag 400/800(C),
(C) = generation index C,
transmitter housing polycarbonate.
Consists of:
10x O-Ring 196.44x3.53 VMQ.
24
71228796
Housing cover assembly
Usage:
Promag 10/500,
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital,
Promag 400/800(C),
(C) = generation index C,
sensor connection housing.
Consists of:
cover Alu,
O-Ring 113.90x3.53 HNBR.
24
71323050
Cover assembly
Usage:
Promass/Prosonic Flow/t-mass 500digital,
sensor connection housing.
Consists of:
cover Alu,
O-Ring 113.90x3.53 FVMQ, -50oC/-58oF.
73
71323051
Housing seal assembly
Usage:
Promass/Prosonic Flow/t-mass 500digital,
sensor connection housing.
Consists of:
O-Ring 113.90x3.53 HNBR for cover,
gasket EPDM for housing/sensor.
73
71323052
Housing seal assembly
Usage:
Promass/Prosonic Flow/t-mass 500digital,
sensor connection housing.
Consists of:
O-Ring 113.90x3.53 FVMQ for cover,
-50oC/-58oF,
gasket FVMQ for housing/sensor,
-50oC/-58oF.
24
71323053
Cover assembly
Usage:
Promass 500,
Promag/Promass 500 digital,
sensor connection housing.
Consists of:
cover stainless 1.4301,
gasket EPDM for cover.
24
71323054
Cover assembly
Usage:
Promass 500,
Promass 500 digital,
sensor connection housing.
Consists of:
cover stainless 1.4301,
gasket FVMQ for cover, -50oC/-58oF.
73
71323057
Housing seal assembly
Usage:
Promass 500,
Promass 500 digital,
sensor connection housing.
Consists of:
gasket EPDM for cover,
gasket EPDM for housing/sensor.
73
71323058
Housing seal assembly
Usage:
Promass 500,
Promass 500 digital,
sensor connection housing.
Consists of:
gasket FVMQ for cover, -50oC/-58oF,
gasket FVMQ for housing/sensor,
-50oC/-58oF.
24
71185793
Stainless steel housing cover
Usage:
Promag/Promass 100,
Promag/Promass 500 digital,
sensor connection housing.
Consists of:
cover stainless 1.4301,
gasket EPDM for cover.
24
71323060
Cover assembly
Usage:
Promass 500 digital,
sensor connection housing.
Consists of:
cover stainless 1.4301,
gasket FVMQ for cover, -50oC/-58oF.
73
71185799
Housing seal
Usage:
Promass 100,
Promass 500 digital,
sensor connection housing.
Consists of:
gasket EPDM for cover,
gasket EPDM for housing/sensor.
73
71323062
Housing seal assembly
Usage:
Promass 500 digital,
sensor connection housing stainless.
Consists of:
gasket FVMQ for cover, -50oC/-58oF,
gasket FVMQ for housing/sensor,
-50oC/-58oF.
24
71323063
Cover assembly
Usage:
Promag/Promass 500,
Promag/Promass/Prosonic Flow/t-mass
500 digital, sensor connection housing.
Consists of:
cover cast,
O-Ring 120.2x3.53 HNBR.
24
71323064
Cover assembly
Usage:
Promass 500,
Promass/Prosonic Flow/t-mass 500digital,
sensor connection housing.
Consists of:
cover cast,
O-Ring 120.2x3.53 FVMQ, -50oC/-58oF.
73
71323065
Housing seal assembly
Usage:
Promass 500,
Promass/Prosonic Flow/t-mass 500digital,
sensor connection housing.
Consists of:
O-Ring 120.2x3.53 HNBR for cover,
O-Ring 88.50x3.53HNBR for housing/sensor
73
71323066
Housing seal assembly
Usage:
Promass 500,
Promass/Prosonic Flow/t-mass 500digital,
sensor connection housing.
Consists of:
O-Ring 120.2x3.53 FVMQ for cover,
-50oC/-58oF,
O-Ring 88.50x3.53 FVMQ for hous./sensor,
-50oC/-58oF.
71
71323071
Interface seal assembly
Usage:
Promass/Prosonic Flow/t-mass/
Teqwave MW 300,
Promass/Prosonic Flow 500,
transmitter housing/sensor or
transmitter housing/wall mount.
Consists of:
5x O-Ring 88.50x3.53 HNBR for
interface.
71
71323072
Interface seal assembly
Usage:
Promass/Prosonic Flow/t-mass 300,
Promass/Prosonic Flow 500,
transmitter housing/sensor or
transmitter housing/wall mount.
Consists of:
O-Ring 88.50x3.53 FVMQ for
interface, -50oC/-58oF.
11
71323081
Protective cover assembly
Usage:
transmitter housing Alu/cast,
connection compartment.
Option A =
HART, PROFIBUS PA, PROFIBUS DP,
Modbus RS485, FOUNDATION Fieldbus.
Consists of:
Connection compartment protective cover,
display carrier, 2x screw M4x10.
11
71323082
Protective cover assembly
Usage:
transmitter housing Alu/cast,
connection compartment.
Option B =
EtherNet, PROFINET.
Consists of:
Connection compartment protective cover,
display carrier, 2x screw M4x10.
13
71276494
Clamp fastening, screw
Usage: Promass 100, Promag 100,
Prosonic Flow E 100/E Heat,
CNGmass, LPGmass, LNGmass,
Promag/Promass 500, Promag 10,
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital,
Promag 400/800(C),
(C) = generation index C,
sensor connection housing.
Consists of:
cover clamp, screw M4x16.
71450719
Adapter M12, RJ45, L= 80mm (suitable for t-mass F 300/50
Usage:
Proline 300/500.
71450719
Adapter M12, RJ45, L= 80mm (suitable for t-mass F 300/50
Usage:
Proline 300/500.
71450719
Adapter M12, RJ45, L= 80mm (suitable for t-mass F 300/50
Usage:
Proline 300/500.
71450719
Adapter M12, RJ45, L= 80mm (suitable for t-mass F 300/50
Usage:
Proline 300/500.
71450719
Adapter M12, RJ45, L= 80mm (suitable for t-mass F 300/50
Usage:
Proline 300/500.
71450719
Adapter M12, RJ45, L= 80mm (suitable for t-mass F 300/50
Usage:
Proline 300/500.
71450719
Adapter M12, RJ45, L= 80mm (suitable for t-mass F 300/50
Usage:
Proline 300/500.
71450719
Adapter M12, RJ45, L= 80mm (suitable for t-mass F 300/50
Usage:
Proline 300/500.
82
71228792
Display protective cover
Usage:
Prosonic Flow 400, Promag 400(C),
(C) = generation index C,
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital,
transmitter housing Alu.
Consists of:
display protection 1.4301,
installation material.
87
71343504
Protective housing assembly
Usage:
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 400/800/500 digital,
transmitter housing.
Consists of:
weather protection cover 4404.
87
71343505
Protective housing assembly
Usage:
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 300,
Promag/Promass/Prosonic Flow 500,
transmitter housing.
Consists of:
weather protection cover 4404,
installation material.
71346427
Pipe mounting assembly
For Product:
Promag 500 digital
Promass 500 digital
t-mass 500 digital
Prosonic Flow 500 digital
Teqwave MW 500 digital
Prosonic Flow 400
71346428
Pipe mounting assembly
71351317
Wireless receiver for extended distance
Consists of:
Connection cable in the transmitter,
Ex cable entry for antenna,
1.5m cable,
antenna,
angle with union nut.
71392563
Coriolis mass flowmeter sensor bracket
Usage:
Promass A, 8A2B**, 8A3C**, 8A5C**.
Consists of:
1x sensor holder 1.4404
3x holder bracket 1.4404
2x screw M8x50 INOX A4
2x spring washer M8 INOX A4.
8X5BXX-
Transmitter mass flowmeter 500, 8X5BXX
With an integrated web server.
AA
BB
BD
BJ
BL
BN
BS
C2
C4
C6
CD
CN
CS
CZ
GB
GD
GJ
GL
GN
GR
GS
JD
JJ
KB
KD
MB
MD
MJ
ML
MN
MS
NB
ND
NJ
NL
NN
NS
UB
UD
UJ
UL
UN
UR
US
9
D
E
I
99
BA
CA
CC
GA
HA
LA
MA
NA
RA
RB
RC
SA
TA
9
A
B
C
D
E
F
G
H
I
J
9
A
B
C
D
E
F
G
H
I
J
9
A
B
C
D
E
G
H
I
J
9
F
G
9
A
B
9
A
D
L
9
A
B
E
F
J
L
3
4
5
6
9
A
B
C
D
L
M
N
P
R
S
T
U
V
AA
00
AB
00
99
BB
BF
HA
HB
HC
HD
SA
A1
A2
AA
AB
AC
AD
AE
AF
AG
AH
AI
AJ
AK
AL
AM
AQ
AR
AT
CM
E9
EA
EB
ED
EL
I7
I9
JP
K9
L9
LA
N9
NB
P7
P8
P9
PB
PV
58
60
61
64
65
66
67
68
70
71
72
73
74
75
76
77
78
Z1
Z2
DK8013-
Promass 500, sensor cable
Connection cable (analog and digital)
between sensor connection housing
and transmitter for remote versions
of Proline 500.
AA
BB
BD
BJ
BL
BN
BS
C2
C4
C6
CD
CN
CS
CZ
GB
GD
GJ
GL
GN
GR
GS
JD
JJ
KB
KD
MB
MD
MJ
ML
MN
MS
NB
ND
NJ
NL
NN
NS
UB
UD
UJ
UL
UN
UR
US
AA
A
B
9
A
B
C
L
1
2
3
9
B
E
F
J
L
JP
K9
DK8003-
Mass sensor, heat jacket, DK8003
Heating medium (e.g. water, steam)
01
02
04
AB
S
RB
RC
RD
RE
RF
RG
RH
00
A1
JB
JC
XPRFID-
Spare RFID TAG
Consists of:
RFID TAG, fixing wire, crimp sleeve.
AA
BA
CA
IA
KA
MA
NA
UA
UR
1