CLD134 Spare Parts Selection Guide and Order Number List

The CLD134 series transmitters are widely used in the field of conductivity measurement, and their spare parts are numerous. This article compiles complete spare part order numbers, specification descriptions, and selection recommendations for quick reference by engineering technicians and procurement personnel.

CLD134 Spare Parts Overview

Sensor Spare Parts

The sensor is the core measurement component of the CLD134. Depending on the model version, the corresponding spare part must be selected.

Sensor Kits

  • 71020487: Kit CLD134, version MV5, spare sensor
  • 71020488: Sensor
  • 71020489: Sensor
  • 71020490: Sensor
  • 71020491: Sensor
  • 71020492: Sensor

Main Module and Output Module

The main module determines the output type and communication protocol of the transmitter. The fieldbus requirements must be confirmed during selection.

Main Module Selection Table

Order NumberDescriptionOutput/Protocol
71025965Kit CLD134 Main Module1 output
71025968Output Module
71025969Kit CLD134 Main Module1 output+HART
71025970Kit CLD134 Main Module2 outputs+HART
71025971Kit CLD134 Main ModuleProfibus PA
71025972Kit CLD134 Main ModuleProfibus DP

Central Processing Unit and Terminal Module

  • 71134734: CLD134 Central Processing Unit, content: 1x Central module Profibus DP, module name: LSCP-DP, qualified from hardware version 2.10
  • 71134735: CLD134 Terminal Module, content: 1x Terminal module Profibus DP, module name: LSKB, suitable for central module from hardware version 2.10

Transmitter Board and Power Supply

The transmitter board and power supply module provide signal processing and power supply for the transmitter, and must be selected according to the supply voltage.

  • 71161133: Transmitter Board
  • 51501585: Kit CLD132/4 Power Supply, 100/115/230VAC
  • 51501586: Kit CLD132/4 Power Supply, 24V AC/DC

Housing and Mechanical Components

Housing components include the base, panel, module box, etc., and are available in separate and compact mounting versions.

Housing Component List

Order NumberDescriptionRemarks
51501574CLD132/134 Separate Version Housing BaseKit CLD132/4 lower casing seperate vers.
51501576CLD132/134 Compact Version Housing BaseKit CLD132/4 lower casing compact vers.
50062121Transmitter Protection Coverround post installation
51501577CLD132/134 Compact Version Housing PanelKit CLD132/4 housing cover complete
51501584Kit CLD132/4 Module Box
51502280Kit CLD132/4 Module BoxFor PA/DP

Wiring and Cable Components

  • 51501587: CLD132/4 Terminal Block, 5+8+13 pol.
  • 51502281: Kit CLD132/4 Junction Box, PA/DP
  • 51501588: CLD132/4 Flat Cable, 20 poles
  • 51502282: CLD132/4 M20 Cable Entry and Breather, with Goretex filter
  • 51502283: CLD132/4 Coil Cable Entry and Breather, with Goretex

Sealing and Protection

  • 51501596: CLD132/4 Seals and Small Parts
  • 51502382: CLD132/4 Relay Wiring Protection Cover

Function Expansion and Calibration Solutions

Function expansion upgrade packages can improve transmitter performance, and calibration solutions are used for calibrating conductivity measurement systems.

Function Expansion

  • 51501643: CLD132/134 Function Expansion Upgrade Package

Calibration Solution Selection Table

Order NumberCalibration ValueSpecification
5008190274.0 uS/cm500 ml, reference temperature 25°C, NIST SRM traceable, with temperature table, compliant with ISO standards
50081903500 ml, reference temperature 25°C, NIST SRM traceable, with temperature table, compliant with ISO standards
500819041.406 mS/cm500 ml, reference temperature 25°C, NIST SRM traceable, with temperature table, compliant with ISO standards
50081905500 ml, reference temperature 25°C, NIST SRM traceable, with temperature table, compliant with ISO standards
50081906500 ml, reference temperature 25°C, NIST SRM traceable, with temperature table, compliant with ISO standards

Selection Notes

  • Confirm the transmitter model and hardware version, e.g., Profibus modules require hardware version 2.10 or above.
  • Select the power module according to the supply voltage: 100/115/230VAC or 24V AC/DC.
  • Calibration solutions should be selected with appropriate concentration according to the measuring range, and attention should be paid to NIST SRM traceability.
  • Housing components are available in compact and separate versions; the installation method must match.

The above spare part information is for reference only. For actual selection, please refer to the latest official catalog.