CLM223 Transmitter Spare Parts List Overview

This article provides a complete spare parts list for the CLM223 transmitter, suitable for upgrading and maintaining the LIQUISYS-M basic version. Spare parts include relay modules, power supply modules, housing accessories, mainboards, and conductive/inductive modules. All order numbers and specifications are based on original manufacturer data for reference by engineering and procurement personnel.

Relay Modules and Output Modules

Relay modules are used to expand the digital output capability of the LIQUISYS-M and support floating changeover contacts. The following are commonly used models and specifications.

Order NumberSpecificationDescriptionPosition Number
51511446Relay moduleUpgrade LIQUISYS-M basic version, add 2 floating changeover contacts290
51500320Relay output moduleUpgrade LIQUISYS-M basic version, add 2 floating changeover contacts-
51500321Relay output circuit boardUpgrade LIQUISYS-M basic version, add 4 floating changeover contacts300
71129943Relay moduleUpgrade LIQUISYS-M basic functions, add 4 dry changeover contacts, electronic components with protective coating300
51511447Relay moduleUpgrade LIQUISYS-M basic version, add 2 contacts290
51504304Relay output moduleUpgrade LIQUISYS-M basic version, add 2 contacts and 4-20mA current input300
51504305Relay output moduleUpgrade LIQUISYS-M basic version, add 4 contacts and 4-20mA current input300

Power Supply Modules

Power supply modules provide stable power to the transmitter and are available in AC and DC types. Please select according to on-site power conditions.

  • 51500317: CXM2X3 AC power supply kit, position number 15
  • 71129939: CXM2X3 AC power supply, 100/115/230 V AC, electronic components with protective coating, position number 15
  • 51500318: CXM2X3 DC power supply kit, position number 20

Housing and Mechanical Accessories

Housing accessories are used to maintain or replace mechanical parts of the transmitter, ensuring protection rating and installation compatibility.

  • 51501075: CXM223 housing accessory kit, position number 330
  • 51501076: CXM223 mechanical housing parts kit
  • 51502124: CXM223 side panel kit, position number 310
  • 51502513: CXM223 Profibus DP bottom cover kit, position number 340
  • 51501086: CXM223 grounding terminal block kit, position number 345
  • 51501078: CXM223 terminal block kit, position number 430
  • 71071440: CxM223 front membrane + 6 key risers kit, position number 335
  • 50047795: Housing mounting bracket

CLM2x3 Mainboard and Conductive Modules

The CLM2x3 series modules are the core of the transmitter, supporting conductive and inductive measurement. The following are conductive module models.

Order NumberSpecificationDescriptionPosition Number
51501210CLM2x3 mainboardKIT CLM2x3 central module I1 conductive40
51501213CLM2X3 conductive moduleKIT CLM2X3 conductive module I1 HART60
51501212CLM2X3 conductive moduleKIT CLM2X3 conductive module I250
51501214CLM2X3 conductive moduleKIT CLM2X3 conductive module I2 HART70
51501215CLM2X3 main moduleKIT CLM2X3 central module Profibus PA conductive80
51502502Kit CLM2X3 main moduleKit CLM2X3 central module Profibus DP conductive90
71134726Kit CLM2x3 main moduleCentral module Profibus DP, hardware version 2.1x, module name LSCP-DP, qualified from H/W 2.1090
71134732Relay moduleProfibus DP relay module, 2 relays, 1 current input DP connection, qualified from H/W 2.10290

CLM2x3 Inductive Modules

Inductive modules are suitable for conductivity measurement without direct electrode contact with the medium. The following are commonly used models.

  • 51501216: CLM2x3 inductive module I1, position number 40
  • 51501219: CLM2x3 inductive module I1 HART, position number 60
  • 51501218: CLM2x3 inductive module I2, position number 50
  • 51501220: CLM2x3 inductive module I2 HART, position number 70
  • 51501221: CLM2X3 main module, Profibus PA inductive, position number 80
  • 51502501: Kit CLM2X3 main module, Profibus DP inductive, position number 90
  • 71134727: Kit CLM2x3 main module, central module Profibus DP inductive, hardware version 2.1x, module name LSCP-DP, qualified from H/W 2.10, position number 90

CLM223 Terminal Blocks

Terminal blocks are used for field wiring and support different bus protocols. Please select according to communication requirements.

  • 51501203: CLM223 terminal block kit, position number 420
  • 51502126: KIT CLM223 terminal block, Profibus PA, position number 420
  • 51502493: Kit CLM223 terminal block, Profibus DP, position number 420

Software Upgrade Packages

Software upgrade packages can extend transmitter functions and require the instrument serial number. Some upgrades require additional hardware support.

  • 51500385: "Extended software" upgrade package, upgrades LIQUISYS-M basic version to S version (plus-package), supports parameters pH, conductivity, temperature, chlorine, oxygen (WX to WS), requires instrument serial number.
  • 51500963: "Cleaning function" upgrade package, upgrades LIQUISYS-M basic version, adds cleaning function (Chemoclean), requires instrument serial number. If the 4-relay board is not installed, order 51500321 separately.

Other Spare Parts

  • 71161133: Transmitter board, position number 240

The above spare parts list covers the main maintenance and upgrade components of the CLM223 transmitter. When purchasing, please verify the order numbers and specifications to ensure compatibility with the existing system. For more information, please refer to the original manufacturer's technical documentation.