CCS142D Residual Chlorine Sensor Spare Parts Overview
CCS142D is a commonly used sensor model in industrial residual chlorine measurement, and timely replacement of its spare parts and consumables is crucial to ensuring measurement accuracy. This article compiles the complete spare part order numbers, specifications, and supporting accessories for this sensor, facilitating quick reference for engineering personnel and procurement.
Core Spare Parts List
| No. | Order Number | Specification Description |
|---|---|---|
| 1 | 71268479 | Kit CCSx4x/142D: Measuring chamber |
| 2 | 71268482 | CCSx4x/142D spare parts: Seals x2 |
| A | 50005255 | Membrane replacement 2 pcs., ready made for CCS 140/141/240/241 |
| A | 50005256 | Electrolyte 50 ml, for CCS 140/141 |
| A | 71076921 | Maintenance kit CCS14x includes: electrolyte 50ml, 2 membrane caps, polishing foil (2 qualities) |
Supporting Accessories and Tools
Junction Box and Cable
- 51500832 Junction box RM: Used to extend cables for Memosens/CUS31/41, protection class IP 65, with 2x Pg 13.5 connections.
- CYK10- Digital electrode cable: Suitable for digital sensors with inductive Memosens plug, operating temperature range -20...135°C.
Calibration and Verification Tools
- 71257946 Handheld DPD colorimetric calibrator PF-3: Used for colorimetric measurement of free chlorine and total chlorine, range 0.05 - 6mg/l, suitable for disinfection, drinking water, and process water. Complies with ISO 7393 standard, protection class IP67, includes cuvettes, DPD reagents, and carrying case.
- COY8- Zero-point gel: Used for zero-point verification, calibration, and adjustment of oxygen and disinfection sensors, suitable for amperometric and optical sensors, diameter 12, 25, and 40mm, can be used in laboratory or on-site.
Selection and Ordering Notes
- Confirm the sensor model is CCS140/141/240/241 or CCS142D to match the corresponding spare parts.
- Choose individual spare parts or maintenance kits based on maintenance needs; maintenance kits are more economical and convenient.
- Cables and junction boxes should be selected according to on-site installation distance and protection requirements.
- Calibrators and zero-point gel are used for regular calibration; it is recommended to establish a calibration cycle based on operating conditions.
Proper selection of spare parts can extend sensor life and ensure stable and reliable residual chlorine measurement. For complete technical parameters, please refer to the original manufacturer's manual or contact the supplier.