CCS141 Spare Parts List Overview

CCS141 is a commonly used analyzer model in industrial water quality analysis, and its spare parts system covers the measuring chamber, seals, membranes, electrolyte, maintenance kit, and matching cables, etc. Correct selection of spare parts is key to ensuring the long-term stable operation of the analyzer.

Based on the original manufacturer's spare parts list, this article organizes order numbers, specifications, and applicable scenarios by functional module, making it convenient for engineering technicians and procurement personnel to quickly consult.

Core Measuring Components

Measuring Chamber and Seals

The measuring chamber and seals are the core wetted parts of the CCS141 analyzer. They come into direct contact with the sample and require regular inspection and replacement.

No. Order Number Specification Description
1 71268479 Kit CCSx4x/142D: Measuring chamber
2 71268482 CCSx4x/142D spare parts: Seals x2

The measuring chamber is recommended to be replaced according to the manufacturer's recommended cycle, while seals should be inspected during each disassembly or when leakage is found.

Membranes and Electrolyte

Membranes and electrolyte directly affect the measurement accuracy and response speed of the sensor and are consumable spare parts.

  • 50005255: Membrane replacement parts, 2 pcs., ready made for CCS 140/141/240/241
  • 50005256: Electrolyte, 50 ml, for CCS 140/141

After membrane replacement, it must be used together with electrolyte to ensure sufficient electrolyte inside the sensor without bubbles.

Maintenance and Installation Accessories

Maintenance Kit CCS14x

The maintenance kit is a convenient choice for daily care, containing a variety of commonly used consumables, suitable for regular maintenance plans.

  • Electrolyte 50ml / 1.69 fl.oz.
  • 2 membrane caps
  • Polishing foil (2 qualities)

Order number: 71076921. The maintenance kit reduces the hassle of separate procurement and is recommended as regular stock.

Junction Box and Measuring Cable

The junction box and measuring cable are used for signal transmission and system expansion. Attention should be paid to the protection rating in the installation environment.

Order Number Name Specifications and Use
50005181 Junction box VBC Used to extend CMK measuring cable, protection rating IP65
50085333 Measuring cable Suitable for pH/Redox electrodes or 2-electrode conductivity cells/2-electrode current cells, with temperature sensor; priced per meter, minimum length 5 m

Measuring cable order requires specifying the required length and confirming compatibility with the sensor type.

Calibration and Verification Tools

Handheld DPD Colorimetric Calibration Instrument PF-3

PF-3 is used for colorimetric measurement of free chlorine and total chlorine in disinfection loops and is an ideal tool for calibration and verification.

  • Measuring range: 0.05 - 6 mg/l
  • Application areas: Disinfection, drinking water, and process water
  • Protection rating: IP67
  • Complies with standard: ISO 7393
  • Configuration: Cuvette, DPD reagent, plastic case, free chlorine and total chlorine test kit

Order number: 71257946. This instrument is suitable for on-site quick calibration and verification.

Zero-Point Gel COY8

COY8 zero-point gel is used for zero-point verification, calibration, and adjustment of oxygen and disinfection sensors.

  • Applicable sensors: Amperometric and optical sensors
  • Diameter specifications: 12, 25, and 40 mm
  • Application scenarios: Laboratory and on-site

Order number prefix: COY8-. Using zero-point gel can effectively confirm the sensor zero-point drift condition.

Selection and Procurement Recommendations

To ensure the stable operation of the CCS141 analyzer, it is recommended to manage spare parts according to the following steps:

  1. Confirm spare part compatibility according to the analyzer model, e.g., membranes are common to the CCS 140/141/240/241 series.
  2. Regularly inspect the condition of the measuring chamber, seals, and membranes, and replace them according to the manufacturer's recommended cycle.
  3. Keep maintenance kits (71076921) and electrolyte (50005256) in stock to reduce downtime.
  4. Order measuring cables according to actual length requirements, noting that the minimum order quantity is 5 meters.
  5. Use calibration instrument PF-3 and zero-point gel COY8 for periodic calibration to ensure accurate measurement data.

Through standardized spare parts management, the reliability and service life of the water quality analysis system can be significantly improved.