CCS58D Spare Parts List Overview

CCS58D is a Memosens series digital sensor widely used in disinfection, drinking water, and process water monitoring. To ensure its long-term stable operation, correct selection of spare parts is crucial. This article compiles a list of commonly used spare parts for the CCS58D, including adapter kits, calibration instruments, maintenance components, etc., for reference by engineering technicians and procurement personnel.

CCS58D Sensor

Adapter Kits

Adapter kits are used to connect CCS5x and CCS5xD sensors to different types of holders or flow cells. The following are commonly used adapter kits and their order numbers.

Order NumberSpecification
71372025CCA250 adapter kit CCS5x + CCS5xD
71372026CYA112 adapter kit CCS5x + CCS5xD
71372027CCA151 adapter kit CCS5x + CCS5xD, including fixing ring, thrust ring, sealing ring
71554885Kit adapter CCS5x(D/E) for CYA27-xxxB*

CCA151 Adapter Kit Details

The CCA151 adapter kit includes a fixing ring, thrust ring, and sealing ring, ensuring secure sensor installation and reliable sealing. Suitable for applications requiring high sealing performance.

Calibration and Maintenance Tools

Regular calibration and maintenance are key to ensuring measurement accuracy. The following tools are used for calibration and verification of disinfection loops.

Handheld DPD Colorimetric Calibration Instrument PF-3

The PF-3 is a handheld photometer that uses the DPD colorimetric method to measure free chlorine and total chlorine, with a range of 0.05-6 mg/l and protection class IP67. Suitable for disinfection, drinking water, and process water applications, compliant with ISO 7393 standard. Delivery includes a plastic case, cuvettes, and DPD reagent kit for calibration and verification of disinfection loops.

PF-3 Handheld DPD Colorimetric Calibration Instrument

Maintenance Kit CCV05

The maintenance kit CCV05 is used for routine maintenance of Memosens CCSxxD and fixed cable sensors CCSxx, ensuring long-term stable operation of the sensor.

Zero-Point Gel COY8

The zero-point gel COY8 is used for zero-point verification, calibration, and adjustment of oxygen and disinfection sensors. Suitable for amperometric and optical sensors, diameters 12, 25, and 40 mm, can be used in the laboratory or on-site.

Selection Guide

When selecting spare parts, please confirm compatibility based on the sensor model, installation method, and application environment. It is recommended to refer to the following points:

  • Confirm the sensor model: CCS5x or CCS5xD.
  • Select the adapter kit according to the mounting bracket (e.g., CCA250, CYA112, CCA151).
  • Regular calibration: It is recommended to use the PF-3 calibration instrument for disinfection loop verification.
  • Maintenance: Use CCV05 maintenance kit and COY8 zero-point gel.

Summary

This article lists commonly used spare parts for the CCS58D sensor, including adapter kits, calibration instruments, maintenance components, and zero-point gel. Correct selection and regular maintenance can ensure measurement accuracy and sensor lifespan. For more information, please consult the manufacturer or distributor.