CCS55D Spare Parts List Overview

The CCS55D is a digital sensor in the Memosens series, widely used in disinfection, drinking water, and process water monitoring. To ensure long-term stable operation, selecting the correct spare parts is crucial. This article compiles a list of commonly used spare parts for the CCS55D, including adapter kits, calibration instruments, maintenance kits, and zero-point gel, for quick reference by engineers and procurement personnel.

Adapter Kits

Adapter kits are used to install CCS5x or CCS5xD sensors onto different models of flow-through assemblies or holders. The following are commonly used adapter kits and their order numbers.

Order NumberSpecification Description
71372025CCA250 adapter kit CCS5x + CCS5xD
71372026CYA112 adapter kit CCS5x + CCS5xD
71372027CCA151 adapter kit CCS5x + CCS5xD, includes: fixing ring, thrust ring, sealing ring
71554885Kit adapter CCS5x(D/E) for CYA27-xxxB*

Adapter Kit Selection Points

  • Confirm the sensor model is CCS5x or CCS5xD to ensure compatibility.
  • Select the corresponding flow-through assembly model (e.g., CCA250, CYA112, CCA151) based on the installation location.
  • If a complete sealing kit is required, prioritize 71372027, which includes the fixing ring, thrust ring, and sealing ring.

Handheld DPD Colorimetric Calibration Instrument PF-3

The PF-3 is a handheld photometer used for colorimetric measurement of free chlorine and total chlorine in disinfection loops, compliant with ISO 7393. This instrument is suitable for on-site calibration and verification, has an IP67 protection rating, and is equipped with a cuvette and DPD reagents for easy portability.

Technical Parameters

ItemParameter
Measuring range0.05 - 6 mg/l
Measured parametersFree chlorine, total chlorine
Application areasDisinfection, drinking water, process water
Protection ratingIP67
StandardISO 7393
Order number71257946

This calibration instrument is commonly used for calibration and verification of disinfection loops to ensure accurate sensor measurement.

Maintenance Kits and Zero-Point Gel

Regular maintenance is key to ensuring sensor performance. The CCV05 maintenance kit and COY8 zero-point gel are commonly used spare parts for CCS55D sensor maintenance.

CCV05 Maintenance Kit

  • Order number: CCV05-
  • Applicable sensors: Memosens CCSxxD and fixed cable sensors CCSxx
  • Purpose: Daily maintenance, cleaning, and replacement of wear parts

COY8 Zero-Point Gel

  • Order number: COY8-
  • Purpose: Zero-point verification, calibration, and adjustment of oxygen and disinfection sensors
  • Applicable sensor types: Amperometric and optical sensors
  • Applicable diameters: 12 mm, 25 mm, 40 mm
  • Application scenarios: Laboratory, on-site

Using zero-point gel allows quick verification of the sensor zero point to ensure measurement accuracy. Maintenance kits help extend sensor service life.

Spare Parts Selection and Procurement Recommendations

When purchasing spare parts, please select the corresponding order number based on the sensor model, installation method, and maintenance requirements. It is recommended to regularly check spare parts inventory to avoid downtime due to missing critical spare parts. For a complete spare parts list, refer to the above tables or contact the supplier for the latest information.