CCM223 Spare Parts List Overview

CCM223 is the core model of the LIQUISYS-M series transmitters, widely used in industrial water treatment and process analysis. This article provides a complete spare parts list, including relay modules, power supply kits, main modules, terminal blocks, and upgrade packages. All spare parts are classified by order number, specification, and function for quick reference by engineering technicians and procurement personnel.

Relay Output Modules and Circuit Boards

Relay modules are used to expand the digital output capability of the LIQUISYS-M basic version, supporting floating changeover contacts. When selecting, pay attention to the number of contacts and the current input type.

Order NumberSpecificationFunction DescriptionRemarks
51500320Relay output moduleUpgrades LIQUISYS-M basic version via 2 floating changeover contacts
51511446Relay moduleUpgrades LIQUISYS-M basic version via 2 floating changeover contacts
51500321Relay output circuit boardUpgrades LIQUISYS-M basic version via 4 floating changeover contacts
51511447Relay module
51504304Relay output moduleLIQUISYS-M basic version upgraded to 2 contacts, current input 4-20mA
51504305Relay output moduleLIQUISYS-M basic version upgraded to 4 contacts, current input 4-20mA

Power Supply and Housing Accessories

Power supply kits provide AC or DC power to the transmitter, and housing accessories are used for mechanical protection and installation. The following are commonly used power supply and housing components.

  • 51500317: CXM2X3 AC power supply, kit CXM2X3 power supply AC
  • 51500318: CXM2X3 DC power supply, kit CxM2x3 power supply DC
  • 51501075: CXM223 housing accessory, kit CXM223 housing assembly
  • 51501076: CXM223 mechanical housing parts, kit CXM223 mechanical housing parts
  • 51502124: CXM223 side panel, kit CXM223 side wall
  • 51502513: CXM223 Profibus DP bottom cover, kit CXM223 end frame Profibus DP
  • 51501078: CXM223 terminal block, KIT CXM223 terminal block

Transmitter and Main Module Kits

The main module kit is the core of the CCM2x3 system, responsible for signal processing and communication. Select the corresponding model based on measurement parameters and communication protocol.

Order NumberSpecificationDescription
51502466KIT MKC1 MEK transmitterKIT MKC1 MEK transmitter Cl wo pH non Ex
51502465Kit MKC1 MEK transmitterMKC1 MEK transmitter Cl+pH non Ex
51502467Kit CCM2x3 main moduleKit CCM2x3 central module I1
51502497Kit CCM2x3 main moduleKit CCM2x3 central module I1 HART
51502468Kit CCM2x3 main moduleKit CCM2x3 Central module I2
51502496Kit CCM2x3 main moduleKit CCM2x3 central module I2 HART
51502495Kit CCM2X3 main moduleKit CCM2X3 central module Profibus PA
51502498Kit CCM2X3 main moduleKit CCM2X3 central module Profibus DP
71134731Kit CCM2x3: Central processing unit
71134732Relay moduleContents: 1 relay module Profibus DP, 2 relays, 1 current input DP connection, compliant with H/W 2.10 standard

Terminal Block Kits

Terminal block kits are used to connect field signals to the transmitter, supporting mA, HART, and Profibus protocols. Please select the corresponding order number according to the communication method.

  • 51502463: Kit CCM223 terminal block, CCM223 terminal block kit, mA + HART
  • 51502490: Kit CCM223 terminal block, kit CCM223 terminal block, Profibus DP
  • 51502464: Kit CCM223 terminal block, kit CCM223 terminal block, Profibus PA

Upgrade Packages and Software

Upgrade packages are used to expand the functions of the LIQUISYS-M basic version, such as adding measurement parameters, cleaning functions, or communication protocols. Some upgrades require the instrument serial number.

  1. 51500385: "Extended software" upgrade package. Upgrades LIQUISYS-M basic version to S version (plus-package), supporting pH, conductivity, temperature, chlorine, oxygen, and other parameters. Requires instrument serial number.
  2. 51500963: "Cleaning function" upgrade package. Upgrades LIQUISYS-M basic version via cleaning function (Chemoclean). Requires instrument serial number. If not yet installed, a 4-relay board (51500321) must be ordered separately.
  3. 51502460: "pH measurement" upgrade package. Used to convert basic version Liquisys S CCM2X3-EK to pH or ORP measurement, adding additional functions. Instrument serial number must be included in the order.
  4. 51503526: "pH measurement" upgrade package. Used to convert Liquisys S CCM2X3-ES to pH or ORP measurement, adding additional functions.

Other Accessories

Other accessories include front foil, key lifters, and mounting brackets for equipment maintenance and installation.

  • 71071440: Kit CxM223: front foil + 6 key lifters
  • 50047795: Housing mounting bracket

Selection and Ordering Notes

When ordering spare parts, be sure to verify the order number and equipment model. For upgrade packages, the instrument serial number must be provided to ensure compatibility. If unsure about the selection, it is recommended to consult the supplier's technical support.

  • Confirm the current version of the equipment (basic version or S version)
  • Confirm the required communication protocol (HART, Profibus PA/DP)
  • Confirm the number of relay contacts and current input type
  • Upgrade packages require the serial number