CCM253/LIQUISYS-M Spare Parts and Upgrade Kits Overview

The CCM253 (LIQUISYS-M series) transmitter is widely used in wastewater treatment, chemical, and process analysis fields. To ensure long-term stable operation of the instrument, reasonable selection of spare parts and upgrade kits is crucial.

This article organizes common spare part ordering numbers, specifications, and selection key points by functional module, facilitating quick reference for engineering technicians and procurement.

CCM253 Transmitter Appearance

Relay Output Modules and Circuit Boards

Relay modules are used to expand the transmitter's digital output capability, commonly with 2 or 4 floating changeover contacts, and some models support 4-20mA current input.

  • 51500320: Relay output module, 2 floating changeover contacts, for upgrading LIQUISYS-M basic version.
  • 51511446: Relay module, 2 floating changeover contacts, for upgrading LIQUISYS-M basic version.
  • 51500321: Relay output circuit board, 4 floating changeover contacts, for upgrading LIQUISYS-M basic version.
  • 51511447: Relay module, suitable for specific configuration expansion.
  • 51504304: Relay output module, 2 contacts, current input 4-20mA, for upgrading LIQUISYS-M basic version.
  • 51504305: Relay output module, 4 contacts, current input 4-20mA, for upgrading LIQUISYS-M basic version.

When selecting, confirm the number of contacts, whether current input is included, and the installation position to avoid conflicts with existing modules.

CCM2x3 Central Module and Main Module Kits

The central module is the core processing unit of the transmitter, and different communication protocols require corresponding kits. Below are the ordering numbers and specifications of main module kits.

Ordering NumberSpecificationDescription
51502467Kit CCM2x3 Central Module I1Basic central module
51502497Kit CCM2x3 Central Module I1 HARTSupports HART communication
51502468Kit CCM2x3 Central Module I2Enhanced central module
51502496Kit CCM2x3 Central Module I2 HARTSupports HART communication
51502495Kit CCM2X3 Central Module Profibus PAProfibus PA protocol
51502498Kit CCM2X3 Central Module Profibus DPProfibus DP protocol
71134731Kit CCM2x3 Central ProcessorCentral processor unit

When selecting the central module, determine the model based on the fieldbus type (HART, Profibus PA/DP) and I/O requirements.

CCM2x3 Central Module

Power Supply and Transmitter Kits

Power supply kits provide stable power to the transmitter, while transmitter kits are used to connect pH, chlorine, and other sensors.

  • 51500317: CXM2X3 AC power supply kit, suitable for AC power supply applications.
  • 51500318: CXM2X3 DC power supply kit, suitable for DC power supply applications.
  • 51502466: KIT MKC1 MEK transmitter, Cl without pH, non-explosion-proof.
  • 51502465: Kit MKC1 MEK transmitter, Cl+pH, non-explosion-proof.
  • 71134732: Relay module, including 1 Profibus DP relay module, 2 relays, 1 current input DP connection, compliant with H/W 2.10 standard.

Power supply selection must match the on-site power supply system, and transmitter kits should be selected based on measurement parameters (such as residual chlorine, pH).

CXM253 Housing and Installation Accessories

Housing and installation accessories are used for mechanical installation and protection of the transmitter, ensuring reliable on-site operation.

  • 51501068: KIT CXM253 instrument panel, kit CXM253 housing cover.
  • 71071446: Kit CxM253 front foil + 6 key lifters.
  • 51501073: CXM253 internal mounting parts, KIT CXM253 internal housing parts.
  • 51502184: Transmitter connection head.
  • 51501072: CXM253 mounting base plate, kit CXM253 housing bottom.
  • 51501069: Mounting hinge, kit hinge.
  • 51501079: CXM223 terminal block power supply, KIT CXM253 terminal block power supply.
  • 51501074: CXM253 flat cable, KIT CXM253 ribbon cable.
  • 50086842: LIQUISYS transmitter column mounting part, used to install the field transmitter on horizontal or vertical pipes (maximum diameter 60mm), material is stainless steel V2A.

Installation accessory selection requires confirmation of pipe diameter, material, and protection class requirements.

CXM253 Installation Accessories

Software Upgrade Packages and Function Expansion

Upgrade packages can expand the functions of the LIQUISYS-M basic version, such as adding measurement parameters, cleaning functions, etc. Upgrades usually require the instrument serial number.

  1. 51500385: Extended software upgrade package, upgrades LIQUISYS-M basic version to S version (plus-package), supports pH, conductivity, temperature, chlorine, oxygen, and other parameters (WX to WS). Instrument serial number required.
  2. 51500963: Cleaning function upgrade package, adds Chemoclean cleaning function to LIQUISYS-M basic version. Instrument serial number required. If the 4-relay board is not installed, order 51500321 separately.
  3. 51502460: pH measurement upgrade package, used to upgrade the basic version Liquisys S CCM2X3-EK to pH or ORP measurement and add additional functions. Order must include instrument serial number.
  4. 51503526: pH measurement upgrade package, used to upgrade Liquisys S CCM2X3-ES to pH or ORP measurement and add additional functions.

Before upgrading, confirm the current instrument version and hardware configuration, and install the required relay board first if necessary.

Selection and Ordering Precautions

To ensure correct matching of spare parts, please pay attention to the following points when ordering:

  • Confirm the transmitter model and version (e.g., LIQUISYS-M basic version, S version).
  • Verify the communication protocol (HART, Profibus PA/DP) and central module model.
  • Check the number of relay contacts and whether current input is required.
  • Software upgrade packages require the instrument serial number.
  • Installation accessories must match pipe size and material.

It is recommended to keep a complete ordering number list for future maintenance and procurement.