CCS241 Spare Parts Overview

CCS241 is a key model in industrial analyzers, and its spare parts management directly affects measurement accuracy and equipment lifespan. Based on the official spare parts list, this article compiles commonly used spare parts and their recommendation levels for quick reference by engineers and procurement personnel.

Spare parts are categorized by function into measurement chamber, seals, electrolyte, maintenance kit, junction box, measuring cable, calibration tools, etc. Each item is marked with order number, description, recommendation level (S/M/A), and location group.

Core Spare Parts List

The following table lists the main spare parts for CCS241, including order number, description, recommendation level, location, and group. In the recommendation level, S means strongly recommended, M means recommended, and A means optional.

Order Number Description Recommended Location Group
71268479 Kit CCSx4x/142D: Measurement chamber S 1 Housing/Housing accessories
71268482 CCSx4x/142D spare part: Seal x2 S 2 Seals
50064294 Electrolyte 50 ml, for CCS 240/241 M Unclassified
71076922 Maintenance kit CCS24x Content: Electrolyte 50ml / 1.69 fl.oz.; 2 membrane caps; polish foil (2 qualities) M A Unclassified
50005181 Junction box VBC For extension of CMK measuring cable Protection class: IP65 A Unclassified
50085333 Measuring cable For pH-/Redox electrodes or 2-electrode conductivity cells/2-electrode amperometric cells with temperature sensor. Price per meter (minimum length 5 m). A Unclassified
71257946 Handheld DPD colorimetric calibration instrument PF-3 colorimetric measurement of free and total chlorine 0.05 - 6mg/l Disinfection, drinking and process water hand held photometer, IP67-graded, with cuvettes, DPD, according to ISO 7393 delivery in plastic case, test kit for free and total chlorine included hand-held photometer for calibration and verification of disinfection loops A Unclassified
COY8- Zero-point gel COY8 Zero point: Verification, calibration, adjustment at zero point of oxygen and disinfection sensors:: Amperometric and optical sensors:: 12, 25 and 40mm diameter:: Application in the lab, in the field A Unclassified

Spare Parts Selection Recommendations

Measurement Chamber and Seals

Measurement chamber (71268479) and seals (71268482) are essential spare parts with recommendation level S, located in the housing/accessories and seals groups respectively. Regular inspection and replacement are recommended to prevent leaks affecting measurement.

Electrolyte and Maintenance Kit

Electrolyte (50064294) and maintenance kit (71076922) have recommendation level M, suitable for routine maintenance. The maintenance kit includes electrolyte, membrane caps, and polishing foil, meeting multiple needs at once.

Junction Box and Measuring Cable

Junction box VBC (50005181) is used to extend the CMK measuring cable, with protection class IP65; measuring cable (50085333) is suitable for pH/redox electrodes or conductivity cells, sold per meter, minimum length 5 meters. Both have recommendation level A, to be selected as needed.

Calibration Tools

Handheld DPD colorimetric calibration instrument PF-3 (71257946) is used for colorimetric measurement of free and total chlorine, compliant with ISO 7393, suitable for disinfection, drinking water, and process water. Recommendation level A.

Zero-point gel COY8 is used for zero-point verification, calibration, and adjustment of oxygen and disinfection sensors, suitable for laboratory and field use, compatible with amperometric and optical sensors, diameters 12, 25, and 40mm. Recommendation level A.

Maintenance and Procurement Notes

  • Regularly inspect the measurement chamber and seals, and it is recommended to prioritize stocking according to recommendation level S.
  • Electrolyte and maintenance kit can be stocked appropriately based on usage frequency.
  • Calibration tools such as PF-3 and COY8 should be configured according to the calibration cycle.
  • Pay attention to the accuracy of order numbers during procurement to avoid confusion.

For the complete spare parts list or technical consultation, please contact official channels for the latest information.