CCS240 Spare Parts Overview
CCS240 is a commonly used analyzer in industrial processes, and its spare parts management is crucial for ensuring continuous operation. This article compiles a complete CCS240 spare parts list, covering key components such as measuring chamber, seals, electrolyte, and maintenance kit, and provides selection and maintenance recommendations to help engineering technicians and procurement personnel efficiently complete spare parts procurement and replacement.
Spare Parts List and Specifications
The following spare parts are classified by function, with detailed order numbers, specifications, and applicable models for quick reference.
Measuring Chamber and Seals
- Order No. 71268479: Kit CCSx4x/142D measuring chamber, suitable for CCS240 and other models.
- Order No. 71268482: CCSx4x/142D spare seals x2, used for measuring chamber sealing.
Membrane and Electrolyte
- Order No. 50005255: Membrane replacement, 2-pack, pre-formed, suitable for CCS 140/141/240/241.
- Order No. 50064294: Electrolyte, 50 ml, suitable for CCS 240/241.
Maintenance Kit
- Order No. 71076922: Maintenance kit CCS24x, includes electrolyte 50ml, 2 membrane caps, polishing foil (2 qualities).
Junction Box and Measuring Cable
- Order No. 50005181: Junction box VBC, for extending CMK measuring cable, protection class IP65.
- Order No. 50085333: Measuring cable, suitable for pH/redox electrode or 2-electrode conductivity cell/2-electrode current cell, with temperature sensor, priced per meter (minimum length 5 meters).
Calibration and Verification Tools
- Order No. 71257946: Handheld DPD colorimetric calibration instrument PF-3, for colorimetric measurement of free chlorine and total chlorine, range 0.05-6mg/l, suitable for disinfection, drinking water and process water. Handheld photometer, IP67 protection, includes cuvettes, DPD reagents, complies with ISO 7393, delivered with plastic case and test kit.
- Order No. COY8-: Zero-point gel COY8, for zero-point verification, calibration and adjustment of oxygen and disinfection sensors, suitable for amperometric and optical sensors, diameters 12, 25 and 40mm, can be used in laboratory or on-site.
Spare Parts Selection Recommendations
When selecting spare parts, consider equipment model, measurement parameters, and environmental conditions. The following are key selection points:
- Confirm that the spare part is compatible with the CCS240 model, e.g., measuring chamber Kit CCSx4x/142D is suitable for CCS240.
- Select the maintenance kit according to the maintenance cycle to obtain common consumables at once.
- The length of the measuring cable should be determined according to the on-site distance, with a minimum of 5 meters.
- Calibration tools should be selected according to measurement parameters, e.g., DPD colorimetric method for residual chlorine, zero-point gel for oxygen sensors.
Maintenance and Replacement Steps
Regular maintenance can extend equipment life. The following are general steps:
- Turn off power and drain the pipeline.
- Remove the measuring chamber, check the seals, and replace if necessary (Order No. 71268482).
- Replace the membrane and electrolyte; using the maintenance kit (Order No. 71076922) simplifies the operation.
- Clean the sensor and treat the electrode with polishing foil.
- Reassemble and calibrate, verify using PF-3 or COY8.
Spare Parts Parameter Comparison
For convenient selection, the following table summarizes the parameters of key spare parts:
| Order No. | Name | Specification | Applicable Model |
|---|---|---|---|
| 71268479 | Measuring chamber | Kit CCSx4x/142D | CCS240 |
| 71268482 | Seals | x2 | CCS240 |
| 50005255 | Membrane replacement | 2-pack | CCS 140/141/240/241 |
| 50064294 | Electrolyte | 50 ml | CCS 240/241 |
| 71076922 | Maintenance kit | Electrolyte 50ml, 2 membrane caps, polishing foil | CCS24x |
| 50005181 | Junction box VBC | IP65 | CMK measuring cable |
| 50085333 | Measuring cable | Priced per meter, minimum 5 meters | pH/redox/conductivity/current electrode |
| 71257946 | Handheld DPD colorimetric calibration instrument PF-3 | 0.05-6mg/l, IP67 | Disinfection, drinking water, process water |
| COY8- | Zero-point gel COY8 | 12/25/40mm | Oxygen and disinfection sensors |
Summary
The CCS240 spare parts list provided in this article covers common spare parts and their specifications. When selecting, pay attention to compatibility and maintenance needs. Reasonable spare parts inventory can reduce downtime and ensure stable operation of the analyzer. For more information, please refer to the product manual or contact the supplier.