CUE25 Spare Parts List Overview
CUE25/CUE26 are industrial instruments used for turbidity measurement, and the selection of their spare parts directly affects measurement accuracy and maintenance efficiency. This article compiles two commonly used spare parts: calibration kit and sample measuring glass tubes, providing order numbers, descriptions, recommendation levels, and location group information for quick reference by engineering technicians and procurement personnel.
Detailed Spare Parts List
The table below lists the recommended spare parts and their key parameters for CUE25/CUE26. All spare parts are marked as "Recommended", the location group is "Not classified", and the valid status is "A" (valid).
| Order Number | Description | Recommended | Tk | Location | Group | Valid |
|---|---|---|---|---|---|---|
| 51518582 | Calibration kit for CUE25/CUE26 Ready-for-use solutions 0.02 NTU, 10 NTU and 1000 NTU Accessory turbidity measurement | A | - | Not classified | - | A |
| 51518583 | Sample measuring glass tubes for CUE25/CUE26 incl. caps, 3 pcs. Accessory turbidity measurement | A | - | Not classified | - | A |
Calibration Kit (Order Number 51518582)
This kit contains three ready-to-use standard solutions: 0.02 NTU, 10 NTU, and 1000 NTU, suitable for calibration of CUE25/CUE26 turbidity meters. Using ready-to-use solutions reduces human preparation errors and ensures traceability of measurement results.
- Application scenarios: Regular calibration, verification of instrument performance.
- Recommendation level: A (Recommended).
- Location group: Not classified (general spare part).
Sample Measuring Glass Tubes (Order Number 51518583)
This spare part includes 3 glass tubes with caps, specifically for sample measurement of CUE25/CUE26. The optical quality of the glass tubes directly affects turbidity readings, so it is recommended to use original spare parts to ensure consistency.
- Packaging quantity: 3 pcs/set.
- Accessories: Includes caps.
- Recommendation level: A (Recommended).
Selection and Usage Recommendations
To ensure long-term stable operation of CUE25/CUE26, it is recommended to purchase the above spare parts in advance according to the maintenance cycle. The calibration kit should be replaced regularly to avoid expiration of standard solutions; sample glass tubes should be replaced promptly when scratches or contamination occur.
- Confirm the instrument model is CUE25 or CUE26.
- Select the calibration kit (51518582) according to calibration needs.
- Select the quantity of glass tubes (51518583) according to sample measurement frequency.
- Verify the order number and description to avoid incorrect purchase.
For more spare parts information, please refer to the official spare parts manual or contact technical support.