CUE21 Turbidity Meter Spare Parts Overview
CUE21 is an industrial instrument used for continuous turbidity measurement, widely applied in water treatment, chemical, and environmental monitoring fields. To ensure measurement accuracy and equipment lifespan, timely replacement of original spare parts is crucial. This article compiles the list of maintenance spare parts and accessories for CUE21 and compatible models, including order numbers, specifications, and purposes, facilitating quick selection by engineering personnel and procurement.

Core Maintenance Spare Parts
Electronic Modules and Junction Boxes
The electronic module is the core component of turbidity measurement, responsible for signal processing and light source driving. The on-site junction box provides power access and protection, ensuring stable operation of the transmitter. The following are key maintenance spare parts parameters:
| Order Number | Name | Specifications/Parameters | Purpose |
|---|---|---|---|
| 71030103 | CUE21 Maintenance Electronic Module | Light source: Infrared LED (850 nm); Range: 0-1000 NTU | Turbidity measurement maintenance spare part |
| 71030105 | On-site Junction Box CUE21/CUE22 | Supply voltage: 100-240 VAC | Turbidity measurement maintenance spare part |
Note: After replacing the electronic module, recalibration is required to ensure measurement accuracy.
Desiccants and Fittings
Desiccants are used to absorb moisture inside the instrument to prevent condensation on optical components; fittings are used to connect the flow cell and piping. Both are routine maintenance consumables.
- 51518578: CUE21/CUE22 desiccant, refill pack, turbidity measurement accessory
- 51518579: CUE21/CUE22 fittings, turbidity measurement accessory
Cleaning and Calibration Accessories
Ultrasonic Cleaning Glass Tube
The ultrasonic cleaning glass tube effectively removes deposits on the glass surface, reducing manual cleaning frequency. Order number 51518576, suitable for CUE21/CUE22, belongs to turbidity measurement accessories.
Calibration Kit
The calibration kit contains ready-to-use standard solutions for quick calibration of the instrument. Order number 51518580, suitable for CUE21/CUE23/CUE24, standard solution concentrations include 0.02 NTU, 10 NTU, and 1000 NTU.
- 0.02 NTU: Low range calibration point
- 10 NTU: Medium range calibration point
- 1000 NTU: High range calibration point
Flow Cell and Adjustment Components
Flow Chamber and O-ring
The flow chamber is used to suppress bubble interference and ensure measurement stability. The O-ring is used for sealing to prevent leakage. Related spare parts are as follows:
- 51518575: CUE21/CUE22 flow chamber, used for bubble suppression, turbidity measurement accessory
- 71267830: O-ring
Pressure Regulator and Flow Regulator
The pressure regulator and flow regulator are used to control sample flow rate and pressure, ensuring consistent measurement conditions. Order numbers 71085512 (pressure regulator CUE21/22) and 71267825 (flow cell flow regulator).
Spare Parts Selection Recommendations
To ensure long-term stable operation of the turbidity measurement system, it is recommended to stock consumable parts in advance according to the maintenance cycle. The following are common selection references:
| Maintenance Scenario | Recommended Spare Part | Order Number |
|---|---|---|
| Electronic module failure | Maintenance electronic module | 71030103 |
| Power wiring failure | On-site junction box | 71030105 |
| Moisture protection maintenance | Desiccant | 51518578 |
| Piping connection | Fittings | 51518579 |
| Glass tube cleaning | Ultrasonic cleaning glass tube | 51518576 |
| Regular calibration | Calibration kit | 51518580 |
| Bubble interference | Flow chamber | 51518575 |
| Pressure adjustment | Pressure regulator | 71085512 |
| Seal replacement | O-ring | 71267830 |
| Flow control | Flow regulator | 71267825 |
Summary: The spare parts system of the CUE21 turbidity meter covers multiple aspects including electronics, mechanics, optics, and calibration. Proper selection of original spare parts can extend instrument lifespan and reduce downtime risk. Users are advised to formulate a spare parts inventory plan based on actual working conditions.