Nr

Order code

Specification

52018765

Weld-in adapter

Flush mount process connection

FTL20 "1",

FTL20H "GDJ",

FMI51, FTI51 "GQJ"

Material: 316L, EHEDG compliant

Seal: Silicone O-ring

Inspection cert. EN10204-3.1 material

(316L wetted parts)

52021717

O-ring

for weld-in adapter G3/4 D=50 316L

Liquiphant T FTL20H

52028295

Weld-in adapter

Flush mount process connection

FTL20 "1",

FTL20H "GDJ"

w/o flange

Material: 316L, EHEDG compliant

Seal: Silicone O-ring

Inspection cert. EN10204-3.1 material

(316L wetted parts)

52001052

Weld-in adapter

Flush mount process connection

FTL50/FTL50H "GQ2"

Material: 316L

Seal: Silicone O-ring

52011897

Weld-in adapter

Flush mount process connection.

Material: 316L.

Inspection cert. EN10204-3.1 material.

Seal: silicone O-ring.

FDA, 3-A compliant.

additional EPDM O-ring.

FDA, EHEDG, 3-A, USP Class VI compliant.

Usage: FTL41 FTL50, FTL50H, FTL51B,

FTL63, FTL80, QMW43, TMR35.

52014473

O-ring

for weld-in adapter G3/4

Liquiphant M "GQ2"

52001051

Process connection|Weld-in G1, d=60, 316L

Flush mount process connection

FTL260 "0",

FTL20 "7",

FTL20H "GEJ",

FTL330H/FTL330L "G",

FTL50/FTL51, FTL50H/FTL51H "GW2",

FMI51/FMI52, FTI51/FTI52 "GWJ",

PMP135 "N",

PTP35 "BB"

Material: 316L

Seal: Silicone O-ring

52011896

Weld-in adapter, G1, d=60, 3.1 material certificate

Flush mount process connection

FTL260 "0",

FTL20H "GEJ",

FTL50/FTL51, FTL50H/FTL51H "GW2",

FMI51/FMI52, FTI51/FTI52 "GWJ",

PMP135 "N",

PTP35 "BB"

Material: 316L

Seal: Silicone O-ring

Inspection cert. EN10204-3.1 material

(316L wetted parts)

71093129

Weld-in adapter

Flush mount process connection.

Material: 316L.

Inspection cert. EN10204-3.1 material

Seal: silicone O-ring

FDA, 3-A compliant.

Additional EPDM O-ring.

FDA, EHEDG, 3-A, USP Class VI compliant.

Usage: FMI51, FMI52, FTI51, FTI52,

FTL31, FTL20H, FTL33, FTL41, FTL50,

FTL50H, FTL51, FTL51B, FTL51H, FTL63,

FTL80, FTL81, FTL260, PMP135, PTP35,

PTP33B, PMP23, PMP51, FTW23, FTW33,

QMW43.

52014472

O-ring

for weld-in adapter G1 (52001051)

Liquiphant M "GW2"

Liquiphant T "7",

Liquicap M "GWJ",

Cerabar T PMP135 "N",

Ceraphant T PTP35 "BB"

for weld-in adapter G1, 316L 3.1

(52011896)

Liquiphant M "GW2",

Cerabar T PMP135 "N",

Ceraphant T PTP35 "BB"

for sliding sleeve

Soliphant T

52001221

Weld-in adapter

Flush mount process connection

FTL260 "0",

FTL20 "7",

FTL20H "GEJ",

FTL330H/FTL330L "G",

FTL50/FTL51, FTL50H/FTL51H "GW2"

Liquiphant is adjustable

Material: 316L

Seal: Silicone O-ring

52011898

Weld-in adapter

Flush mount process connection

FTL260 "0",

FTL20H "GEJ",

FTL50/FTL51, FTL50H/FTL51H "GW2"

Liquiphant is adjustable

Material: 316L

Seal: Silicone O-ring

Inspection cert. EN10204-3.1 material

(316L wetted parts)

52014424

Sealing gasket

for weld-in adapter G1,

adjustable, 316L (52001221)

Liquiphant M "GW2"

for weld-in adapter G1,

adjustable, 316L (52011898)

Liquiphant M "GW2"

for weld-in adapter G1, adjustable

Liquiphant FTL330H/FTL330L,

Liquiphant T FTL20H "UPJ

71044062

Device package

2x screws, 1x sealing CDI-connector

71182602

Seal

5x O-ring 3.69x1.78

5x O-ring 74.7x2.75

71182606

Seal

5x O-ring 57x2.5

5x O-ring 64.3x1.8 blue

71383294

Gasket

Packing unit: 10 pieces

71038252

Fixing kit cpl.TMT180,181,182,187 USA

51516983

Communication interface FXA291

Serial USB Computer Interface

Technical Data:

- USB Version1.1 or higher

- Power supply via USB

- IP51; NEMA/Typ 3

- Ambient temperature: -20....+60oC

- Ex: II(2) G (EEx ia) II C

- ATEX: BVS 05 ATEX E 095

Scope of delivery:

Commubox FXA 291

MS Windows USB driver

Device is submitted for CSA/FM

application.

The device may not be modified and may

be used with intrinsically safe circuits

with corresponding characteristics only

(see safety certificate).

TID10-

Temperature transmitter display TID10

to plug on.

Dot-Matrix measured value display.

12 DIP-switches bottom side.

Settings:

FF: Simulation, Write Lock.

PA: Bus address, Write Lock.

Compatible: TMT85, TMT84.

A1

Z2

TMT31-

Temperature transmitter TMT31

2-wire temperature transmitter.

Single sensor input.

Application: RTD.

Factory setup w/o additional

specification:Pt100, 4-wire, 0...+100oC,

presetting failure current low.

Mounting: head form B, DIN EN50446.

CA

A

1

A

B

1

A1

B2

B3

C1

IB

PB

Z2

Z9

TMT36-

iTEMP TMT36, Transmitter IO-Link

2-wire temperature transmitter.

Single sensor input.

Application: RTD.

Factory setup w/o additional

specification: Pt100, 4-wire, oC.

Mounting: head form B, DIN EN50446.

CA

A

1

A

B

1

AC

A1

B2

B3

C1

Z2

TMT71-

Temperature transmitter TMT71

2-wire temperature transmitter.

Single universal sensor input.

Galvanic isolation 2kV (input/output).

Application: RTD, TC, Ohm and mV.

Factory setup w/o additional

specification:Pt100, 4-wire, 0...+100oC.

CA

A

P

1

A

B

AC

A1

B2

B3

C1

H1

H2

Z2

TMT72-

Temperature transmitter TMT72

2-wire temperature transmitter.

Single universal sensor input.

Galvanic isolation 2kV (input/output).

Application: RTD, TC, Ohm and mV.

Factory setup w/o additional

specification: Pt100, 4-wire, 0...+100oC

CA

A

P

1

A

B

AC

A1

B2

B3

C1

H1

H2

Z2

B

TMT82-

Module temperature transmitter TMT82

2-wire temperature transmitter.

Dual universal sensor input.

Galvanic isolation 2kV (input/output).

Application: RTD, TC, Ohm and mV.

Presetting failure current high.

::Highly reliable due to drift

detection and sensor back up.

::Optional also for safety critical

applications by means of SIL 2/3

acc. to IEC61508.

AA

A

1

2

B

B1

C1

A1

AA

A1

LA

Z2

DIENST-

Service

F

T

A

TA30A-

Terminal head TA30A

Retainer for terminal block or head

transmitter + optional display.

Cover: low, hinged, optional window.

Material: aluminium.

Coating: polyester powder-coating.

Colour: body blue, cover grey.

Ambient temp.: -50...150 oC (housing).

Protection: IP66/68, NEMA 4X (housing).

2

A

B

1

A1

TA30R-

Terminal box TA30R

Retainer for terminal block

or head transmitter + optional display.

Cover: screwed, optional window.

Material: Stainless Steel 316L.

Colour: Steel (no coating).

Ambient Temp.: -50...85/130 oC

(display/standard).

Protection: IP66/68, NEMA4X;

IP69K (housing).

:: easy wiring through best

accessibility.

:: compact design and low weight.

A

B

2

B

1

2

C1

C4

TA30S-

Terminal box TA30S

Retainer for terminal block or head

transmitter.

Cover: screwed.

Material: Polypropylene.

Colour: white.

Ambient Temperature: -30...+130oC.

Protection: IP65, NEMA4X (housing).

:: easy wiring through good

accessibility.

:: compact design, low weight.

2

A

B

C

C1

FXA195-

Communication interface FXA195

Modem to connect HART field devices

to a computer via USB. Commissioning of

field devices with software tool.

:: To connect to a intrinsically safe

signal circuit.

:: SIL2, IEC61508.

G

1

TXU10-

Device commissioning package TXU10

For devices that can be programmed and commissioned via PC

Program settings + connection cable for PC with USB interface

BD

SFE500-

Plant asset management system FieldCare SFE500

FieldCare is a software tool that

combines the best of the leading

device integration technologies FDT

and FDI. FieldCare is scalable which

allows to fulfill tasks from easy

Device Setup, Plant Asset Management

or Condition Monitoring (Asset Health

Monitoring).

FieldCare includes approved DTM and FDI

Package libraries from Endress+Hauser

and third party.

Additional hardware e.g. modems or

communication interfaces are needed.

One year software update service is

included to guarantee top quality,

security and performance via online

updates or download from the

Endress+Hauser Software Portal:

https://software-products.endress.com

N

B

C

B

1

0

1

FXA42-

Fieldgate FXA42

Compact gateway for data capture

of field devices, without antenna.

Embedded web server,

alarm / event handling.

Application: remote monitoring,

inventory data monitoring,

web enabled field interface.

Field device interfaces 4-20mA,

Modbus RTU, digital inputs/outputs.

:: Meets NAMUR NE43 requirements.