TR13 Thermometer Spare Parts List Overview
The TR13 thermometer is a commonly used instrument in industrial temperature measurement, and its spare parts management is crucial for maintenance and procurement. This spare parts list includes various spare parts required for the TR13 thermometer, such as heat transfer oil, gaskets, ceramic terminals, sensors, transmitters, etc., and provides order numbers, descriptions, recommendation levels, positions, and group information. The following content will help you quickly find and select the correct spare parts.
Detailed Spare Parts List
The table below lists the spare parts information for the TR13 thermometer, including order number, description, recommendation level (A means commonly used, S means standard, + means optional, T means tool), position, and group.
| Order Number | Description | Recommendation | Position | Group | |
|---|---|---|---|---|---|
| 71249291 | Heat transfer oil FDA certified 30g | A | Not classified | ||
| 71312729 | Heat transfer oil HSC 340, 100g | A | Not classified | ||
| 71367427 | Packing unit: 10 pieces | S | Not classified | ||
| 71111513 | Ceramic terminal | A | C | Terminal module | |
| 71111514 | Ceramic terminal | A | C | Terminal module | |
| 71111515 | Ceramic terminal | A | C | Terminal module | |
| 52028179 | Profile gasket for cover Stainless steel housing F15 | S | Not classified | ||
| 60017971 | Display LC for TA20J | S | Not classified | ||
| 71043745 | Pressure compensation filter Consists of: filter plug plastic, Pressure compensation filter, O-ring. Usage: housing F15. Non Ex. | S | Not classified | ||
| 71044061 | Device package 2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connector | S | Not classified | ||
| 71313382 | Connector | S | Not classified | ||
| 71142762 | O-ring | S | Not classified | ||
| TS111- | iTHERM TS111 insert Replaceable. Metric version according DIN43735. | + | S | Sensor | |
| TPR100- | RTD insert TPR100 Mineral insulated cable (MgO) Replaceable insert acc. EN60751. max. measuring range: -200...600 oC (depending on configuration) | + | S | Sensor | |
| TA730- | Protection tube TA730 In PTFE, PVDF, Tantalum or Titanium for thermowells **TW13, TR13 and TC13 according to DIN Form F. Formula for calculating the total length: Titanium or Tantalum: TL = U + 3mm (0.12in) PTFE: TL = U + 15mm (0.6in) PVDF: TL = U + 18mm (0.71in) | S | F | Assembly/armored accessories | |
| TW13- | **Protection tube TW13 with flange connection. Protection tube acc. DIN 43772 /2F+3F welded version. | S | E | Assembly/armored | |
| TR88- | **RTD TR88 to screw-in. Neck DIN43772. Replaceable insert, MgO. max. measuring range: -200...600 oC (depending on configuration) | S | Not classified | ||
| TA20A- | **Connection head TA20A Product being phased out, limited availability. Connection head to mount a measuring insert with head transmitter or a connection socket. To be mounted on an armature or protective sleeve. Material: Aluminium epoxy resin coating Area temperature: max. +100 oC; ATEX: +95 oC. | S | D | Housing/housing accessories | |
| TA20B- | Connection head TA20B Connecting head to mount a measuring insert with head transmitter or a connection socket. To be mounted on an armature or protective sleeve. Material: Polyamid black Ambient temperature: max. +80 oC Protection: IP65 | S | D | Housing/housing accessories | |
| TA20D- | **Connection head TA20D Product Phased Out. Connection head to mount a measuring insert with up to two head transmitters or a connection socket and one head transmitter. For mounting on armature or protection sleeve. Material: Aluminium, varnished Ambient temperature: max. +100 oC; ATEX: +95 oC. Protection: IP66 | S | D | Housing/housing accessories | |
| TA20R- | **Connection head TA20R Stainless steel AISI 316L W 1.4404. Max temperature 100 oC, ATEX: +95 oC. Protection class IP66/IP67 | S | D | Housing/housing accessories | |
| TA20W- | **Connection head TA20W Product Phased Out. Connection head hinged to mount a measuring insert with head transmitter or connection socket. To be mounted on an armature or a protection sleeve. Material: Aluminium Area temperature: max. +100 oC; ATEX: +95 oC Protection: IP66 | S | D | Housing/housing accessories | |
| TA21E- | Connection head TA21E Retainer for terminal block or head transmitter. Cover: screwable. Material: Aluminum. Max. temp.: +100 oC; ATEX +95 oC. Protection: IP65. | S | D | Housing/housing accessories | |
| TMT84- | Module temperature transmitter TMT84 Dual sensor input. Advanced diagnostics: sensor monitoring. Galvanic isolation 2kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. Factory setup: CH1: Pt100, 3-wire, oC CH2: inactive Differing configuration optional selectable. | + | S | B | Electronic (sensor) |
| TMT85- | Module temperature transmitter TMT85 Temperature transmitter with dual sensor input and advanced diagnostics for sensor monitoring. FOUNDATION Fieldbus protocol (ITK 5.0). Galvanic isolation 2 kV (sensor input to the output). Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. UL listed, CSA General Purpose. | + | S | B | Electronic (sensor) |
| TID10- | Temperature transmitter display TID10 to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84. | + | S | B | Electronic (sensor) |
| READWIN- | Readwin 2000 commissioning package READWIN Readwin 2000 Operation + Read. software | T | Not classified | ||
| TXU10- | Instrument commissioning package TXU10 For device program setting that can be PC programmed and commissioned + connection cable for PC with USB interface | + | A | Not classified | |
| FXA195- | Communication interface FXA195 Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508. | T | Not classified | ||
| TA30A- | Connection head TA30A Retainer for terminal block or head transmitter + optional display. Cover: low, hinged, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing). | S | D | Housing/housing accessories | |
| TA30D- | Connection head TA30D Retainer for 2 head transmitters or terminal blocks. Cover: high, hinged. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing). | S | D | Housing/housing accessories | |
| TA30P- | Connection head TA30P Retainer for 2 head transmitters or terminal blocks. Cover: high, hinged. Material: Polyamid PA12 antistatic. Colour: black. Ambient temp.: -40...120oC (housing). Protection: IP65 (housing). | S | D | Housing/housing accessories | |
| TMT180- | Module temperature transmitter TMT180 Temperature transmitter, PC-programable. Application: RTD. 2-wire 4-20mA. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed. | + | S | B | Electronic (sensor) |
| TMT181- | **Module temperature transmitter TMT181 Product being phased out, limited availability. Temperature transmitter, PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed. | + | S | B | Electronic (sensor) |
| TMT182- | **Module temperature transmitter TMT182 Temperature transmitter, Protocol HART. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, SIL2, galvanic isolation Fault reaction: NAMUR NE 43. Mounting: head form B, DIN43729. UL listed. GL (German Llyod) Marine. | + | S | B | Electronic (sensor) |
| TMT82- | Module temperature transmitter TMT82 2-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. :: Highly reliable due to drift detection and sensor back up. :: Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508. | + | S | B | Electronic (sensor) |
| DIENST- | Service | A | Not classified | ||
| TR13- | **RTD TR13 with flange connection. Thermowell acc. DIN43772/2F+3F. Replaceable insert, MgO. max. measuring range: -200...600 oC. (depending on configuration). | S | Not classified | ||
| XPRFID- | RFID TAG as spare part available only for instruments with option TZD, marking RFID TAG Spare RFID TAG Consists of: RFID TAG, fixing wire, crimp sleeve. | S | Not classified |
Spare Parts Selection and Usage Recommendations
How to Choose Heat Transfer Oil
Heat transfer oil is used for thermometer heat transfer to ensure measurement accuracy. It is recommended to use FDA certified heat transfer oil (30g) or HSC 340 heat transfer oil (100g), depending on the application environment. FDA certification is suitable for the food and pharmaceutical industries, while HSC 340 is suitable for high-temperature environments.
Gaskets and Seals
Gaskets and O-rings are used for sealing to prevent leakage. The spare parts list provides Packing unit (10 pieces) and O-ring. It is recommended to check and replace them regularly.
Sensors and Transmitters
Sensors are the core components of the thermometer. Spare parts include TS111 insert, TPR100 RTD insert, etc., all conforming to DIN standards. Transmitters such as TMT84 and TMT85 support multiple signal inputs and have advanced diagnostic functions. When selecting, pay attention to the measuring range, output signal, and certification requirements.
Housings and Accessories
Connection heads and housings protect internal components. Spare parts include TA20 series, TA30 series, etc., with materials including aluminum, stainless steel, and plastic, suitable for different environments. The protection level is up to IP68, meeting harsh industrial environments.
Frequently Asked Questions (FAQ)
- How to determine the recommendation level of spare parts? Recommendation level A indicates commonly used spare parts, S indicates standard spare parts, + indicates optional, and T indicates tools. Choose according to maintenance needs.
- Are spare parts applicable to other models? Some spare parts such as sensors and transmitters may be universal, but it is recommended to check the model and specifications.
- How to obtain technical support? Contact the supplier or refer to official documentation to ensure correct selection.
Summary
The TR13 thermometer spare parts list provides comprehensive spare parts information to help you quickly locate the required components. Correct selection and regular replacement of spare parts can ensure long-term stable operation of the thermometer. For more information, please consult professional technical personnel.