TSM187 Temperature Transmitter Spare Parts List Overview

TSM187 is a modular temperature transmitter commonly used in industrial temperature measurement, and its spare parts list enumerates the key components required for maintenance and replacement. This table is compiled based on original data and aims to help engineering technicians and procurement personnel quickly identify and order spare parts.

Spare Parts List

  • Order number 71111514: Ceramic terminal block, used for electrical connection.
  • Order number 51001112: Temperature transmitter spare parts, including 4 screws, 6 springs, and 10 spring washers.
  • TPR100-: RTD insert TPR100, using mineral-insulated cable (MgO), compliant with EN60751 standard, replaceable insert, maximum measuring range -200...600°C (depending on configuration).

TMT187 Modular Temperature Transmitter Technical Parameters

TMT187 is a modular temperature transmitter used for RTDs, featuring 2-wire, 4-20mA output, and electrical isolation. Its error alarm complies with NAMUR NE 43 standard, the mounting method is terminal box DIN B EN 50446, and it has UL and GL (Germanischer Lloyd) certifications.

Key Features

  • Application: RTD
  • Output: 2-wire, 4-20mA, electrical isolation
  • Error alarm: NAMUR NE 43
  • Mounting method: Terminal box DIN B EN 50446
  • Certification: UL, GL (Germanischer Lloyd)

Ordering Code Description

The ordering code for TSM187 consists of multiple options. The following are some code examples and their meanings:

CodeDescription
ABasic model
AFOption AF
AHOption AH
AMOption AM
ATOption AT
2Option 2
FOption F
3Option 3
0Option 0
0Option 0
0Option 0

For TMT187, the ordering code includes: A, 4, 1, DD, FE, FH, FJ, A. Please refer to the product manual for specific meanings.

Selection and Maintenance Recommendations

When selecting TSM187 spare parts, it is necessary to confirm the transmitter model, measuring range, and certification requirements. Regularly inspect the ceramic terminal block and temperature transmitter spare parts to ensure reliable connections. The RTD insert TPR100 can be replaced according to the configuration; note that the measuring range should not exceed 600°C.