TST434 Spare Parts List Overview
This article provides the TST434 series spare parts list, covering temperature transmitters, terminal boxes, communication interfaces, and other spare parts. It is suitable for maintenance and procurement in the industrial automation field.
Temperature Transmitters
TMT180 Modular Temperature Transmitter
TMT180 is a PC-programmable temperature transmitter for RTD sensors, with a 2-wire 4-20mA output. Fault response complies with NAMUR NE 43, mounting form is Type B head, compliant with DIN EN50446, UL certified.
- Application: RTD
- Output: 2-wire 4-20mA
- Fault response: NAMUR NE 43
- Mounting: Type B head, DIN EN50446
- Certification: UL listed
Selection options:
| Option | Code | Description |
|---|---|---|
| Certification | A | Non-hazardous area |
| Programming | 1 | Via PC |
| Programming | 2 | Locked |
| Measuring range/accuracy | 1 | -200...650°C; 0.2K / 0.08% span |
| Measuring range/accuracy | 2 | -50...250°C; 0.1K / 0.08% span |
| Configuration connection | 3 | RTD 3-wire |
| Configuration connection | 4 | RTD 4-wire |
| Configuration range | XX | See additional specifications, minimum span 10K |
| Additional option | A | Standard DIN mounting kit |
TMT181 Modular Temperature Transmitter
TMT181 is a PC-programmable temperature transmitter supporting RTD, TC, Ohm, mV inputs, with a 2-wire 4-20mA output and electrical isolation. Fault response complies with NAMUR NE 43, mounting form is Type B head, compliant with DIN EN50446, UL certified.
- Application: RTD, TC, Ohm, mV
- Output: 2-wire 4-20mA, electrical isolation
- Fault response: NAMUR NE 43
- Mounting: Type B head, DIN EN50446
- Certification: UL listed
Selection options:
| Option | Code | Description |
|---|---|---|
| Certification | A | Non-hazardous area |
| Certification | B | ATEX II1G Ex ia IIC T4/T5/T6 |
| Certification | I | FM+CSA IS, NI, Class I, Div.1+2, Group ABCD |
| Configuration connection | 3 | RTD 3-wire |
| Configuration connection | 4 | RTD 4-wire |
| Configuration sensor type | 1 | Pt100, -200...850°C, minimum span 10K, IEC751 (α=0.00385) |
| Configuration | B | Measuring range, see additional specifications |
| Additional option | A | Standard DIN mounting kit |
TMT84 Modular Temperature Transmitter
TMT84 features dual sensor inputs and advanced diagnostics, supporting sensor monitoring. Electrical isolation 2kV, suitable for RTD, TC, Ohm, mV. Current consumption 11mA, mounting form is Type B head, compliant with DIN43729.
- Dual sensor inputs
- Advanced diagnostics: sensor monitoring
- Electrical isolation: 2kV
- Application: RTD, TC, Ohm, mV
- Current consumption: 11mA
- Mounting: Type B head, DIN43729
Factory settings: CH1: Pt100, 3-wire, °C; CH2: inactive. Different configurations available.
Selection options:
| Option | Code | Description |
|---|---|---|
| Certification | A1 | Non-hazardous area |
| Certification | B1 | ATEX II1G Ex ia IIC T4/T5/T6 |
| Output signal | A | PROFIBUS PA |
| Electrical connection | 1 | Spring terminals, Type B housing, DIN EN 50446 |
| Electrical connection | 2 | Screw terminals, Type B housing, DIN EN 50446 |
| Field housing | A | None, DIN standard mounting kit |
| Configuration input | B1 | Ch1: RTD 3-wire, Ch2: inactive |
| Configuration input | C1 | Ch1: RTD 4-wire, Ch2: inactive |
TMT85 Modular Temperature Transmitter
TMT85 features dual sensor inputs and advanced diagnostics, supporting FOUNDATION Fieldbus protocol (ITK 5.0). Electrical isolation 2kV, suitable for RTD, TC, Ohm, mV. Current consumption 11mA, mounting form is Type B head, compliant with DIN43729. UL listed, CSA General Purpose.
- Dual sensor inputs
- Advanced diagnostics: sensor monitoring
- Protocol: FOUNDATION Fieldbus (ITK 5.0)
- Electrical isolation: 2kV
- Application: RTD, TC, Ohm, mV
- Current consumption: 11mA
- Mounting: Type B head, DIN43729
- Certification: UL listed, CSA General Purpose
Selection options:
| Option | Code | Description |
|---|---|---|
| Certification | A1 | Non-hazardous area |
| Certification | B1 | ATEX II1G Ex ia IIC T4/T5/T6 |
| Output signal | A | FOUNDATION Fieldbus H1 |
| Electrical connection | 1 | Spring terminals, Type B housing, DIN EN 50446 |
| Electrical connection | 2 | Screw terminals, Type B housing, DIN EN 50446 |
| Field housing | A | None, DIN standard mounting kit |
| Configuration input | B1 | Ch1: RTD 3-wire, Ch2: inactive |
| Configuration input | C1 | Ch1: RTD 4-wire, Ch2: inactive |
TMT182 Modular Temperature Transmitter
TMT182 is a HART protocol temperature transmitter, supporting RTD, TC, Ohm, mV inputs, with a 2-wire 4-20mA output, SIL2, electrical isolation. Fault response complies with NAMUR NE 43, mounting form is Type B head, compliant with DIN43729. UL listed, GL (Germanischer Lloyd) marine certified.
- Protocol: HART
- Application: RTD, TC, Ohm, mV
- Output: 2-wire 4-20mA, SIL2, electrical isolation
- Fault response: NAMUR NE 43
- Mounting: Type B head, DIN43729
- Certification: UL listed, GL Marine
Selection options:
| Option | Code | Description |
|---|---|---|
| Certification | A | Non-hazardous area |
| Certification | B | ATEX II1G Ex ia IIC T4/T5/T6 |
| Certification | I | FM+CSA IS, NI, Class I, Div.1+2, Group ABCD |
| Configuration connection | E | RTD 3-wire, non-SIL |
| Configuration connection | F | RTD 4-wire, non-SIL |
| Configuration sensor type | 1 | Pt100, -200...850°C, minimum span 10K, IEC751 (α=0.00385) |
| Configuration | B | Measuring range, see additional specifications |
| Additional option | A | Standard DIN mounting kit |
| Additional option | B |
TMT82 Modular Temperature Transmitter
TMT82 is a 2-wire temperature transmitter with dual universal sensor inputs and electrical isolation 2kV. Supports RTD, TC, Ohm, and mV. High reliability through drift detection and sensor backup. Optional SIL 2/3 certification, suitable for safety-critical applications.
- 2-wire
- Dual universal sensor inputs
- Electrical isolation: 2kV (input/output)
- Application: RTD, TC, Ohm, mV
- High reliability: drift detection and sensor backup
- Optional SIL 2/3: compliant with IEC61508
Selection options:
| Option | Code | Description |
|---|---|---|
| Certification | 8C | FM+CSA IS, NI I/1+2/A-D |
| Certification | AA | Non-hazardous area |
| Certification | BA | ATEX II1G Ex ia IIC T4/T5/T6 |
| Communication; output signal | A | HART; 1x 4-20 mA |
| Electrical connection | 1 | Spring terminals, Type B housing, DIN EN 50446 |
| Electrical connection | 2 | Screw terminals, Type B housing, DIN EN 50446 |
| Field housing | A | None, DIN standard mounting kit |
| Configuration universal input | B1 | Ch1: RTD 3-wire, Ch2: inactive |
| Configuration universal input | C1 | Ch1: RTD 4-wire, Ch2: inactive |
| Sensor type input 1 | A1 | Pt100, -200...850°C, minimum span 10K, IEC60751 (α=0.00385) |
| Sensor type input 2 | AA | Inactive |
| Input; interconnection | A1 | PV = CH1; CH2 inactive |
| Additional certification | LA | SIL compliance |
Communication Interfaces
FXA195 Communication Interface
FXA195 is a modem used to connect HART field devices to a computer via USB. Use software tools to commission field devices. Can be connected to intrinsically safe signal circuits. Compliant with SIL2, IEC61508.
- Function: HART field device to computer USB connection
- Application: field device commissioning
- Safety: can be connected to intrinsically safe signal circuits
- Certification: SIL2, IEC61508
Selection options:
| Option | Code | Description |
|---|---|---|
| Certification | G | ATEX II (1)GD [EEx ia] IIC |
| Additional option | 1 | Basic version |
READWIN 2000 Commissioning Package
READWIN 2000 is an operating and reading software.
- Storage medium: CD
- Software: E+H
Terminal Boxes
TA20A Terminal Box
TA20A product is being phased out, limited supply. Used to install measuring inserts with head transmitters or connection sockets. Can be mounted on brackets or protective tubes. Material: aluminum epoxy resin coating. Area temperature: max +100°C; ATEX: +95°C.
- Thermometer connection: M24x1.5
- Cable entry: M20 cable gland
- Color: housing blue, cover gray
- Label: standard E+H
TA30A Terminal Head
TA30A used to secure terminal blocks or head transmitters and optional display. Cover: low, hinged, optional window. Material: aluminum. Coating: polyester powder coating. Color: body blue, cover gray. Ambient temperature: -50...150°C (housing). Protection: IP66/68, NEMA 4X (housing).
- Connection to protection tube assembly: thread M24x1.5
- Electrical connection: 1x thread M20x1.5 or 1x thread G1/2
- Display window: none
Cable gland options:
| Code | Description |
|---|---|
| A1 | 1x polyamide; -40...+100°C; IP68 |
| A2 | 1x polyamide ATEX; -20...+95°C; IP68 for dust explosion protection |
| A3 | 1x brass ATEX; -20...+130°C; IP68, NEMA 4X for dust explosion protection |
Other Spare Parts
Device Package (Order No. 71044061)
Device package includes: 2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connector.
TXU10 Instrument Commissioning Package
TXU10 instrument commissioning package is used for devices that can be PC-programmed and commissioned. Includes program settings and connection cable for PC with USB interface.
- Version: AA
- Includes: 4 pin plug + ReadWin2000