VEGAKON 61 Product Overview

VEGAKON 61 is a vibrating level switch launched by VEGA, mainly used for level limit detection of powdered and granular solid materials. The instrument is based on the tuning fork vibration principle. When the material covers the probe, the vibration frequency changes, thereby outputting a switching signal.

VEGAKON 61 is widely used in grain, chemical, building materials, plastics and other industries, suitable for measuring fine particles or powdered media. Its compact structure and easy installation make it a commonly used instrument in industrial level control.

VEGAKON 61 Chinese Manual Download

VEGAKON 61 Chinese Manual Download

To obtain the complete VEGAKON 61 Chinese manual, click the link below to download the PDF file. The manual contains detailed technical parameters, installation dimensions, electrical wiring, commissioning steps, and troubleshooting content.

  • File format: PDF
  • Language: Chinese
  • Applicable models: VEGAKON 61 series

Click to download VEGAKON 61 Chinese Manual.pdf

VEGAKON 61 Technical Parameters and Selection

Core Parameters Overview

ParameterTypical Value/Range
Measuring principleVibrating tuning fork
Applicable mediumPowdered, granular solids
Process temperature-40°C ~ +150°C
Process pressure-1 ~ +16 bar
Output signalRelay, transistor, NAMUR
Power supply20~250V AC/DC
Protection classIP66/IP67
Process connectionThread, flange

Selection Notes

  • Medium characteristics: Select the appropriate probe length and material according to particle size, density, and dielectric constant.
  • Process conditions: Confirm whether temperature and pressure are within the allowable range. For high temperatures, an extension tube is required.
  • Output mode: Select relay, transistor, or NAMUR output according to the control system interface.
  • Explosion-proof requirements: For explosive environments, choose intrinsically safe or flameproof type.

VEGAKON 61 Installation and Commissioning

Installation Steps

  1. Confirm the installation position and avoid direct impact of material on the probe. It is recommended to install on the side wall or top of the silo.
  2. According to the process connection type, weld or thread the flange/base to ensure good sealing.
  3. Screw in or flange-mount the VEGAKON 61, ensuring the probe extends an appropriate length into the silo.
  4. Connect the power supply and output signal lines according to the wiring diagram in the manual, paying attention to polarity and shielded grounding.
  5. After power-on, observe the indicator light and perform empty and full silo tests to confirm normal switching action.

Commissioning Points

  • Sensitivity adjustment: Adjust sensitivity according to material density to avoid false triggering.
  • Delay setting: A delay of 0.5~10 seconds can be set to prevent frequent switching caused by material fluctuation.
  • Status indication: The LED light displays the output status for quick on-site judgment.

Common Faults and Maintenance

Troubleshooting

SymptomPossible CauseSolution
No output signalPower not connected or wiring errorCheck power supply and wiring
False alarmSensitivity too high or material buildup on probeAdjust sensitivity, clean probe
Switch does not operateProbe damaged or medium density too lowReplace probe or select a more sensitive model

Daily Maintenance

  • Regularly check the probe for material adhesion, wear, or corrosion.
  • Clean the probe during shutdown to avoid scaling affecting vibration.
  • Check whether the cable sealing connector is loose to ensure the protection class.

Summary

VEGAKON 61 is a reliable solid level switch. Correct selection, installation, and commissioning can significantly improve measurement stability. It is recommended that engineering personnel download the VEGAKON 61 Chinese manual and strictly follow the specifications.

For more technical support, contact a VEGA authorized distributor or visit the official website.