VEGASON 61 Ultrasonic Level Transmitter Overview

VEGASON 61 is an ultrasonic level transmitter for continuous level measurement, suitable for non-contact measurement of liquids and bulk solids. Its core advantages are easy installation and reliable measurement, and it is widely used in water treatment, chemical, warehousing, and other industries.

This article provides the download of the VEGASON 61 Chinese manual and summarizes key technical and operational points for the convenience of engineering technicians and procurement personnel.

Download VEGASON 61 Chinese Manual.pdfDownload VEGASON 61 Chinese Manual.pdf

Working Principle and Main Features

Ultrasonic Measurement Principle

The VEGASON 61 emits ultrasonic pulses through the transducer. The sound waves reflect off the material surface and return to the transducer. The instrument calculates the level distance based on the time difference between transmission and reception.

This principle achieves non-contact measurement, is not affected by medium density, viscosity, and other parameters, and is suitable for corrosive liquids and powdered solids.

Core Features

  • Non-contact measurement: no wear, maintenance-free, suitable for applications with high hygiene requirements.
  • Wide measuring range: maximum range up to 15 m (depending on model and working conditions).
  • Flexible output signals: supports 4...20 mA/HART and other output methods.
  • Easy commissioning: parameters can be set via display module or PC software.

Key Technical Parameters

The following table lists typical technical parameters of the VEGASON 61 for selection reference. For specific values, please refer to the actual product nameplate and manual.

ParameterTypical Value
Measuring principleUltrasonic reflective
Measuring range0.4 ... 15 m
Process connectionThread / Flange
Process temperature-40 ... +80 °C
Process pressure-0.2 ... +2 bar
Output signal4 ... 20 mA / HART
Supply voltage14 ... 36 V DC
Protection ratingIP 66 / IP 67

Installation Steps and Precautions

Installation Steps

  1. Confirm the installation position: avoid the inlet, agitator, and tank wall, and ensure there are no obstructions within the sound beam cone.
  2. Install the flange or threaded connection: tighten according to the torque requirements in the manual to ensure sealing.
  3. Adjust the instrument orientation: make the transducer perpendicular to the material surface.
  4. Connect the cable: connect the power and signal lines according to the wiring diagram, and pay attention to shielding layer grounding.
  5. Power-on check: observe whether the display module starts normally.

Installation Precautions

  • Avoid installation in acoustic interference areas, such as places with foam, steam, or dense dust.
  • Ensure there is no material within the dead zone, otherwise measurement errors will occur.
  • For outdoor installation, a sunshade should be added to prevent high-temperature effects.

Commissioning and Parameter Setting

The VEGASON 61 supports commissioning via the display module or VEGACONNECT software. The basic steps include:

  1. Enter the empty tank height (distance from the flange face to the tank bottom).
  2. Set the full scale (distance corresponding to 100% level).
  3. Select the medium type (liquid or solid) to optimize signal processing.
  4. Adjust the damping time according to working conditions to suppress fluctuations.
  5. Save parameters and exit commissioning mode.

After commissioning is completed, it is recommended to perform multiple actual level comparisons to confirm measurement linearity.

Common Faults and Troubleshooting Methods

Fault SymptomPossible CauseTroubleshooting Method
No displayAbnormal power supplyCheck power supply voltage and wiring
Measured value jumpsAcoustic interferenceAdjust installation position or increase damping
Measured value remains constantMaterial in dead zoneLower installation position or increase dead zone setting
Abnormal output currentIncorrect parameter settingRecalibrate the range

Maintenance and Care Recommendations

  • Regularly check the transducer surface and remove dust or scaling.
  • Calibrate the output current every 6 months.
  • After long-term shutdown and restart, re-calibrate the empty tank and full tank.

Following the above maintenance measures can extend the service life of the VEGASON 61 and maintain measurement accuracy.

Summary

With non-contact measurement, wide range, and flexible output, the VEGASON 61 ultrasonic level transmitter is a reliable choice for industrial level measurement. Correct installation, commissioning, and maintenance are the keys to ensuring its long-term stable operation. For complete information, please download the VEGASON 61 Chinese manual.