Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

11362Z 电导式液位计

11362Z 电导式液位计

Double rod probe 11362Z

The 11362Z is a high resistant probe for applications requiring accurate point level detection or overfill prevention in plastic vessels or vessels made of non-conducting material. The two-point control can be carried out in vessels with electrically conducting walls.
Compare

Point Level / Liquids

Measuring Principle Conductive
Characteristic / Application Double rod probe with high-class media contacting wetted parts
Supply / Communication Relay
Ambient temperature -20 °C ... 80 °C
(-4 °F ... 176 °F)
Process temperature -40 °C ... 150 °C
(-40 °F ... 302 °F)
Process pressure / max. overpressure limit Vacuum ... 30 bar
(Vacuum ... 435 psi)
Min. conductivity of medium 20 µS/cm
Main wetted parts PTFE, PFA, 316 TI, Alloy B/C4, Titan, Tantal, Monel
Process connection G 1 1/2A
NPT1 1/2"
Flange DIN /ASME
Sensor length 0.1m ... 4m
(4ft ... 157ft)
Communication Relay
Certificates / Approvals ATEX, NEPSI
Components Transmitter: FTW325
Application limits Observe min medium conductivity

The 11362Z is a highly corrosion-resistant probe that can be used for limit detection and overflow protection in plastic vessels or vessels made of non-conductive materials. Two-point control is also possible via a conductive vessel wall.

 

Advantages

Various process connections selectable: thread G1 1/2 A (parallel thread) 

Thread 1 1/2" NPT (tapered thread) 

DIN standard flange, DN 40 to DN 200, PN 16 or PN 40, also optional tongue-and-groove flange

ANSI standard flange, 1 1/2" to 4", 150 psi or 300 psi, also optional clamp flange (only for 11362).

When using the Nivotester FTW325 probe for overflow protection, the EW 11Z electronic insert can be installed, providing continuous monitoring of the cable up to the maximum limit.

The 11362Z series can be used in hazardous explosive areas, Zone 0 of wastewater treatment plants (oil collection basins), and for overflow protection (WHG) of water-polluting liquids.

 

Areas of application

Limit detection: for limit detection and overflow protection in plastic tanks or tanks made of non-conductive materials. Two-point control: via the conductive outer wall of the tank.

 

 

E+H Product Configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products to compare in the boxes below (up to three products)

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source:Endress+Hauserwebsite public information

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Conductive Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Conductive.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Conductive for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Conductive Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Conductive.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Conductive for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Conductive Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Conductive.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Conductive for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Conductive Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Conductive.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Conductive for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.