Technical Data
ComparePoint Level / Liquids
| Measuring Principle | Conductive |
| Characteristic / Application | One rod probe. Simple rod shortening or rod change on location |
| Supply / Communication | Relay |
| Ambient temperature | -20 °C ... 120 °C (-4 °F ... 248 °F) |
| Process temperature | -10 °C ... 100 °C (+10 °F ... +210 °F) |
| Process pressure / max. overpressure limit | Vacuum ... 10 bar (Vacuum ... 145 psi) |
| Min. conductivity of medium | 20 µS/cm |
| Main wetted parts | PFA, 316TI |
| Process connection | G 1 1/2A set-in nozzle |
| Sensor length | 0.05 m ... 2 m (2" ... 79") |
| Communication | Relay |
| Components | Transmitter: FTW325 |
| Application limits | Observe min. medium conductivity |
The 11371 probe is used for limit detection of food-grade liquids such as milk, beer, fruit juice, etc. The probe is made of corrosion-resistant insulating material and has CIP/SIP functionality, making it highly suitable for the food industry.
Advantages
Rod probe made of corrosion-resistant insulating material (can also be used for measuring corrosive media)
Suitable for CIP cleaning and steam sterilization (no special cleaning steps required)
Various process connection forms selectable (optimized application compatibility)
Probe can be shortened as required (beneficial for inventory management)
Areas of application
For limit detection in tanks of food-grade liquids such as milk, beer, fruit juice, etc. The probe consists of the following parts:
Partially insulated sintered PFA stainless steel rod
Stainless steel weld-in or threaded connection
Gasket specially designed for food
Stainless steel housing
Cable gland M16, etc.
E+H Product Configurator
Please enter the product order code to configure
Product comparison
Please enter the order codes of the products to compare in the boxes below (up to three products)
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Source:Endress+Hauserwebsite public information
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Conductive Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Conductive.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Conductive for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Conductive Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Conductive.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Conductive for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Conductive Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Conductive.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Conductive for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Conductive Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Conductive.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Conductive for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Related Products
Endress+HauserLiquipoint T FTW31
Endress+HauserNivotester FTW325
Endress+HauserLiquipoint FTW23
Endress+HauserLiquipoint FTW33
Endress+HauserLiquipoint T FTW32
Endress+HauserOne rod probe 11375Z
Endress+HauserPump protection sensor FTW360
Endress+Hauser