Technical Data
CompareLiquids
| Measuring Principle | Ultrasonic flow |
| Product headline | std_productprofile_product_usp_8209. std_productprofile_product_usp2_58665_1571899493. std_productprofile_product_field_of_application_8210. |
| Sensor features | std_productprofile_product_benefits_8212. Long-term stable signal – maintenance-free permanent mounting from outside with coupling pads. Process transparency – diagnostic capability. std_successorproducts_product_differentiating_tech_features_58667_1571900174. Wide nominal diameter range: DN 15 to 4000 (½ to 160"). std_successorproducts_product_differentiating_tech_features_58669_1571900174. |
| Transmitter features | std_productprofile_product_benefits_8192. std_productprofile_product_benefits_8193. std_productprofile_product_benefits_58666_1571901005. std_successorproducts_product_differentiating_tech_features_58672_1571901893. std_successorproducts_product_differentiating_tech_features_58668_1571902040. std_successorproducts_product_differentiating_tech_features_58670_1571902090. |
| Nominal diameter range | Single channel, 1 or 2 paths : DN15 to 4000 (1/2 to 160") Dual channel, 1 or 2 paths : DN15 to 4000 (1/2 to 160") |
| Wetted materials | Clamp on system: Sensor holder 1.4308/CF-8 Sensor housing 1.4301/304 Strapping bands 1.4301/304 |
| Measured variables | Volume flow channel 1&2, average volume flow, volume flow difference, sound velocity, flow velocity, totalizer |
| Max. measurement error | Volume flow: ±3% o.r. for DN15 ±2% o.r. for DN25 to DN200 ±2% o.r. above DN200 |
| Measuring range | 0.3 to 10 m/s (1 to 33 ft/s) |
| Max. process pressure | N/A |
| Medium temperature range | DN15 to 65 -40 to +100°C (-40 +212 °F) -40 to +150°C (-40 +302 °F) option DN50 to 4000 -40 to +80°C (-40 +276 °F) -40 to +170°C (-40 +338 °F) option |
| Ambient temperature range | -20 to +60 °C (-4 to +140 °F) -40 to +60 °C (-40 to +140 °F) optional |
| Sensor housing material | N/A |
| Transmitter housing material | Wall-mounted housing: powder-coated die-cast aluminum |
| Degree of protection | IP67, type 4X for transmitter IP68 type 6P for sensors. Transmitter: IP67, type 4X enclosure |
| Display/Operation | 4 lines backlit display with three optical keys |
| Outputs | 1x 4-20 mA HART 1x Pulse/frequency/switch output (passive) |
| Inputs | N/A |
| Digital communication | HART PROFIBUS PA Profibus DP FOUNDATION Fieldbus |
| Power supply | 85 to 260 V AC 20 to 55 V AC 16 to 62V DC |
| Hazardous area approvals | ATEX, FM/CSA, NEPSI, JPN |
| Other approvals and certificates | Flowmeter verification for DN15, 25, 40, 50 & 100 only Marine certificate EAC marking |
| Product safety | EAC marking |
| Metrological approvals and certificates | Flowmeter verification for DN15, 25, 40, 50 & 100 only |
| Marine approvals and certificates | Marine certificate |
Advantages
Automatic frequency scan for optimum measuring performance
Safety design for the chemical and petrochemical industries - international explosion protection approvals
No leaks - measurement takes place directly outside the pipe
High process transparency - diagnostic functions
Optimum performance - extended functions and diagnostic software
Flexible data transmission - a choice of communication methods
Automatic data recovery for service purposes
Application areas
Choice of measuring principle not limited by pressure, density, temperature, conductivity and viscosity
Clamp-on installation, ideal for measuring chemicals, solvents, liquid hydrocarbons, acids and alkalis
Instrument features
Medium temperature: –40~ 170 °C (–40~ 338 °F)
Nominal diameter: DN 15 ~ 4000 (1/2 ~ 160")
Flowmeter installation has no effect on the process
Aluminum transmitter housing
Four-line backlit display, touch control
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus
E+H Product Model Configurator
Please enter the product model to configure
Product comparison
Please enter the product models to compare in the input fields below; up to three products can be compared
Technical documentation
Technical data
Documents / Manuals / Software
Accessories / Spare parts
Source:Endress+Hauserpublic information from the website
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Ultrasonic Flow Meter Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Ultrasonic Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Ultrasonic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Ultrasonic Flow Meter Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Ultrasonic Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Ultrasonic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Ultrasonic Flow Meter Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Ultrasonic Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Ultrasonic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Ultrasonic Flow Meter Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Ultrasonic Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Ultrasonic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.