Prosonic Flow 93T portable
Technical Data
CompareLiquids
| Measuring Principle | Ultrasonic flow |
| Product headline | Portable volume flowmeter for measurement of liquid applications; from outside of the pipe with "Clamp On" sensors |
| Sensor features | Integrated USB data logging |
| Nominal diameter range | DN 15...65 - 1/2"...2 1/2" (-40...+100°C or -40...+150 °C) DN 50...300 - 2"...12" -40...+80 °C or 0...+170 °C) DN 100...4000 - 4"...160" (-40...+80 °C) |
| Max. measurement error | +/-2.0 % |
| Measuring range | 0....452'389 m3/h |
| Max. process pressure | No limit |
| Medium temperature range | DN 15...65 -40...+150°C (-40...+302°F) DN 50...300 -40...+170°C (-40...+338°F) DN 100...4000 -40...+80°C (-40...+176°F) |
| Degree of protection | IP 40 |
| Display/Operation | Four line backlit touch control |
| Outputs | Integrated data logger/site manager Easy data transfer via USB stick without additional software |
| Inputs | 4...20mA |
| Digital communication | FXA 193 |
The portable ultrasonic flowmeter Prosonic Flow 93T is designed specifically for temporary monitoring and test measurements with clamp-on sensors and can operate independently on battery power without an external power supply. The Prosonic Flow 93T is the ideal tool for verifying existing flow measuring points.
Advantages
Automatic frequency scanning optimizes performance
Fast and secure installation - with a specially designed mounting kit
No leakage - measurement directly on the outside of the pipe
High process transparency - with diagnostic function
Temporary monitoring of measuring points - portable flowmeter with rechargeable battery and current output
Verification of other flow measuring devices - built-in data logger and current input
Automatic data recovery function
E+H Product Configurator
Please enter the product order code to configure
Product comparison
Please enter the order codes of the products to compare in the boxes below (up to three products)
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Measuring principle video
Source:Endress+Hauserwebsite public information
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Ultrasonic Flow Meter Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Ultrasonic Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Ultrasonic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Ultrasonic Flow Meter Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Ultrasonic Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Ultrasonic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Ultrasonic Flow Meter Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Ultrasonic Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Ultrasonic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Ultrasonic Flow Meter Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Ultrasonic Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Ultrasonic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.