CLD132 Conductivity compact device

CLD132  Conductivity compact device

Smartec S CLD132

Configurable Models 20 models
Inductive conductivity measuring system for applications with fast temperature changes
Compare

Conductivity

Measuring Principle Inductive
Application - Alkali/acid concentration control - phase separation in pipe systems - monitoring and control of bottle cleaning systems - product monitoring in breweries, dairies and the beverage industry - CIP system control
Characteristic Compact measuring system for an inductive conductivity measurement special made for media with a high conductivity.
Measuring range 100 µS/cm - 2000 mS/cm
Measuring principle Inductive measuring system including transmitter and sensor.
Design Compact transmitter made of stainless steel with an inductive sensor made of PEEK in a separate or compact version.
Material Housing: Stainless steel 1.4301 polished Window: Polycarbonate Sensor: PEEK, stainless steel 1.4435 Sealing: Chemraz
Process temperature max. 140°C (max. 30 min.)
284°F (max. 30 min.)
Process pressure max. 12 bar (90°C)
(174 psi(194°F))
Temperature sensor Pt100
Ex certification No
Ingress protection IP67
Input One-channel transmitter incl. temperature.
Output / communication Conductivity and temperature 0/4-20 mA, HART, Profibus.

Field of application
Smartec CLD132 is a measuring system for inductive conductivity. The combination of a transmitter and a sensor is interference-free, easy-to-use and features a stainless steel temperature sensor that gives you an ultrafast temperature response for reliable measurement in separation applications.
Smartec CLD132 is suited to applications such as:
Alkaline/acid concentration control in remaking
Phase separation of product/water and product/product mixtures in pipe systems
Product monitoring
Smartec CLD132 features the following protocols and interfaces:
0/4...20mA
HART
PROFIBUS DP
PROFIBUS PA

Benefits
Engineered for quick temperature response
Low risk of soiling due to encapsulated sensor
Insensitive to polarization

 

Conductivity:

Measuring Principle Inductive
Application - Alkali/acid concentration control - phase separation in pipe systems - monitoring and control of bottle cleaning systems - product monitoring in breweries, dairies and the beverage industry - CIP system control
Characteristic Compact measuring system for an inductive conductivity measurement special made for media with a high conductivity.
Measuring range 100 µS/cm - 2000 mS/cm
Measuring principle Inductive measuring system including transmitter and sensor.
Design Compact transmitter made of stainless steel with an inductive sensor made of PEEK in a separate or compact version.
Material Housing: Stainless steel 1.4301 polished Window: Polycarbonate Sensor: PEEK, stainless steel 1.4435 Sealing: Chemraz
Process temperature max. 140°C (max. 30 min.)
284°F (max. 30 min.)
Process pressure max. 12 bar (90°C)
(174 psi(194°F))
Temperature sensor Pt100
Ex certification No
Ingress protection IP67
Input One-channel transmitter incl. temperature.
Output / communication Conductivity and temperature 0/4-20 mA, HART, Profibus.
Model Name
CLD132-SVA138AA1 电导率仪
CLD132-PVA138PF1 电导率仪
CLD132-PSMS38PP1 电导率仪
CLD132-PMV138PF1 电导率仪
CLD132-PVA138PP1 电导率仪
CLD132-PVA138PE1 电导率仪
CLD132-PSMS38HB1 电导率仪
CLD132-PSMS38PP1 电导率仪
CLD132-PMV138AA1 电导率仪
CLD132-PCS138PP1 电导率仪
CLD132-PMV138HB1 电导率仪
CLD132-PSMS38PE1 电导率仪
CLD132-SCS138AA1 电导率仪
CLD132-SMV138AA1 电导率仪
CLD132-PCS138HB1 电导率仪
CLD132-PCS138PE1 电导率仪
CLD132-SSMS38AA1 电导率仪
CLD132-PCS138PF1 电导率仪
CLD132-PMV138PE1 电导率仪
CLD132-PSMS38PF1 电导率仪
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Conductivity Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Conductivity.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Conductivity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Conductivity Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Conductivity.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Conductivity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Conductivity Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Conductivity.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Conductivity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Conductivity Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Conductivity.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Conductivity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.