Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

CLM223 电导率变送器

CLM223 电导率变送器

Liquisys M CLM223

Configurable Models 20 models
Liquisys CLM223 is a standard transmitter for all analog conductivity sensors. It improves your operational safety thanks to continuous plausibility, process and sensor checks. Select from numerous hardware and software modules, such as relays or fieldbus communication, to adapt it exactly to your measuring task. This modularity also allows you to upgrade the transmitter at any time. A simple menu and calibration make configuration and operation fast and easy.
Compare

Conductivity

Measuring Principle Conductive
Application Water, waste water, process
Characteristic 4-wire transmitter with a two-line display.
Design Panel-mounted transmitter for conductivity
Dimension 96x96 mm, built-in-depth: 146 mm
Temperature sensor Display and current output
Ex certification No
Ingress protection IP54
Input 1-channel transmitter
Output / communication 0/4-20 mA, Hart, Profibus.
Certificates, declarations and approvals CSA Gen. Purpose

The Liquisys CLM223 is a standard transmitter for all analog conductivity sensors. Thanks to continuous plausibility checks and checks of the measuring process and the sensor, it increases operating safety. Whichever hardware and software modules are selected, e.g. relays and bus communication, it adapts perfectly to the measuring task. It also allows the transmitter to be upgraded at any time, and its simple menus and factory calibration make configuration and operation fast and convenient.

 

Benefits

Higher operating safety: continuous process check system, user-defined alarm settings and calibration plausibility check

Extensive functions: conductivity, resistivity and concentration measurement, ultrapure water monitoring in accordance with USP and EP standards

Convenient operation and service: intuitive user interface, simple calibration and manual contact control

Reduced maintenance effort: automatic cleaning triggered by alarms and limit switches (with Chemoclean)

Suitable for a wide range of applications: various extension options, such as P(ID) controllers, timers, etc., for all processes (conductive sensors)

 

Application areas

The Liquisys CLM223 transmitter can be used with various analog conductivity sensors and is suitable for non-hazardous-area measurement in the following industries and utilities:

 

Chemical industry

Food & Beverage

Life sciences sector

Power & Energy

Water & Wastewater

Primary raw materials & metallurgy

The Liquisys CLM223 uses the following communication protocols and interfaces:

 

0/4...20 mA

HART

PROFIBUS DP

PROFIBUS PA

 

E+H product model configurator

Please enter the product model to configure

Product comparison

Please enter the product models to be compared in the input boxes below; up to three products can be compared

 

   

Technical information

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

A

Source: public information from the Endress+Hauser website

Model Name
CLM223-CD0005 电导率变送器
CLM223-ID0005 电导率变送器
CLM223-ID8610 电导率变送器
CLM223-CD0105 电导率变送器
CLM223-ID0105 电导率变送器
CLM223-CD8605 电导率变送器
CLM223-CD8510 电导率变送器
CLM223-CS8326 电导率变送器
CLM223-ID8320 电导率变送器
CLM223-IS0405 电导率变送器
CLM223-CS8105 电导率变送器
CLM223-CD8615 电导率变送器
CLM223-IS0126 电导率变送器
CLM223-IS0505 电导率变送器
CLM223-IS0625 电导率变送器
CLM223-IS8025 电导率变送器
CLM223-IS0326 电导率变送器
CLM223-IS8016 电导率变送器
CLM223-CD0505 电导率变送器
CLM223-CS0605 电导率变送器
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Conductivity Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Conductivity.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Conductivity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Conductivity Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Conductivity.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Conductivity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Conductivity Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Conductivity.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Conductivity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Conductivity Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Conductivity.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Conductivity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.