Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

CLS52 电导率传感器

CLS52 电导率传感器

Indumax CLS52

Configurable Models 12 models
The Indumax CLS52 inductive conductivity sensor is equipped with a stainless steel temperature sensor that gives you an ultrafast temperature response to measure exactly in separation applications.
Compare

Conductivity

Measuring Principle Inductive
Application Food, pharmaceuticals
Characteristic Hygienic inductive measuring cell for conductivity measurements, concentration control, CIP-control, cleaning and phase separation.
Measuring range 0.1 to 2000 mS/cm
Measuring principle Inductive conductivity measurement.
Design Hygienic inductive conductivity cell with an outside temperature sensor for a faster temperature reading.
Material Sensor: PEEK
Heat contact nut: stainless steel 1.4435
Sealing: Chemraz
Dimension Coil: outside diameter: appr. 47 mm inside diameter: appr. 15 mm
Process temperature Max. 125°C (short time up to 140°C)
max. 257°F (short time up to 284°F)
Process pressure Max. 16 bar at 90 °C
(Max. 232 psi at 194 °F)
Temperature sensor Integrated Pt100 in a heat contact nut
Ex certification not available as Ex version
Connection Process connections: dairy fitting, Clamp, thread 1,5", Varivent, APV, Perlick, SMS cable: fixed cable connection.
Ingress protection IP67
Certificates, declarations and approvals Calibration certification.

The CLS52 inductive conductivity sensor is used in the food and beverage industry to protect products and production processes. In separated measurement applications, a stainless steel temperature sensor provides ultra-fast temperature response for precise measurement.

 

Advantages

Fast temperature response

Hygienic design prevents contamination

Suitable for CIP and SIP cleaning

Encapsulated sensor construction prevents contamination

Insensitive to polarization

 

Areas of application

The Indumax CLS52 is used for toroidal conductivity measurement, especially in food&beverage applications requiring fast temperature response, e.g.:

 

Acid/alkali concentration control during preparation

Separation between medium/water and medium/medium mixtures in pipes

Monitoring and control of bottle washing systems

Product monitoring in breweries, dairies and the beverage industry

CIP system control

 

 

E+H Product Configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products to compare in the boxes below (up to three products)

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

A

Source:Endress+Hauserwebsite public information

Model Name
CLS52-A1CS1A1 电导率传感器
CLS52-A1SMSA2 电导率传感器
CLS52-A1MV1A1 电导率传感器
CLS52-A1MV1A2 电导率传感器
CLS52-A1CS1A3 电导率传感器
CLS52-A1VA1A1 电导率传感器
CLS52-A1VA1A3 电导率传感器
CLS52-A1CS1A2 电导率传感器
CLS52-A1SMSA1 电导率传感器
CLS52-A1SMSA3 电导率传感器
CLS52-A1VA1A2 电导率传感器
CLS52-A1MV1A3 电导率传感器
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Conductivity Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Conductivity.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Conductivity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Conductivity Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Conductivity.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Conductivity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Conductivity Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Conductivity.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Conductivity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Conductivity Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Conductivity.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Conductivity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.