Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

CPF81E PH电极

CPF81E PH电极

Memosens CPF81E

Configurable Models 4 models
Memosens CPF81E is the digital, robust solution for harsh environments. It measures reliably and accurately even in abrasive media and at high flow rates. With its integrated assembly, the electrode saves installation space. Thanks to Memosens 2.0 digital technology, CPF81E combines maximum process integrity with simple operation. It resists moisture and enables lab calibration. It offers extended storage of calibration and process data providing the perfect basis for predictive maintenance.
Compare

pH

Measuring Principle Potentiometric
Application Flotation, leaching, neutralization, outlet monitoring
Characteristic Resistent against electrolyte poisoning and dirt repellent gel-electrode including process connection NPT 3/4"
Measuring range pH 0 to 14
Measuring principle Gel-compact electrode with double chamber reference system, kalium nitrate bridge electrolyte and PTFE-diaphragm
Design Compact electrode in PPS housing with NPT 3/4" process connection
Material Housing: PPS
pH electrode: lead-free membrane glass
Double chamber reference system: KNO3 and KCl/AgCl
Dimension Diameter: 22 mm (0.87 inch)
Length (protcetion guard, long shaft): 150 mm (5.91 inch)
Length (flat membrane): 140 mm (5.51 inch)
Process temperature Version LH: 0 to 110 °C (32 to 230 °F)
Version NN: 0 to 80 °C (32 to 170 °F)
Process pressure 1 to 10 bar abs at 80 °C
(15 to 145 psi at 176 °F)
Temperature sensor NTC 30K
Ex certification (optional) FM IS NI Cl. I Div.1&2, Groups A-D
Connection Memosens plug
Ingress protection IP68

The Memosens CPF81E is a digital pH electrode that is robust and measures pH values stably under demanding conditions. Measurement is completely unaffected even by corrosive media and high-flow media. The electrode has its own holder and requires little installation space. The CPF81E uses Memosens 2.0 digital technology with high process integrity and very simple operation. The electrode is waterproof and moisture-proof and allows laboratory calibration. It supports extended data storage for calibration and process parameters, making it the perfect basis for predictive maintenance.

Benefits
Memosens 2.0 supports an extended storage unit for calibration and process parameters, enabling better trend identification and providing the perfect basis for future predictive maintenance and improved IIoT services.

High long-term stability: double-junction design for better protection against ion toxic diffusion, e.g. S2- or CN-.

Robust polymer housing effectively prevents mechanical damage.

The optional flat membrane allows measurement in high-flow and abrasive media.

Non-contact inductive signal transmission for high process safety.

Minimizes production downtime, extends electrode service life and reduces operating costs.

Applications
The Memosens CPF81E pH electrode is robust and suitable for mining industry applications as well as water and wastewater treatment. It reliably monitors:

Flotation processes

Leaching processes

Neutralization processes

Inlet and outlet

Approved by CSA C/US for use in explosion-protection zones 0, 1 and 2.

 

E+H Product Model Configuration Tool

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the fields below; up to three products can be compared

 

   

Technical documentation

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

A

A

Source: Endress+Hauserpublic information from the website

Model Name
CPF81E-AA5LAD1 pH electrode
CPF81E-AA5LAD2 PH电极
CPF81E-AA5LAD3 PH电极
CPF81E-AA5NAD1|CPF81E-10E3/0 PH电极
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · pH Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of pH.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable pH for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · pH Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of pH.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable pH for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · pH Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of pH.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable pH for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · pH Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of pH.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable pH for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.