Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

CPS42D

CPS42D

Ceraliquid CPS42D

Memosens glass electrode, used for measuring rapidly changing dielectric composition or low conductivity media
Compare

ORP / Redox

Measuring Principle
Application - Special applications with high requirements with regard to accuracy, speed.- rapidly changing composition of media, highly clogging media, low conductivities.
Characteristic - Digital electrode with Memosens technology - gel-free, refillable electrolyte - greatest accuracy - can be subject to pressure to prevent clogging
Measuring range -1500 mV - +1500 mV
Measuring principle - Liquid filled compact electrode with ceramic diaphragm - platinum ring
Dimension Diameter: 12 mm
Shaft lengths: 120, 225 mm
Process temperature -15°C - 130°C
Process pressure max. 8bar
Ex certification ATEX
FM
CSA
Connection Inductive transfer of digital signals.
Ingress protection IP68
Certificates, declarations and approvals EHEDG

ORP / Redox:

Measuring Principle Sensor ORP / Redox
Application - Special applications with high requirements with regard to accuracy, speed.- rapidly changing composition of media, highly clogging media, low conductivities.
Characteristic - Digital electrode with Memosens technology - gel-free, refillable electrolyte - greatest accuracy - can be subject to pressure to prevent clogging
Measuring range -1500 mV - +1500 mV
Measuring principle - Liquid filled compact electrode with ceramic diaphragm - platinum ring
Dimension Diameter: 12 mm
Shaft lengths: 120, 225 mm
Process temperature -15°C - 130°C
Process pressure max. 8bar
Ex certification ATEX
FM
CSA
 
Connection Inductive transfer of digital signals.
Ingress protection IP68
Additional certifications EHEDG
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · ORP Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of ORP.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable ORP for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · ORP Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of ORP.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable ORP for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · ORP Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of ORP.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable ORP for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · ORP Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of ORP.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable ORP for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.