Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

CPS71D Digital pH sensor

CPS71D  Digital pH sensor

Tophit CPS471D

Endress+Hauser CPS471D
Configurable Models 3 models
Memosens glass electrode for the chemical and life sciences industries
Compare

pH

Measuring Principle
Application Hygienic and sterile applications, food industry, pharmaceutical industry, biotechnology
Characteristic Sterilizable and autoclavable ISFET sensor for the pH measurement
Analog or digital sensors with Memosens technology
Measuring range pH 0 to 14
Measuring principle Ceramic diaphragm, double chamber reference, double gel
Design All shaft lengths with temperature sensor
Advanced gel technology
Material PEEK, Ceramics und EPDM
Dimension Diameter: 12 mm (0.47 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.72, 8.86, 14.2 and 16.7 inch)
Process temperature –15 to 135 °C
(5 to 275 °F)
Process pressure Max. 10 bar at 100 °C
(Max. 145 psi at 212 °F)
Temperature sensor Pt1000
Ex certification ATEX, FM, CSA
Connection Contactless, inductive, digital connection head with Memosens technology
Ingress protection IP68

Field of application
Ceragel CPS71D is the digital specialist for demanding processes and hygienic applications. Its contamination-resistant gel guarantees stable measurement even in flowing media or low conductivity. The sensor measures reliably at high temperatures and is non-toxic assuring highest safety. Ceragel CPS71D is not the latest Memosens generation. To get information on the new Memosens sensors with extended functionality, click CPS71E for chemical applications and CPS61E for hygienic applications.
Process technology and monitoring of processes with:
- Quickly changing pH values
- High proportion of electrode poisons such as H2S
Chemical industry
Hygienic and sterile applications:
- Fermenters
- Biotechnology
- Life sciences
With ATEX, FM, and CSA approval for application in hazardous areas

Benefits
Sensor resists strong acids and bases and high organic loads
Suitable for CIP/SIP and autoclaving maintaining high accuracy
Free from animal-based materials and from acrylamide
Maximum process safety through non-contact inductive signal transmission
Enables predictive maintenance due to storage of sensor and process-specific data
Reduced operating costs thanks to minimized process downtime and extended sensor lifetime

 

pH:

Measuring Principle Potentiometric
Application Aggressive chemical and hygienic applications, process
Characteristic Analog, digital pH single-rod measuring cells
For chemical process, hygienic and sterile applications with an ion trap for poison-resistant reference
Measuring range pH 0 to 14
Measuring principle Ceramic diaphragm, ion-trap
Design All shaft lengths with temperature sensor
Advanced gel technology
Digital electrode with Memosens technology
Material Glass and ceramic
Dimension Diameter: 12 mm (0.47 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.72, 8.86, 14.2 and 16.7 inch)
Process temperature 0 to 140 °C (32 to 284 °F)
Process pressure 1 to 14 bar (15 to 203 psi)
Temperature sensor NTC 30k
Ex certification ATEX, FM, CSA
Connection Inductive, digital connection head with Memosens technology
Ingress protection IP68
Additional certifications 3A, biocompatibility
Model Name
CPS471D-7211 pH电极
CPS471D-721G pH电极
CPS471D-741G pH电极
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · pH Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of pH.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable pH for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · pH Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of pH.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable pH for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · pH Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of pH.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable pH for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · pH Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of pH.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable pH for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.