Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

CPS91E Digital pH sensor

CPS91E  Digital pH sensor

Memosens CPS91E

Configurable Models 5 models
Memosens 2.0 pH electrode for heavily soiled media in chemical processes, paper or paint production
Compare

pH

Measuring Principle Potentiometric
Application • Chemical processes
• Pulp and paper industry
• Flue gas cleaning
• Contaminated media:
• Solids
• Emulsions
• Precipitation reactions
Characteristic Digital pH electrodes with open aperture for contaminated media and integrated temperature sensor
Measuring range 0 to 14 pH
Measuring principle Gel compact electrode wit open aperture and double gel reference
Design All shaft lengths with temperature sensor
Advanced gel technology
Material Sensor shaft: Glass to suit process
pH membrane glass:Type B
Metal lead: Ag/AgCl
O-ring: FKM
Process coupling: PPS fiber-glass reinforced
Nameplate: Ceramic metal oxide
Dimension Diameter: 12 mm (0.47 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.72, 8.86, 14.17 and 16.73 inch)
Process temperature 0 to 110 °C (32 to 230 °F)
Process pressure 0.8 to 14 bar (11.6 to 203 psi) absolute
Temperature sensor NTC 30K
Ex certification With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
hazardous areas Zone 0, Zone 1 and Zone 2.
Connection Inductive, contactless connection head with Memosens 2.0 technology
Ingress protection IP68

Field of application
Memosens CPS91E is equipped with Memosens 2.0 digital technology, offering enhanced data storage for predictive maintenance and IIoT. The sensor features an open aperture that prevents fouling and ensures the most reliable measurement in fibrous media or media with a high content of suspended solids such as dispersions, precipitations or emulsions. Memosens CPS91E is completely resistant to moisture and can be pre-calibrated in the lab which facilitates operation and improves process integrity.
Chemical processes
Pulp and paper industry
Contaminated media and suspended solids
- Dispersions
- Precipitations
- Emulsions
With ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.

 

Benefits
Reliable measurement in heavily soiled media: Open aperture cannot be blocked by fibres or suspended solids.
Not affected by fluctuations in pressure and temperature: Thanks to open aperture no diffusion potential can build up at the junction.
Stabilized gel filling allows for low maintenance and a long sensor lifetime.
Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services.
Non-contact, inductive signal transmission eliminates disturbances caused by moisture or corrosion, ensuring highest process safety.
Lab calibration and quick sensor exchange in the process maximize process uptime and reduce operating costs.

 

pH:

Measuring Principle Potentiometric
Application - Process applications - media with high contamination: emulsions, suspensions, precipitation reactions - min. conductivity >500µS/cm.
Characteristic - rapid response - new, stabilised gel insensitive to contaminations
Measuring range pH 0-14
Measuring principle - Open aperture - double gel reference
Design - all shaft lengths with temperature sensor - advanced gel technology
Material Glass
Dimension Diameter: 12 mm (0.46 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.68, 8.77, 14.04 and 16,57 inch)
Process temperature max. 110°C
(230°F)
Process pressure max. 10 bar
(145 psi)
Temperature sensor Optional with integrated Pt100 or Pt1000.
Ex certification Simple operational equipment, no certification necessary.
Connection TOP68 plug-in head
Ingress protection IP68
Model Name
CPS91E-AA7BTH2 pH电极
CPS91E-AA7BHH2 pH电极
CPS91E-NA7BHH2 pH电极
CPS91E-BA7BTH2 pH电极
CPS91E-NA7BTH2 pH电极
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · pH Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of pH.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable pH for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · pH Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of pH.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable pH for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · pH Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of pH.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable pH for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · pH Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of pH.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable pH for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.