Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

CPS97E Digital non-glass pH sensor

CPS97E  Digital non-glass pH sensor

Memosens CPS97E

Configurable Models 11 models
Memosens 2.0 ISFET pH sensor for polluted media in chemical processes, paper or pigment production
Compare

pH

Measuring Principle ISFET
Application Unbreakable pH sensor for use in highly polluting media:
-Chemical industry
-Pulp and paper industry
-Mineral and metal industry
Characteristic Digital pH electrodes for with open aperture for clogging media e.g. suspended solides, dispersion, precipitation reaction
Needs min. conductivity of >500µS/cm
Reference Stabilized gel reference system
Measuring range pH 0 to 14
Material Sensor shaft: PEEK
Sealings: FFKM
Metal lead: Ag/AgCl
O-ring: FKM
Process coupling: PPS fiber-glass reinforced
Nameplate: Ceramic metal oxide
Dimension Diameter: 12 mm (0.47 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.72, 8.86, 14.2 and 16.7 inch)
Process temperature -15 to 110 °C (5 to 230 °F)
Process pressure Max. 11 bar abs. at 100 °C
(Max. 159.5 psi at 212 °F)
Temperature sensor Pt1000
Ex certification With the following approvals for use in potentially explosive areas of Zone 0, Zone 1 and Zone 2: ATEX, IECEx, CSA C / US, NEPSI, JPN Ex, INMETRO,
UKCA and Korea Ex
Connection Inductive, contactless connection head with Memosens 2.0 technology
Ingress protection IP 68

Field of application
Memosens CPS97E is the expert for media with a high content of fibres or suspended solids such as dispersions, precipitations and emulsions. Its unbreakable shaft and the open aperture guarantee reliable measurement under harsh process conditions. CPS97E features Memosens 2.0 digital technology, offering extended storage of calibration and process data for predictive maintenance. The sensor resists moisture and enables lab calibration, enhancing process integrity and increasing process uptime.
Chemical processes
Contaminated media and suspended solids
- Dispersions
- Precipitation
- Emulsions
Pulp and paper industry

Benefits
Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services.
Unbreakable: PEEK sensor body withstands harsh conditions ensuring product safety
Open aperture prevents blocking of the sensor even in media with a high dirt load.
Chemically stable reference gel assures long-term stable measurements
Low maintenance: ISFET technology is insensitive to high temperature or temperature changes which results in long calibration intervals
Maximum process safety: Non-contact, inductive signal transmission eliminates all problems caused by moisture or corrosion.

 

pH:

Measuring Principle ISFET
Application Unbreakable pH sensor for use in highly polluting media:
-Chemical industry
-Pulp and paper industry
-Mineral and metal industry
Characteristic Digital pH electrodes for with open aperture for clogging media e.g. suspended solides, dispersion, precipitation reaction
Needs min. conductivity of >500µS/cm
Reference Stabilized gel reference system
Measuring range pH 0 to 14
Material Sensor shaft: PEEK
Sealings: FFKM Metal lead: Ag/AgCl
O-ring: FKM
Process coupling: PPS fiber-glass reinforced
Nameplate: Ceramic metal oxide
Dimension Diameter: 12 mm (0.47 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.72, 8.86, 14.2 and 16.7 inch)
Process temperature -15 to 110 °C (5 to 230 °F)
Process pressure Max. 11 bar abs. at 100 °C
(Max. 159.5 psi at 212 °F)
Temperature sensor Pt1000
Ex certification With the following approvals for use in potentially explosive areas of Zone 0, Zone 1 and Zone 2: ATEX, IECEx, CSA C / US, NEPSI, JPN Ex, INMETRO, UKCA and Korea Ex
Connection Inductive, contactless connection head with Memosens 2.0 technology
Ingress protection IP 68
Model Name
CPS97E-AA8BHH2 非玻璃PH电极
CPS97E-BA8BHH2 非玻璃PH电极
CPS97E-NA8BHH2 非玻璃PH电极
CPS491D-722G 非玻璃PH电极
CPS491D-7221 非玻璃PH电极
CPS97E-AA8BHH9 非玻璃PH电极
CPS97E-GR8BHH2 非玻璃PH电极
CPS97E-GR8BHH4 非玻璃PH电极
CPS97E-GA8BHH2 非玻璃PH电极
CPS97E-10M7/0 非玻璃PH电极
CPS97E-GA8BHH4 非玻璃PH电极
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · pH Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of pH.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable pH for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · pH Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of pH.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable pH for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · pH Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of pH.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable pH for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · pH Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of pH.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable pH for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.